Viscosity Correction
Catalog curves and test curves are all measured with clean water. When a pump handles viscous liquids such as oils, syrups or polymer solutions, its flow, head and efficiency drop and its shaft power rises. Viscosity correction converts clean-water performance into viscous-liquid performance according to ANSI/HI 9.6.7 (the same method as ISO/TR 17766). It can also work backwards from a viscous duty to an equivalent clean-water duty for pump selection. The page is in the left workspace panel under “Viscosity Correction”.
Requirements and access
Viscosity Correction is a Premium feature, and members of an enterprise team can use it too. When a regular user opens it, the message ““Viscosity Correction” is a Premium feature” and a “Get Premium” button are shown. See Premium membership.
The page remembers the last conditions and performance points you entered and restores them the next time you open it.
How to open
Click “Viscosity Correction” in the left workspace panel.
On a curve page, click “File → Viscosity Correction”. This opens the page in a new window and uses the nominal-speed performance of that curve directly; the page shows “Curve: …”. The curve must be your own private model, a curve you have purchased, or a free curve. For a curve you have not purchased, the message “This curve has not been purchased, so its best efficiency point can't be read. Please enter it manually.” is shown. Click “Enter manually” to switch back to entering performance points by hand.
Calculation methods
Select one of the two calculation methods at the top of the page.
Water curve → viscous performance
Starting from the clean-water performance curve of a pump, find its performance curve when pumping a viscous liquid. Use it to check the flow, head and motor power that an existing pump can reach with the viscous liquid.
Viscous duty → equivalent water duty
Starting from the flow and head of a viscous duty, find the flow and head at which the pump should be selected on its clean-water performance curve. Use it for selection: first calculate the equivalent water duty, then select a pump for that duty in Data Search.
Inputs
Viscosity
The viscosity of the liquid at the pumping temperature. On the right, choose the unit: “cSt (mm²/s)” for kinematic viscosity, or “cP (mPa·s)” for dynamic viscosity. When you choose cP, it is converted to kinematic viscosity using the density below (cSt = cP ÷ relative density). Viscosity changes greatly with temperature, so enter the value at the actual pumping temperature.
Density
The liquid density in kg/m³. It is used to calculate the shaft power of the viscous liquid and to convert dynamic viscosity to kinematic viscosity.
Speed
The pump speed in r/min. When the page is opened from a curve, the nominal speed of the curve is used and this item is not shown.
Stages
The number of stages of a multistage pump. When calculating parameter B, the head per stage (total head ÷ number of stages) is used.
Double-suction impeller
When checked, parameter B is calculated with the flow per side (half of the total flow).
Water performance points (total head of the pump)
The clean-water performance points entered by hand for the “Water curve → viscous performance” method, one point per row: flow m³/h, head m and efficiency %. Enter at least 3 points, and at least 3 of them must have an efficiency value (used to determine the best efficiency point). Click “Paste from Excel” to paste several rows at once (flow, head and efficiency; efficiency can be omitted), click “Add row” to add a row, and click “✕” at the end of a row to delete it (keep at least 3 rows).
Viscous duty
For the “Viscous duty → equivalent water duty” method, enter the flow in m³/h and the head in m of the viscous duty.
Result
Any change to the inputs recalculates the result automatically.
Correction coefficients
The top of the result shows:
Item · Meaning
ν · Kinematic viscosity in cSt
B · Parameter B, a dimensionless number that combines the viscosity, the flow and single-stage head at the best efficiency point, and the speed. The larger B is, the greater the viscosity effect
C<sub>Q</sub> · Flow correction factor; viscous flow = water flow × C<sub>Q</sub>
C<sub>H,BEP</sub> · Head correction factor at the best efficiency point (equal to C<sub>Q</sub>)
C<sub>η</sub> · Efficiency correction factor; viscous efficiency = water efficiency × C<sub>η</sub>
The head correction factor C<sub>H</sub> varies with flow: it is 1 at shut-off, it approaches C<sub>H,BEP</sub> closer to the best efficiency point, and the correction is larger at high flow.
Performance curves and comparison table
Shown under the “Water curve → viscous performance” method:
Chart: the blue dashed lines are the water head, efficiency and shaft power; the orange solid lines are the viscous head, efficiency and shaft power.
Right side: the water best efficiency point, the viscous best efficiency point, and the shaft power at the best efficiency point (water → viscous).
Comparison table: for each water performance point, the water flow, head, efficiency and shaft power, the C<sub>H</sub> at that point, and the converted viscous flow, head, efficiency and shaft power. Water shaft power is calculated at a density of 1000 kg/m³; viscous shaft power is calculated at the density you entered.
Equivalent water duty
Shown under the “Viscous duty → equivalent water duty” method: the viscous duty and the calculated equivalent water duty (flow and head). Select the pump on the clean-water performance curve at the equivalent water duty. When pumping the viscous liquid, the efficiency is about the water efficiency × C<sub>η</sub>; size the motor on the viscous shaft power.
Messages
Message · Meaning
Parameter B is greater than 40 · Outside the applicable range of the method; the result is for reference only
Parameter B is not greater than 1 · The viscosity effect is negligible; performance is taken as water
NPSHr of the viscous liquid is not corrected by this method · Shown when the curve has NPSHr. When the viscosity is not high, the result is close to water; keep an adequate NPSH margin
Click “Print” to generate an A4 report: viscosity, density, speed, stages, parameter B and correction coefficients, the performance curve chart and the comparison table (or the equivalent water duty).
Notes
The method applies to Newtonian fluids with 1 < B < 40. Non-Newtonian fluids such as slurries and gas-containing liquids are not applicable. For slurry pumps handling slurries, use the head-ratio and efficiency-ratio derating in the filter search, see Filter 1: Flow Details.
The results are empirical estimates. For pumps with very high viscosity, or with very low or very high specific speed, verify with a test.