Filter Search 5: Configuration

This chapter describes step 5 of Filter Search, “Configuration”: determining the installation configuration — impeller, materials, frame, bearings, seal and so on — for the curve selected in step 4, while viewing the performance curve and the engineering check results live. You can enter this page only after selecting a curve in Filter Search 4: Curve selection.

Page layout

The top line shows “Pump type / curve name” of the selected curve.

The configuration form is arranged in pairs: Impeller / Impeller Material, Frame / Bearing Assembly, Liner / Liner Material, Seal Type / Shaft Material, followed by Sealing Gland Type, the expeller options, Centrifugal seal efficiency derating, Motor model / Motor Power, Drive Type / Motor RPM and HR/ER Method.

To the right of the form is the performance chart of the selected curve (below the form when the middle area is narrow), with the current duty point marked; it refreshes automatically about half a second after the configuration changes. Below the chart is the view toolbar.

The “Bearing Life” (“Critical Speed” for vertical/submersible pumps) and “Flange Load” tabs below this step, and the “Select Assist” panel on the right, update live with the configuration; see Select Assist (Engineering checks) and Bearing Life, Critical Speed and Flange Load.

Automatic configuration on entry

When you click “Next” in step 4, the page shows “Calculating configuration” and the system automatically produces a default configuration in the following order, switching to this page only when it is done:

1. Impeller: the impeller of that row in the search results; if it is not in the list, the first item.

2. Impeller material: the first item in the list.

3. Frame: selected automatically from the slurry shaft power (see Frame).

4. Bearing assembly: the first item under that frame; shaft material: the first item.

5. Liner: the first sub-category, with the default material of that sub-category as the liner material.

6. Casing material: the default material is taken automatically (no drop-down list).

7. Seal type: reset to “Gland” when the curve has changed.

8. Finally the checks, bearing life (or critical speed) and flange loads are calculated.

You can then change each item; every change recalculates the related results.

If some data fails to load because of the network or another reason, the top of the page shows “Configuration was not completed (some data failed to load). Please try again.” or the specific cause, together with a “Retry” button. Click “Retry” to recalculate the default configuration; re-entering this page from step 4 also recalculates.

Cascading options

Item changed · Items updated in cascade

Impeller · Impeller material reset to the first item; frame list reloaded and frame selected automatically by power; bearing assembly and shaft material reselected accordingly; vane diameter in HR/ER updated; bearing life (critical speed for vertical/submersible pumps) and checks recalculated

Impeller material, liner material, sealing gland type · Checks rerun

Frame · Bearing assembly reloaded with the first item selected; shaft material reset to the first item; bearing life (critical speed for vertical/submersible pumps) recalculated

Bearing assembly · Shaft material reloaded with the first item selected; bearing life (critical speed for vertical/submersible pumps) recalculated

Liner · Liner material reloaded with the default material selected; checks rerun

Seal type · Sealing gland type list reloaded and selection cleared; expeller and differential impeller cleared if not a centrifugal seal; checks rerun and bearing life recalculated

Shaft material, differential impeller · Checks rerun, bearing life (critical speed for vertical/submersible pumps) recalculated

Impeller and material

Impeller

Meaning: the impeller part numbers available for this curve.

Range: only impellers linked to the selected curve version are listed.

Default: the impeller of that row in the search results.

Effect on calculation and results:

The impeller diameter is used for the “Tip Speed” check and for the shaft stress and bearing life calculations.

The vane diameter is used for the pump-based HR/ER (Head Ratio / Efficiency Ratio) calculation.

It determines the available impeller materials and frames.

Common issue: the drop-down list can be cleared; after clearing, impeller material, frame, bearing assembly and shaft material all become empty, and the “Tip Speed” check shows “Please select a curve then configure impeller”.

Impeller Material

Meaning: the impeller material, shown as “material code - name”.

Range: only materials available for the selected impeller and having a tip speed limit are listed. Grayed out with the hint “Select impeller first” when no impeller is selected.

Default: the first item in the list.

Effect on calculation and results: determines the maximum allowable tip speed used by the “Tip Speed” check; different materials (e.g. wear-resistant alloy and rubber) have different limits.

Related check: when none is selected, “Tip Speed” shows “Missing impeller material code”.

Frame and bearings

Frame

Meaning: the frame (Frame, i.e. bearing housing/pedestal) model. The label shows the rated power of the selected frame, e.g. “Frame (Rating: 75 kW)”.

Unit: the rating is in kW.

Range: frames matching the selected curve version and impeller, sorted by rated power from small to large. Grayed out when no frame is available.

Default: selected automatically from the slurry shaft power — the smallest frame whose rated power is not less than the slurry shaft power; if no frame is large enough, the one with the largest rated power.

Automatic frame = among frames with rated power ≥ slurry shaft power, the one with the smallest rated power

Example: slurry shaft power 32.7 kW, available frames rated at 30, 55 and 110 kW: the 55 kW frame is selected automatically.

Effect on calculation and results: determines the available bearing assemblies; all rows of this frame are highlighted in light blue in the “Bearing Life” table.

Manual entry: for a frame model that is not in the frame library, select “Manual entry…” at the end of the drop-down list, then enter the frame model in the input box below (up to 60 characters). A manually entered frame:

is recorded only in the plan and the selection report (shown in the report as “Model (Manual)”);

does not take part in bearing life or shaft stress calculations, and the “Bearing Assembly” is grayed out;

the “Bearing Life” table below still lists the results of each frame in the library for comparison.

Selecting a frame from the library in the drop-down list again restores normal calculation.

Vertical and submersible pumps also get their frame selected automatically from the slurry shaft power, and the “Critical Speed” table is calculated from it; when you later change the impeller, frame, bearing assembly, shaft material or motor parameters, the critical speed table is recalculated automatically.

Bearing Assembly

Meaning: the bearing assembly (Bearing assembly) part number under the selected frame, comprising the dry end and wet end bearing models and the shaft.

Range: changes with the frame; grayed out when there is no data.

Default: the first item in the list.

Effect on calculation and results: determines the bearing dynamic load rating and shaft dimensions, directly affecting L10 life and shaft stress; determines the available shaft materials.

Shaft Material

Meaning: the material code of the shaft.

Range: the standard shaft materials of the selected bearing assembly, plus one fixed optional shaft material. Grayed out when there is no data.

Default: the first item in the list.

Effect on calculation and results: the yield strength and tensile strength of the material determine the allowable shaft stress, affecting the three columns “DE Stress / WE Stress / Thread Stress”; for vertical pumps it also affects the critical speed (elastic modulus, density).

Allowable stress = min(0.3 × yield strength, 0.18 × tensile strength)

Liner and casing

Liner

Meaning: the liner sub-category (e.g. metal liners, rubber-type liners), which determines the choices in “Liner Material” below.

Range: liner categories linked to the selected curve version.

Default: the first sub-category.

Liner Material

Meaning: the specific material of the pump liner, shown as “material code - description”.

Range: materials in this sub-category for which the selected pump has casing pressure data.

Default: the default material of the sub-category (if the first item in the list is a placeholder material and there are 3 or more items, the second item).

Effect on calculation and results: together with the casing material, determines the rated working pressure of the casing, affecting the “Casing Pressure” check and the “Casing Pressure” column of the “Bearing Life” table.

Casing Material

Meaning: the casing material. The web edition has no separate drop-down list; the system automatically takes the default material of the first casing material sub-category of the selected pump.

Effect on calculation and results: used to look up the rated working pressure of the casing. If the pump has no casing pressure data, the “Casing Pressure” check shows “More information required.” or “No pressure rating.”, and the “Casing Pressure” column of the bearing life table shows insufficient data.

Seal

Seal Type

Meaning: the shaft seal type.

Options:

Option · Description

Gland · Default. Requires gland seal water

Centrifugal · The expeller (Expeller) prevents leakage while running; an auxiliary seal works at standstill

Mechanical · Face seal between rotating and stationary rings

Range:

Vertical and submersible pumps: the drop-down list is grayed out and they are treated as having no shaft seal.

With multiple stages (more than 1 pump) there is no “Centrifugal” option; if a centrifugal seal was selected and you change to multi-stage, it reverts to a gland seal automatically.

It resets to a gland seal every time you select a different curve.

Effect on calculation and results: the seal causes an efficiency loss, which is included in the slurry shaft power, the automatic frame selection by power and the “Motor Power” check:

Centrifugal seal: efficiency reduced by the “Centrifugal seal efficiency derating” (default 3%), plus a further 9% when the differential impeller is ticked;

Mechanical seal: the derating factor depends on the pump discharge diameter and speed; the smaller the diameter and the lower the speed, the greater the derating;

Gland seal: no derating.

Derated efficiency = curve efficiency × (1 − derating factor)

Example: curve efficiency 65%, centrifugal seal derating 3%, so the efficiency used for the shaft power is 65% × 0.97 = 63.05%.

Related check: only a centrifugal seal gets the “Seal Pressure” check; for other seals this item shows “N/A”.

Centrifugal seal efficiency derating

Meaning: the efficiency reduction, in percent, equivalent to the power consumed by the centrifugal seal (expeller).

Display condition: shown when the seal type is “Centrifugal” (whether or not expeller data is available, and for private models too).

Unit: %.

Range: 0.5 to 30, in steps of 0.5.

Default: 3%. Practice differs between manufacturers; for example, if you usually calculate with 5%, simply change it to 5.

Effect on calculation and results: included in the slurry shaft power, the automatic frame selection by power, the “Motor Power” check and the shaft stress; when the differential impeller is ticked, a further 9% is deducted on top of this. The entered value is saved with the plan and written into the selection report.

Example: curve efficiency 65%, centrifugal seal derating changed to 5%, so the efficiency used for the shaft power is 65% × 0.95 = 61.75%, about 2.1% higher shaft power than with the default 3% (63.05%).

Sealing Gland Type

Meaning: the gland type of a gland seal.

Shown when: horizontal pump only, “Gland” selected and options available.

Default: none selected (cleared every time the seal type changes).

Effect on calculation and results: for the record only; not used in checks or life calculations.

Expeller Standard / Hi-Seal

Meaning: the type of expeller used by the centrifugal seal, one of two: “Std Expeller” or “Hi-Seal” (high seal pressure type).

Shown when: horizontal pump only, “Centrifugal” selected, and the selected pump and impeller have expeller data. If there is no expeller of a given type, that radio button is grayed out.

Default: Hi-Seal if a Hi-Seal expeller exists; otherwise the standard expeller.

Effect on calculation and results: determines the maximum inlet pressure the expeller can withstand, which is the criterion of the “Seal Pressure” check.

Related messages:

If the suction static head in step 2 is empty or 0 when the expeller is loaded, “Suction static head is required for the centrifugal seal inlet pressure check” is shown.

If the selected pump/impeller has no expeller data, the whole block is hidden and the “Seal Pressure” check shows “No expeller data available for this impeller.”.

The expeller is determined when you enter this page or switch the seal type; changing the impeller afterwards does not reselect the expeller. If necessary, switch the seal type once to refresh it.

Use differential impeller

The UI text is “Use differential impeller (calculated at 85% of impeller diameter)”.

Meaning: a differential impeller (impeller diameter taken as 85%) used together with the expeller to increase the centrifugal sealing capacity.

Shown when: on the same line as the expeller options; visible only with a centrifugal seal and expeller data.

Default: not ticked; cleared automatically when you change the curve or switch to a non-centrifugal seal.

Effect on calculation and results:

The duty speed in the seal pressure check, expeller curve, critical speed and bearing life calculations is multiplied by 1.18;

Shaft stress and bearing loads are calculated with 85% of the impeller diameter and 80% of the impeller mass;

Efficiency is reduced by a further 9% (see Seal Type);

The performance chart on the right is updated accordingly.

Expeller Curve

Click the “Expeller Curve” button to open the “Centrifugal Pressure Curve” dialog. The button is grayed out when no expeller is selected.

Dialog content:

Top information: expeller part number; when there is a duty speed, also Flow (Q) (flow per pump, L/s), Inlet Pressure (inlet pressure, kPa) and Maximum Allowable Pressure (maximum allowable pressure at the duty point, kPa).

The horizontal axis of the chart is flow Q (L/s); the vertical axis is “MAX. INLET GAUGE PRESSURE FOR NO SEAL LEAKAGE (kPa)”.

Each line corresponds to one speed, labeled with the speed (rpm) at its end; green lines are the speeds of the curve family, the blue line is the duty speed.

The red triangle is the duty point: its horizontal position is the flow per pump and its vertical position is the maximum allowable inlet pressure at that flow.

How to read it: if the inlet pressure is below the height of the red triangle, the expeller can run at this duty without leakage.

Inlet pressure (kPa) = Sm × 1000 × 9.81 × suction static head (m) / 1000

Example: Sm = 1.3, suction static head 5 m, inlet pressure = 1.3 × 9.81 × 5 ≈ 63.8 kPa. If the red triangle on the chart is at 120 kPa, the seal meets the requirement.

Common issue: “No data (requires generated speed curves and expeller dimensions)” means that the curve family or the expeller lacks the data needed for the calculation, so nothing can be drawn.

Motor and drive

These two rows share the same values as the motor parameters at the top of the “Bearing Life” tab (“Critical Speed” for vertical and submersible pumps); changing them in either place updates both.

Motor model

Meaning: the model of the motor to be fitted, e.g. “Y2-280M-4”.

Default: empty.

Effect on calculation and results: recorded only; it is saved with the plan and written into the “Motor” line of the selection report, and does not take part in calculations.

Select motor

“Select motor” next to “Motor model” (available after a pump is selected) opens a selection dialog. At the top it shows the pump shaft power (the slurry shaft power when available), the predicted pump speed and the drive type. When the pump has no shaft power data (for example, the curve has not been purchased yet), the dialog shows a “Pump shaft power (duty)” input box; the recommendation is based on the power entered there.

Standard motor: you can change the drive type, efficiency class, power margin factor, voltage and frequency. Motors for 2, 4, 6 and 8 poles are listed by the rules in Recommendation, with ★ on the recommended row. With direct coupling, if no pole count matches the pump speed, the message “No pole number matches the pump speed with direct coupling; use a belt drive, gearbox or VFD.” is shown.

My Motor Library: lists the motors in the library with their load factors (above 100% shown in red); requires Premium membership. In the enterprise selection portal this tab is called “Manufacturer motor library” and lists the motors entered by that enterprise (read-only; hidden when there are none).

Clicking “Use” fills in the motor model (for a standard motor in the form “IE3 55 kW 4P 250M”), motor power and motor speed; if you changed the drive type in the dialog, the drive type is filled in too. The motor power check and bearing life are recalculated at once.

Motor Power

Meaning: the rated power (kW) of the motor to be fitted. Used for the “Motor Power” check; see Motor Power.

Drive Type

Meaning: how the motor is connected to the pump.

Options:

Option · Calculation

Direct · Default. Driven directly through a coupling

Belt · Belt and pulley are selected automatically; belt tension and pulley weight are included in the bearing loads

Gearbox · Bearing loads are calculated as for a coupled direct drive

Motor with VFD · Bearing loads are calculated as for a coupled direct drive; the motor speed follows the pump speed, so only the rated speed needs to be entered

Effect on calculation and results: only “Belt” includes the belt tension and pulley loads; the other three are calculated as a coupled direct drive. The selected drive is written into the selection report. See Drive Type.

Motor RPM

Meaning: the rated speed of the motor (r/min), default 1450. It takes part in calculations only for a belt drive; see Motor RPM.

HR/ER and Slurry Shaft Power

HR/ER Method

Meaning: the method for correcting water performance for slurry; it is the same setting as “HR/ER Method” in step 3, and changes here take effect there too. After a curve is selected, pump-based methods (which need the vane diameter) appear in the list, and “WB Slurry Based” switches to “WB Standard” automatically. For the meaning of each method see Filter Search 3: More options.

Related action: when “User Defined...” is selected, the “Edit custom HR/ER...” link appears, which reopens the custom dialog.

HR and ER display

The current results are shown to the right of the drop-down list as “HR: x.xx ER: x.xx”. HR is the head ratio (slurry head / water head) and ER the efficiency ratio (slurry efficiency / water efficiency). Both are usually less than 1; the smaller the value, the more the slurry reduces head and efficiency; for water duties both are 1.

Slurry Shaft Power

Meaning: the shaft power of the pump under slurry conditions, shown after HR/ER, e.g. “· Slurry Shaft Power: 32.7 kW”. Shown once calculated (for horizontal, vertical and submersible pumps alike).

Unit: kW, one decimal place.

Slurry shaft power (kW) = Sm × Q (L/s) × H (m) × 0.981 / (η (%) × (1 − seal derating) × ER)

Here Q and H are the flow and slurry head per pump (the maximum duty point for range duties), and η is the water efficiency of the curve at the duty point; for froth slurries the result is further divided by the froth volume factor; when the liquid SG Sw is greater than 1, it is further multiplied by Sw.

Example: Sm = 1.3, Q = 50 L/s, H = 30 m, η = 65%, ER = 0.9, gland seal with no derating:

P = 1.3 × 50 × 30 × 0.981 / (65 × 0.9) ≈ 32.7 kW

Uses: automatic frame selection; multiplied by the safety factor, it is used for the “Motor Power” check and the shaft stress calculation.

Curve toolbar

The toolbar below the chart on the right contains, from left to right, the following.

View mode

Options: a single pump has only “Full Screen”; with more than 1 pump there are “Single Stage Curve” and “Multi Stage Curve”.

Effect on results: determines the curve opened by the “View” button: “Multi Stage Curve” shows the performance of the whole set with the stages combined (for single solid slurry and water); the other modes show the single-pump curve with the duty marked.

View

Opens the selected curve in a new window with the current duty point marked; when piping has been entered, the system curve is drawn as well. Viewing the full curve requires a purchase; see Curve Viewer and Curve purchases.

Duty Simulation (Configuration step)

The “Simulate” button opens Duty Simulation in a new tab, carrying over the current duty, slurry, piping and unit system; see Duty Simulation.

Change Pump Size

The two buttons “↑” and “↓” after “Change Pump Size:” switch between the different pump sizes that appeared in the results of step 4:

“↑” switches to the next size after the current one in the result list, “↓” to the previous size (the order follows the current sort order of the step 4 result table; when sorted by the “Pump” column, it is by discharge diameter from small to large).

After switching, the first curve of that size is selected automatically and the whole configuration is recalculated (“Calculating configuration” is shown).

When you are already at the first or last size, the corresponding button is grayed out.

The far right of the toolbar shows the current pump size and curve name.

Private models and public curves

When a private model or a public manufacturer curve is selected, the form on the left is replaced by the “Private model parameters” card:

The card lists the structural parameters entered by the user: impeller diameter mm, vane diameter mm, max tip speed m/s, impeller material, casing working pressure kPa, casing material, suction diameter mm, discharge diameter mm, min passage mm, number of vanes, impeller type, seal type, impeller part no / material, frames and liners (only the items that have been entered are shown).

“Edit” opens the edit page of that private model in a new tab; see Private models.

When no structural parameters have been entered, the message “No structural parameters entered: tip speed and casing pressure checks are N/A; pump-based HR/ER methods are unavailable.” is shown.

When no “Data for advanced filter calculations (optional)” has been entered, the note “Private curves have no impeller/material/frame/expeller data: centrifugal seal, critical speed, bearing life and flange load do not apply.” is shown; when it has been entered, the note “Bearing life, critical speed, centrifugal seal and flange loads are calculated from the advanced data entered for this private model; anything not entered does not apply.” is shown.

You can still choose the “Seal Type”: it affects the efficiency reduction and the “Motor Power” check; the derating of a mechanical seal is calculated from the entered discharge diameter, with no derating if none is entered.

When bearing assemblies have been entered, the card shows the “Frame” and “Bearing Assembly” dropdowns: the frame is selected automatically as the smallest frame whose rating covers the slurry shaft power (as for built-in curves), and the bearing assembly is the first one on that frame; the bearing life table (horizontal pumps) or critical speed table (vertical pumps) is calculated from these assemblies.

When expellers have been entered, after choosing centrifugal seal as the “Seal Type”, you can select “Std Expeller” or “Hi-Seal”, and open the “Expeller Curve”.

When flange loads have been entered, the “Flange Load” tab is shown.

For private models the impeller, impeller material, liner, liner material, shaft material and sealing gland type dropdowns are not shown (the impeller is the curve itself, and the shaft material follows the bearing assembly). If the corresponding advanced data has not been entered, the “Flange Load” tab is not shown and the bearing life table is empty.

Check · Handling for private curves

Tip Speed · Calculated only if the impeller diameter (or vane diameter) and max tip speed are entered; otherwise “N/A”

Casing Pressure · Calculated only if the casing pressure table (all rows are listed) or the casing working pressure is entered; otherwise “N/A”

Seal Pressure · Calculated only if expellers are entered, “Seal Type” is centrifugal seal and an expeller is selected; otherwise “N/A”

Crit. Speed · Calculated only for vertical pumps with a bearing assembly entered and a shaft depth selected in the critical speed table; otherwise “N/A”

Liner Speed, Frame Power · Private models only; shown when the liner max speed or the frame rating is entered, see Select Assist

All others · Same as catalog curves

FAQ

All drop-down lists are empty

The selected curve lacks linked impeller or frame data, or the curve has not been purchased. When it has not been purchased, “Select Assist” shows “Curve not purchased: checks and bearing / critical speed calculations require buying this curve”.

Step 6 greys out after changing the configuration

Step 6 requires that a speed and efficiency have been predicted for the selected curve; this has nothing to do with the configuration. If it is grayed out, go back to step 4 and confirm that the predicted speed and efficiency of the selected curve are not “-”.

Loading... If the page does not appear, please make sure JavaScript is enabled in your browser.