Test Bench Link and Condition Monitoring

Test bench acquisition software and site gateways / PLC host computers can push data directly to the platform. Test points from factory tests are automatically compiled into test records and accepted to ISO 9906. The flow, head, power, vibration, bearing temperature and other running data of a pump in the field are diagnosed against its performance curve, giving deviation from the curve, off-design operation, vibration limit exceedance and performance decay trends. The page is in the left work area under “Test bench & monitoring”.

Conditions of use

Test bench & monitoring is an enterprise team feature. All team members can view test records and monitoring diagnostics. Creating, disabling and resetting device keys, voiding test records and changing monitoring settings require being the team owner or having the “Test benches & monitoring devices” permission. See Member permissions.

Condition monitoring matches data to a pump by its serial number and its Pump Unit Records entry, so the pump must be registered there first. If the entry has a linked curve, head, efficiency, %BEP and NPSH margin can be diagnosed; without a linked curve, only vibration and bearing temperature are diagnosed.

Device keys

The “Device keys” tab manages the keys used by devices. A device key can only write data; it cannot read any data.

Types

Test bench: the test bench acquisition software pushes test points.

Monitoring: site gateways / PLC host computers push running data.

The two types of keys cannot be mixed.

Creating and resetting keys

Click “New device key”, choose the type, enter a name (for example, Bench 1 or Plant gateway), then click “Create”. The key is shown only once. The dialog also gives an example call; copy and save it. The list shows the last 4 characters of each key, the number of calls, the last used time and the source IP. If a key is leaked or a device is replaced, click “Reset key”; the old key stops working immediately. When a key is not needed, you can “Disable” it. When the team expires, all device keys are suspended.

Pushing test points from the bench

Bench software calls POST /api/device/bench/points with the request header Authorization: Bearer device key, and the request body is:

Field · Description

serial · Serial number, required

bench · Test bench number (optional)

model, operator · Model and test engineer (optional)

setup · Test conditions: specified speed, accuracy grade, flow and pressure units, power type, elevation difference between gauges, inner diameter of the pressure tapping section, guarantee points. Same inputs as in Pump Test Data; required in the first push

points · Test points: flow, inlet pressure, outlet pressure, measured speed, power (NPSH3 optional)

finish · true = this test is finished

Points are appended to the “Running” record with the same serial number and test bench, so you can push after each point and send finish=true with the last push. Each record holds up to 60 test points. Once there are 3 points, the response returns the current acceptance result and the maximum efficiency.

Test records

The “Test records” tab lists records by most recent update. You can search by serial number, model or test bench. It shows the number of points, maximum efficiency, acceptance result and status (Running / Finished). A record is linked automatically when its serial number matches that of a pump unit record.

Click a row to view the acceptance result, the maximum efficiency point, and the flow, head, shaft power and efficiency of each test point converted to the specified speed. The results are recalculated with the current algorithm every time they are opened.

“Open in test data processing”: passes the test conditions and test points to the “Pump Test Data” page, where you can view the fitted curves and tolerance cross and print the test report.

“Void”: for a test entered by mistake or entered twice. A voided record no longer appears in the list.

Pushing running data

The gateway calls POST /api/device/monitor with the same request header, and the request body is:

serial: serial number (the pump must already be registered in pump unit records).

readings: list of readings, up to 500 per request. Each reading may contain at (UTC time in ISO format; if omitted, the time of receipt), flow (m³/h), head (m), or p1 and p2 (inlet and outlet gauge pressure in kPa; the platform converts them to head), power (shaft power in kW), speed (r/min), vibration (RMS vibration velocity in mm/s), bearingTemp (°C), npsha (m), current (A, recorded only).

Push a request every 1–10 minutes. Each pump keeps up to 200,000 readings; when the limit is exceeded, the oldest readings are deleted.

Condition monitoring

The “Condition monitoring” tab lists pumps that have running data, showing status (Normal / Attention / Alarm), issues, the time of the latest data and the number of readings (counted over the last 7 days). Click a row to view its diagnosis; you can choose 7, 30, 90 or 365 days.

Diagnostic items

Diagnosis uses the median of the most recent readings within the selected period, to avoid false alarms from a single jump:

Item · Criteria

Vibration · ISO 10816-3: Group 1 (large, > 300 kW) on a rigid foundation 2.3 / 4.5 / 7.1 mm/s, on a flexible foundation 3.5 / 7.1 / 11; Group 2 (medium, 15–300 kW) rigid 1.4 / 2.8 / 4.5, flexible 2.3 / 4.5 / 7.1, marking the boundaries between zones A/B, B/C and C/D respectively. Zone C: Attention; zone D: Alarm

Bearing temperature · Default: 85 °C Attention, 95 °C Alarm

Head deviation · Difference between the measured head and the curve head at the same flow (converted by affinity laws to the measured speed). Below −5%: Attention; below −10%: Alarm. Common causes are wear of wear rings or impeller and increased clearances

Efficiency deviation · Difference between the measured efficiency (ρgQH / shaft power) and the curve efficiency. 5 percentage points below: Attention; 10 percentage points below: Alarm

Off-design · Flow as %BEP of the best efficiency point: 70%–120% is normal; below 50% or above 130%: Alarm

NPSH margin · NPSHa / NPSHr < 1.3: Attention; < 1.1: Alarm

Performance decay · Linear trend of the head deviation over time (only when there are at least 6 readings spanning more than 3 days and the trend is clear). Gives the change per 30 days and the approximate number of days until the head Attention limit is reached; if it will be reached within 30 days, the status is Attention

The two charts below show head deviation, efficiency deviation and %BEP over time, and vibration (with the B, C and D zone boundaries) and bearing temperature over time.

Monitoring settings

Each pump can be set separately: machine group and foundation type (which determine the vibration zone boundaries), custom vibration attention / alarm values (leave blank to use the standard), bearing temperature attention / alarm values, and attention values for head and efficiency drops (the alarm value is twice the attention value). When nothing is set, pumps with a motor power above 300 kW use Group 1, the others use Group 2, and the foundation is rigid.

Diagnostic results are intended to prompt inspection and schedule maintenance. They do not replace on-site testing or the judgment of the equipment manufacturer.