Impeller quick estimate
The impeller quick estimate takes the main impeller geometry and speed and, within seconds, estimates the head, efficiency, shaft power and NPSHr curves together with a set of key indicators. Use it for preliminary selection and for comparing different impeller designs; a design you are happy with can be saved as a private model and then used in searches, Filter Search and duty simulation. This chapter covers every impeller parameter, the estimation method and formulas, each key indicator, comparison and saving, and the various warnings and error messages. The page is under “Impeller quick estimate” in the left Workspace.
Requirements and access
Premium
The impeller quick estimate requires signing in and is a Premium feature. When a regular user opens it, ““Impeller quick estimate” is a Premium feature” and a “Get Premium” button are shown. See Membership and curve watermarks.
Difference from Hydraulic design
The impeller quick estimate predicts performance from a known geometry; enterprise teams can also use Hydraulic design, which derives the impeller and volute geometry from the duty and exports drawings. The banner at the top of this page opens Hydraulic design directly.
How to open
Click “Impeller quick estimate” in the left Workspace.
The “Impeller quick estimate” button at the top of the Private models page.
Page layout
Left: the “Impeller geometry” panel and the impeller sketch.
Middle: the “Estimated performance curves” chart, with the “Print”, “Pin as reference” and “Save as private model” buttons below it, followed by the list of pinned designs for comparison.
Right: “Key indicators”, the list of warnings and the accuracy note.
After you change any parameter, the estimate is recalculated automatically after about 0.35 seconds; if this takes longer than about 0.4 seconds, “Calculating” is shown on the chart. The most recently entered parameters are saved in this browser and restored automatically the next time you open the page.
Impeller geometry
Enter each parameter in its input box: type directly, or use the up/down arrows on the right to change it by one step. Values outside the input box's range are clamped to the range automatically; if a combination of parameters is not reasonable, an error message is shown; see Error messages.
Impeller outlet diameter D2
The outer diameter of the impeller at the blade outlet.
Unit: mm
Default / range: 250; 50–3000, step 1.
Effect on the curve: determines the tip peripheral velocity u2 = π·n·D2/60. Head is roughly proportional to D2², and flow roughly proportional to D2 (with outlet width and inlet diameter unchanged).
Outlet width b2
The width of the flow passage between the two shrouds at the impeller outlet.
Unit: mm
Default / range: 18; input box 1–500, step 0.5; the valid range is greater than 0 and not more than 30% of D2.
Effect on the curve: the larger b2, the larger the outlet flow area and the lower the outlet radial velocity at a given flow; the head curve becomes flatter and the head at high flow becomes higher. A note is given when b2/D2 exceeds 0.15.
Number of blades Z
The number of impeller blades.
Default / range: 6; 2–12, step 1.
Effect on the curve: the more blades, the smaller the slip and the higher the head; slurry pumps commonly use 3–5 blades to ensure solids passage.
Outlet blade angle β2
The angle between the blade tangent and the circumferential direction at the blade outlet.
Unit: °
Default / range: 25; 10–90, step 0.5.
Effect on the curve: the larger β2, the higher the theoretical head and the flatter the head curve. When β2 exceeds 45°, the curve tends to show a hump (shut-off head lower than the head at intermediate flows), and a note is given. Typical centrifugal pumps use 15°–40°.
Blade inlet diameter D1
The diameter at which the blade leading edges lie (impeller eye diameter).
Unit: mm
Default / range: 120; input box 10–2500, step 1; the valid range is greater than 0 and less than 95% of D2.
Effect on the curve: together with β1 and the hub diameter it determines the inlet flow area and the shockless flow, and thus the BEP flow; it also affects NPSHr (the larger D1, the lower the inlet meridional velocity but the higher the inlet peripheral velocity). A note is given when D1/D2 exceeds 0.75.
Hub diameter
The diameter of the hub at the impeller inlet; 0 means no hub (common for overhung impellers).
Unit: mm
Default / range: 35; input box 0–1000, step 1; the valid range is less than 90% of D1.
Effect on the curve: the hub takes up part of the inlet area; the larger the hub, the smaller the shockless flow and the larger the NPSHr.
Inlet blade angle β1
The angle between the blade tangent and the circumferential direction at the blade inlet.
Unit: °
Default / range: 17; 8–45, step 0.5.
Effect on the curve: the larger β1, the larger the shockless (design) flow; the BEP moves towards higher flow.
Speed (Impeller geometry)
The impeller speed.
Unit: r/min
Default / range: 1480; 100–10000, step 10.
Effect on the curve: by the affinity laws, flow ∝ n, head ∝ n², power ∝ n³.
Fluid density
The density of the pumped fluid.
Unit: kg/m³
Default / range: 1000; 500–3000, step 10.
Effect on the curve: affects only the shaft power (proportional to density); it does not affect the head (m of liquid) or the shape of the efficiency curve.
Reset to defaults
The link to the right of the “Impeller geometry” title resets all parameters to the default values listed above.
Impeller sketch
The sketch below the parameters is drawn from the current parameters: the outer circle is D2, the dashed circle is D1 and the small grey circle is the hub; the number of blades and the outlet curvature change with Z and β2, and the values of D2, D1, b2, Z and β2 are labeled on the right. The sketch is only for checking the parameter proportions visually; it is not drawn from a real blade profile.
Estimation method
The estimate uses the one-dimensional design method for centrifugal pumps: the Euler equation gives the theoretical head, a slip factor corrects for the finite number of blades, and the individual losses are then deducted. In the symbols below, Q is the flow (m³/s) and g = 9.81 m/s².
Peripheral velocity
u2 = π × n × D2 / 60
u1 = π × n × D1 / 60
Example (hypothetical numbers): D2 = 250 mm, n = 1480 r/min, u2 = π × 1480 × 0.25 / 60 ≈ 19.4 m/s.
Calculating the slip factor
The Wiesner formula, multiplied by 0.92 to account for non-uniform outlet flow:
σ = 0.92 × (1 − √(sin β2) / Z^0.7)
Example (hypothetical numbers): β2 = 25°, Z = 6, √(sin 25°) ≈ 0.650, 6^0.7 ≈ 3.51, σ ≈ 0.92 × (1 − 0.185) ≈ 0.749.
Flow area and shockless flow
Blade blockage is accounted for by taking 90% of the flow area:
A2 = π × D2 × b2 × 0.9
A1 = π / 4 × (D1² − Dh²) × 0.9
Shockless flow Qs = A1 × u1 × tan β1
Qs is the flow through the impeller when the inlet flow angle exactly equals the blade angle (no pre-swirl). After deducting leakage, the corresponding flow at the pump outlet is the design flow Qd = Qs − QL (QL is described in the next section).
Theoretical head
Hth(Q) = u2 × (σ × u2 − Q / (A2 × tan β2)) / g
Leakage and volumetric efficiency
The volumetric efficiency is estimated from the specific speed; the leakage is independent of flow:
ηv = 1 / (1 + 0.3 × nq^(−2/3)), limited to 85%–99.5%
Leakage QL = Qs × (1/ηv − 1)
Impeller flow Qi = Q + QL
Design flow Qd = Qs − QL
Here nq is a specific speed estimated from the shockless flow Qs and 0.85 times the theoretical head; it differs slightly from the nq in “Key indicators”, which is calculated from the actual BEP.
Hydraulic losses and the head curve
H(Q) = Hth(Qi) − kf × Qi² − ks × (Qi − Qs)²
Friction loss kf × Qi²: set to 12% of the theoretical head at the design flow.
Shock loss ks × (Qi − Qs)²: calibrated to the empirical shut-off head ratio H0/H_BEP ≈ 1.05 + 0.005 × nq (limited to 1.08–1.45), with the slope of the curve at zero flow constrained to be non-positive so that no artificial hump is created.
Power and efficiency
P = [ ρ × g × Qi × Hth(Qi) + disc friction + mechanical loss ] × correction factor
Disc friction = 0.45×10⁻³ × ρ × u2³ × D2²
Mechanical loss = 1% × (theoretical power at design point + disc friction)
η = ρ × g × Q × H / P
If the maximum efficiency calculated with these formulas is higher than the statistical maximum efficiency of centrifugal pumps with the same flow and specific speed, the power is increased proportionally (i.e. the efficiency is reduced) to the statistical value; the statistical maximum efficiency is limited to 30%–92%.
NPSHr estimate
NPSH3 (the NPSH at a 3% head drop) is estimated from the inlet velocities:
c1m = Qi / A1
w1² = c1m² + u1²
NPSHr = (1.15 × c1m² + 0.25 × w1²) / (2g) × [1 + 1.2 × (max(0, 0.6 − Q/Qd))²]
The term in square brackets is the part-load recirculation allowance: NPSHr rises again when the flow is below 60% of the design flow Qd.
Curve range
The curve is calculated from zero flow to 1.4 times the design flow Qd, in 60 equal intervals (61 points). The part where the head falls below 5% of the shut-off head is cut off; if fewer than 6 points remain, “This parameter combination gives no valid curve” is reported. The BEP is found by searching for the point of highest efficiency between 0.2 and 1.4 times Qd.
Estimated performance curves
The chart in the middle, with flow on the horizontal axis. Hover to show a crosshair and the value of each curve; click a legend entry to hide or show that curve.
Head curve
Solid green line “Head”, on the left axis.
Efficiency curve
Solid blue line “Efficiency”, on the right % axis (0–100).
Shaft power curve
Dashed red line “Shaft power”, on the rightmost kW axis.
NPSHr curve
Dotted brown line “NPSHr”, sharing the left axis with the head (axis name “Head / NPSHr”). It is not calculated at zero flow.
BEP marker
The green dot on the head curve, labeled “BEP flow · head · efficiency”.
Units
The drop-down to the right of the chart title selects the display units: “L/s + m”, “m³/min + m”, “m³/h + m” or “USGPM + ft”; the default is m³/h + m, and your choice is remembered. The units affect only the display; power is always in kW.
Key indicators
The “Key indicators” panel on the right.
BEP flow
The BEP flow Q_BEP, shown in the selected unit.
BEP head
The BEP head H_BEP.
Best efficiency
The efficiency at the BEP, η_BEP, in %.
BEP shaft power
The shaft power at the BEP, in kW.
Max shaft power
The maximum shaft power over the whole estimated curve, in kW. Use this value as a reference when choosing a motor.
Shut-off head
The head at zero flow, H0.
BEP NPSHr
The estimated NPSHr at the BEP.
Specific speed nq
nq = n × √Q_BEP / H_BEP^0.75 (n in r/min, Q in m³/s, H in m)
The small “/ Ns” after it is the US specific speed:
Ns = n × √Q_BEP (USGPM) / H_BEP (ft)^0.75
The two are related by approximately Ns ≈ 51.6 × nq. Example (hypothetical numbers): n = 1480 r/min, Q = 0.05 m³/s, H = 30 m, nq ≈ 1480 × 0.224 / 12.8 ≈ 25.8, Ns ≈ 1333. For centrifugal pumps nq is generally between 10 and 120.
Suction specific speed
nss = n × √Q_BEP / NPSHr_BEP^0.75 (r/min, m³/s, m)
The higher the value, the better the suction performance; but if it is too high, recirculation and instability easily occur at part load.
Tip speed
u2, in m/s. The higher the tip speed, the more severe the wear in slurry pumps; a note is given above 40 m/s.
Head coefficient ψ
ψ = g × H_BEP / u2²
Example (hypothetical numbers): H = 30 m, u2 = 19.37 m/s, ψ = 294.3 / 375.2 ≈ 0.78.
Flow coefficient φ
φ = cm2 / u2 = Q_BEP / (A2 × u2)
cm2 is the outlet meridional velocity.
Slip factor
σ, indicating how far the actual outlet flow deviates from the blade direction with a finite number of blades; the closer to 1, the smaller the head loss. For the calculation, see Estimation method.
Hydraulic / volumetric efficiency
Hydraulic efficiency = actual head ÷ theoretical head at the design flow, in %.
Volumetric efficiency ηv, in %.
Design comparison
Pin as reference
Click “Pin as reference” to pin the current estimate; up to 4 designs can be pinned, and when you exceed this the oldest one is removed. Pinned designs are shown on the chart as dashed head curves (colored orange, purple, cyan and brown in turn, with legend entries “#1” to “#4”), and listed below the chart as “#n D2=… b2=… β2=…° n=… · BEP flow / head / efficiency%”. When you then change the parameters, you can compare the new result directly with the pinned designs.
Load
“Load” in a compared design's row fills all of that design's impeller parameters back into the left panel and recalculates the estimate.
Removing a compared design
The ✕ at the end of a compared design's row removes it. Compared designs are kept only on the current page and are cleared when you refresh.
Save as private model
Click “Save as private model” to open a dialog that saves the current estimated curve as a private model. Once saved, it can be used in Data Search, Filter Search and duty simulation like any other private model.
Pump model (save)
Default “Estimated design”; required, up to 64 characters. It appears in the model drop-downs of Filter Search and Data Search.
Pump size (save)
Default “D” followed by the impeller outlet diameter (e.g. D250); required, up to 64 characters.
Curve name (save)
Default “n” followed by the speed (e.g. n1480); up to 64 characters. It can be left empty, in which case the pump size is used as the curve name.
Speed range (save)
Two factors that are multiplied by the current speed to give the minimum and maximum speed of the private curve: minimum 0.3–1 (default 0.6), maximum 1–1.6 (default 1.2), step 0.05. For example, at 1480 r/min with 0.6–1.2, the curve covers about 888–1776 r/min. The maximum speed cannot exceed 5 times the minimum speed (e.g. 0.3–1.6 gives the message “Max/min speed ratio cannot exceed 5”), and the resulting speeds must also lie within 100–10000 r/min.
After saving
With the current speed as the rated speed, about 20 evenly spaced points are taken from the estimated curve to generate the curve in the same way as a “rated-speed performance table”; speed lines, iso-efficiency lines and iso-NPSHr lines are generated by the affinity laws.
The impeller outlet diameter and number of blades are recorded as well, and the data are marked as estimated; the curve page shows “Partly estimated” with the note “Curve estimated from impeller geometry; for preliminary selection only.”
On success the message “Saved as private model” appears and the curve opens in a new window.
On failure the specific reason is shown (e.g. “At most n private curves”, “At most 64 characters”); if the reason cannot be identified, “Save failed” is shown. The “Save” button is disabled while the pump model or pump size is empty.
Printing the estimate report
Click “Print” to generate an A4 report and open the print dialog (you can also save it as PDF). The report includes: the impeller geometry table, key indicators and warnings, the estimated performance curve chart, the estimated performance table, and the table of compared designs. The footer contains the accuracy note.
Estimated performance table
The “Estimated performance table” in the report has about 12 rows, taken at equal intervals from zero flow to the end of the curve, with the columns flow, head, efficiency %, shaft power kW and NPSHr, shown in the selected units.
Warning
When the estimate succeeds but the parameters are close to the limits of the method's validity, warnings are listed in orange below the key indicators; they do not affect the display of results.
Very low specific speed (nq < 10); the estimate may be less accurate
For impellers of very low specific speed (narrow passages, low flow and high head), losses make up a large share, and the one-dimensional method is less accurate.
High specific speed (nq > 120), approaching the mixed/axial-flow range; the estimate may be less accurate
The flow in high-specific-speed impellers is strongly three-dimensional, so this method becomes less applicable.
Large outlet blade angle (> 45°); the curve may show a hump
The shut-off head may be lower than the head at intermediate flows; the operating point may be unstable in parallel operation or under control.
Outlet width is large relative to outlet diameter
b2/D2 > 0.15.
Inlet diameter is large relative to outlet diameter
D1/D2 > 0.75.
Tip speed exceeds 40 m/s; check wear and strength
Tip speed u2 > 40 m/s. When pumping slurry, wear increases sharply with velocity, and the impeller strength must also be checked.
Flat curve; operating point may be unstable in parallel operation or under control
The shut-off head is less than 1.02 times the BEP head.
Error messages
When a parameter is outside its valid range or the combination is not reasonable, no curve is produced; instead, the reasons are listed with a red “✗” in place of the chart:
Impeller outlet diameter must be 50–3000 mm
The impeller outlet diameter D2 is outside 50–3000 mm.
Outlet width must be > 0 and ≤ 30% of outlet diameter
b2 is 0, or b2 > 0.3 × D2. Reduce b2 or increase D2.
Number of blades must be 2–12
The number of blades Z is outside 2–12.
Outlet blade angle must be 10°–90°
β2 is outside 10°–90°.
Inlet diameter must be > 0 and < 95% of outlet diameter
D1 is 0, or D1 ≥ 0.95 × D2. After changing the outlet diameter you often need to adjust the inlet diameter as well.
Hub diameter must be < 90% of inlet diameter
Hub diameter ≥ 0.9 × D1. Reduce the hub diameter or increase D1.
Inlet blade angle must be 8°–45°
β1 is outside 8°–45°.
Speed must be 100–10000 rpm
The speed is outside 100–10000 r/min.
Density must be 500–3000 kg/m³
The fluid density is outside 500–3000 kg/m³.
This parameter combination gives no valid curve; check the outlet angle and width
All parameters are within range, but the theoretical head at the design flow or the shut-off head is not positive, or there are too few valid curve points. This is usually because the outlet blade angle is too small and the outlet width too narrow while the inlet is too large, making the outlet radial velocity too high at the design flow. Increase β2 or b2, or reduce D1 or β1.
Accuracy notes
The estimates are for preliminary selection and comparison and typically deviate by 5%–15% from measured curves; for final selection, rely on test or manufacturer curves. The deviation comes mainly from the following: the slip factor, loss coefficients and efficiency levels are all statistical empirical values; the specific effects of the volute or diffuser, blade profile, surface roughness and clearances are not taken into account; and NPSHr is a simplified estimate based on inlet velocities. When comparing different designs, relative trends are more reliable than absolute values.