Filter Search 2: Head details

This chapter covers step 2 of Filter Search, “Head Details”: here you either enter the slurry head directly, or fill in the suction/discharge piping and let the program calculate the system head and the net positive suction head available NPSHa, while checking whether the velocity in each pipe section is below the settling velocity. In this step, the left half holds the head, NPSHa and system information, and the right half holds the suction pipe, discharge pipe, pipe velocity results and the installation diagram; on a narrow screen the two parts are stacked vertically.

Page overview

Area · Content

Left half · Slurry Head (Calculate / Define), NPSHa and Working Pressure display, Override NPSHa, Zl (Dredging), system information (Terminal Pressure, friction model, Altitude)

Right half · Suction Pipe, Discharge Pipe (multiple sections possible), fittings, pipe velocity and settling velocity display, critical velocity and Pipe ID range for non-Newtonian slurries, installation diagram

About 0.3 seconds after any input changes, everything is recalculated automatically; no button needs to be clicked.

Below the piping area, the hint reads “Fill in suction + discharge pipe parameters to activate pipe velocity checks”: only once the piping information is complete do the Suction Pipe Velocity and Discharge Pipe Velocity checks in the “Select Assist” panel give results.

When the piping information counts as “complete”:

Pump type · Inputs that must be greater than 0

Horizontal · The inner diameter and TEL of the suction pipe, and the inner diameter and TEL of discharge section 1

Vertical, Submersible · The inner diameter and TEL of discharge section 1 (the suction pipe is not used)

Slurry Head and NPSHa

Slurry Head

Meaning: the head the pump must deliver at the duty flow, expressed as a column of slurry (i.e. the system head, Slurry Head).

Unit: m; ft when the unit system is “USGPM, ft”.

Default: 0.

What to enter: entered manually when “Define” is selected; when “Calculate” is selected, the input box is grayed out and the value is calculated automatically from the piping.

Effect on calculations and results:

Divided by HR it gives the water head, which is used to search the clear-water performance curves and predict the speed (for multistage, it is then divided among the pumps; see Filter Search 3: More options).

Together with Sm it determines the working pressure; the model list on the “4 Curve Selection” page lists only models whose rated casing pressure is not below this working pressure.

With the “Use Range” duty mode, it is the “Nominal Head” in the Range Values box on the “1 Flow Details” page.

Related check: when the slurry head or water head is not greater than 0, the “Water (H), Slurry Head” check fails with the message “Check water and slurry head”. If you click “Search” in “Define” mode with a head not greater than 0, the message “Please enter or calculate the slurry head first” appears and the search is blocked.

Calculate mode

UI text: radio button “Calculate”.

Meaning: calculates the system head from the piping, static heads and terminal pressure entered on the right, and fills the result into the Slurry Head input box automatically (to 2 decimal places, in the current unit).

Prerequisite: the piping information is complete (see “Page overview”). If the piping is incomplete, no head is calculated, the input box keeps its previous value (initially 0) and all calculations continue to use that value; if it is 0, the head check fails.

Forced setting: when the slurry type is “Non-Newtonian”, the mode switches to “Calculate” automatically and the “Calculate / Define” radio buttons are grayed out, so you cannot change to Define.

Define mode

UI text: radio button “Define” (default).

Meaning: enter a known slurry head directly; the piping is then used only to calculate NPSHa and pipe velocities and does not affect the slurry head (if “Calculate min & max head from system curve” is still ticked, the min/max heads are still calculated from the piping).

Linked behavior: with “Use Range” and “Calculate min & max head from system curve” ticked, switching from “Calculate” to “Define” opens the “Min / Max Head” dialog; see “Min / Max Head dialog” in this chapter.

NPSHa and Working Pressure display

What is shown: a line below the slurry head, in the format “NPSHa: value unit Working Pressure: value kPa”.

When shown: when NPSHa can be calculated (horizontal pump with the suction pipe inner diameter entered, or the override ticked); the second part is shown only when the working pressure is greater than 0.

NPSHa: net positive suction head available, expressed as a column of slurry; for the calculation see “How NPSHa is calculated” in this chapter.

Working Pressure: the pressure at the pump discharge produced by the slurry head; see “Water head and Working Pressure”.

Override NPSHa

UI: check box “Override NPSHa”.

Default: unticked; NPSHa is calculated automatically from the suction pipe.

Purpose: tick it and enter NPSHa manually when you already have an NPSHa measured on site or specified by the design institute, or when the suction conditions cannot be described by a single suction pipe (for example, with a feed box, or several pumps sharing a suction manifold).

Effect on results: when ticked, the NPSHa check and “Filter using NPSHa” on the “4 Curve Selection” page use the entered value instead of the value calculated from the piping. An override value that is empty or 0 is treated as not entered, and the value calculated from the suction pipe is used.

NPSHa (override value)

When shown: appears after “Override NPSHa” is ticked.

Unit: m; ft when the unit system is “USGPM, ft”.

Default: at the moment you tick the box, the most recently calculated NPSHa is filled in; you can modify it from there.

What to enter: the net positive suction head available, expressed as a column of slurry.

Related check: for the rules of the NPSHa check see Select Assist (Engineering checks); vertical and submersible pumps are not checked for NPSHa.

Zl (Dredging)

Meaning: in dredging duties, the vertical height of the slurry column in the suction pipe, usually taken as the vertical depth from the suction mouth to the water surface. The slurry in the suction pipe is heavier than the water outside it, so the pump must overcome an additional differential column loss.

Unit: m; ft when the unit system is “USGPM, ft”.

Default: empty. The input box shows the hint “empty = not dredging”, and you can click the clear button to empty it. Empty or 0 is calculated as non-dredging.

When shown: only when the pump type is Horizontal, the pump system is Single Stage, and the slurry type is Single Solid or Water.

Effect on calculations and results: the differential column loss is calculated as follows and deducted from both the static head term and NPSHa:

Differential column loss = Zl × (Sm − Sw) / Sm

In addition, once Zl is entered, “Pump Application” is set to “Dredging” automatically and the installation diagram shows the dredging diagram.

Example (hypothetical data): Zl = 15 m, Sm = 1.3, Sw = 1.0, differential column loss = 15 × 0.3 / 1.3 ≈ 3.46 m.

Note: If you later change to a multistage pump or another slurry type, the Zl input box is hidden, but the value already entered is still used in the calculations. When the duty is no longer a dredging duty, clear Zl first before changing other conditions.

System Info

Terminal Pressure

Meaning: the gauge pressure that must be maintained at the end of the discharge pipe, for example the cyclone inlet pressure or the filter press feed pressure. Enter 0 when discharging into an open tank.

Unit: kPa (does not change with the unit system).

Default: 0.

Effect on calculations and results: converted to a column of slurry and added to the system head:

Terminal pressure term (m) = P (kPa) ÷ (9.81 × Sm)      (Sm less than 1 is taken as 1)

When the terminal pressure is greater than 0, the installation diagram shows a diagram with a cyclone.

Example (hypothetical data): P = 50 kPa, Sm = 1.23, terminal pressure term = 50 ÷ (9.81 × 1.23) ≈ 4.14 m.

Friction Model

Options: “Darcy” (default), “Hazen-Williams”.

Meaning: the formula used to calculate the straight-pipe friction loss; see “Friction loss (Darcy)” and “Friction loss (Hazen-Williams)” in this chapter.

Linked behavior: the factor input of every pipe section switches accordingly: Darcy shows “K Factor”, Hazen-Williams shows “C Factor”. The two sets of factors are stored separately, so switching back and forth loses nothing.

Which to choose: Darcy is recommended for slurry transport and for ordinary steel pipes and rubber-lined pipes; choose Hazen-Williams only when the data you have gives a Hazen-Williams C value (common for clean-water supply and drainage pipes).

Altitude

Meaning: the altitude of the pump station site.

Unit: m (does not change with the unit system).

Default: 0; when it is 0 or empty, “At sea level” is shown on the right.

Effect on calculations and results: the higher the altitude, the lower the atmospheric pressure and the smaller the NPSHa; see “Atmospheric head and vapor pressure head”. It affects only NPSHa, not the system head.

Suction Pipe

The suction pipe is used only for horizontal pumps. For vertical and submersible pumps this block is still shown, but its inputs are not used in the calculations.

Inner Diameter ID (Suction Pipe)

Meaning: the inner diameter of the suction pipe.

Unit: mm (does not change with the unit system).

Default: empty.

Effect on calculations and results: determines the suction pipe velocity v = 1273 × Q ÷ ID² (Q in L/s, ID in mm, v in m/s), which in turn affects the suction friction, entrance loss, NPSHa and the suction pipe velocity check. If only the suction pipe inner diameter is entered (without TEL), NPSHa is still calculated, with the suction friction taken as 0.

Related check: when the suction pipe velocity is below the settling velocity for that pipe diameter, the velocity row below turns red and the “Suction Pipe Velocity” check fails.

TEL (Suction Pipe)

Meaning: the Total Equivalent Length of the suction pipe, used to calculate the straight-pipe friction.

Unit: m (does not change with the unit system; it is entered in m even with “USGPM, ft”).

What to enter: the straight pipe length. If bends and valves are already entered item by item with their K under “Fittings”, do not convert them into equivalent length here as well, to avoid counting them twice; conversely, if they are already included in TEL, do not add fittings.

Common mistake: leaving it empty or entering 0 when the suction pipe is very short; the piping information is then incomplete, and neither the system head nor the pipe velocity checks are calculated. Enter an actual length greater than 0.

Static Head Hs (Suction Pipe)

Meaning: the height of the suction liquid level relative to the pump centerline. Enter a positive value when the level is above the pump center (flooded suction) and a negative value when it is below the pump center (suction lift).

Unit: m; ft when the unit system is “USGPM, ft”.

Default: empty (taken as 0).

Effect on calculations and results:

Static head term = Hd − Hs (minus the dredging differential loss).

Added directly to NPSHa: the larger Hs, the larger NPSHa.

Installation diagram: a positive value shows the flooded suction diagram, a negative value the suction lift diagram.

When a centrifugal seal is selected on the “5 Configuration” page, it is used for the expeller inlet pressure check; if it is empty, the message “Suction static head is required for the centrifugal seal inlet pressure check” appears.

Pipe material (Suction Pipe)

Meaning: choose the suction pipe material from the pipe material library; once selected, the K factor and C factor of that material are filled in automatically.

Options: the first item “- User Defined -” (K = 0.05, C = 100), followed by the materials in the pipe material library.

Default: none selected; the factors are K = 0.05, C = 100.

Note: you can still modify the factors manually after choosing a material.

K Factor / C Factor (Suction Pipe)

Meaning:

With the Darcy model, “K Factor” is shown: the absolute roughness ε of the pipe wall, in mm.

With the Hazen-Williams model, “C Factor” is shown: the Hazen-Williams roughness coefficient, dimensionless; the larger the value, the smoother the pipe wall.

Default: K = 0.05, C = 100.

What to enter: preferably choose a pipe material to fill it in automatically; for special lined pipes, consult the pipe manufacturer's data. For old pipes with wear or scaling, increase K or reduce C as appropriate.

Fittings (Suction Pipe)

Click the “+” to the right of “Fittings” to add a row; multiple rows can be added. For the meaning of each field in a row, see “Fitting types and fitting rows” in this chapter.

Suction fitting losses are calculated with the suction pipe velocity and are included in both the system head and NPSHa.

Discharge Pipe

The discharge pipe consists of one or more sections in series, suitable for lines that change diameter or material along the way. Pipe velocity, friction, fitting losses and settling velocity are calculated separately for each section.

Static Head Hd (Discharge Pipe)

Meaning: the height of the discharge point relative to the pump centerline (for vertical and submersible pumps, the height of the discharge point relative to the suction liquid level). Only one value is entered for the whole discharge pipe, shared by all sections.

Unit: m; ft when the unit system is “USGPM, ft”.

Default: empty (taken as 0).

Effect on calculations and results: for horizontal pumps the static head term = Hd − Hs − dredging differential loss; for vertical and submersible pumps the static head term = Hd.

Add Section

UI: the “+Add Section” button to the right of the “Discharge Pipe” title.

Function: adds a new section at the end (Section 2, Section 3 …); a new section defaults to K = 0.05, C = 100 and no fittings.

Common mistake: not entering the inner diameter of the new section. Empty sections with neither inner diameter nor length are ignored in the calculation; a section with only one of the two cannot be calculated, and in “Calculate” mode the whole system head cannot be calculated either (the slurry head is not updated). Fill in every section completely, and delete sections you do not need.

Deleting a section

UI: the “✕” to the right of each section title; it appears only when there are 2 or more sections.

Action: after clicking, confirm “Remove pipe section?” and choose “Yes” to delete. The discharge pipe must keep at least 1 section.

Inner Diameter ID (discharge section)

Meaning: the inner diameter of this section.

Unit: mm.

Effect on calculations and results: determines the pipe velocity, friction, fitting losses and settling velocity of this section. The inner diameter of discharge section 1 also counts towards “piping information complete”.

Non-Newtonian slurries: after you change the flow, concentration or yield stress, the inner diameter of section 1 is set automatically to the critical pipe diameter at the current flow; when the inner diameter is outside the recommended range, a red note is shown.

TEL (discharge section)

Meaning: the straight-pipe equivalent length of this section.

Unit: m (does not change with the unit system).

Note: the sum of the TEL of all sections is the total length of the discharge pipe. The same principle as for the suction pipe applies: avoid counting fittings twice.

Pipe material (discharge section)

Used in the same way as “Pipe material (Suction Pipe)”; each section can have a different material.

K Factor / C Factor (discharge section)

The meaning and defaults are the same as for “K Factor / C Factor (Suction Pipe)”; each section is set separately.

Override settling velocity

UI: check box “Override settling velocity” + input box on the right (m/s), symbol Vs. Only discharge sections have this; the suction pipe does not.

When shown: not shown when the slurry type is “Non-Newtonian” (non-Newtonian slurries use the critical velocity instead).

Default: unticked; the input box can be edited only after ticking.

Purpose: when you have field tests, loop tests or more reliable empirical values, use it to replace the settling velocity calculated by the program's formula.

Effect on results: when ticked and a value is entered, the velocity row of this section and the “Discharge Pipe Velocity” check use the entered value instead.

Fittings (discharge section)

Each section has its own “Fittings” list; click “+” to add. Fitting losses are calculated with the pipe velocity of the section they are in.

Fitting types and fitting rows

Each fitting row contains: a type drop-down, name, quantity, factor and a delete button.

Fitting type

Options: Long Radius Bend 90, Long Radius Bend 135, Short Radius Bend 90, Short Radius Bend 135, Elbow, Tee, Rubber Hose, Diaphragm Valve, Full Bore Valve, Plug-Lub Valve, Tech Taylor Valve, User defined....

Default: a new row is “Long Radius Bend 90”.

Note: the type is only a label; choosing a type does not fill in a resistance coefficient automatically, so you must enter the factor yourself.

Name (fitting)

Meaning: the name of a user-defined fitting.

When available: editable only when the type is “User defined...”; grayed out for other types.

Quantity (fitting)

Meaning: the number of identical fittings.

Default: 1; empty or 0 is taken as 1.

Factor (fitting)

Meaning: the local resistance coefficient K of a single fitting (dimensionless).

Note: whichever friction model is selected, fitting losses are always calculated as K × v²/2g. With the Hazen-Williams model the placeholder of the input box shows “C”, but what you enter is still the local resistance coefficient K.

What to enter: consult the fitting or valve manufacturer's data, or a general hydraulics handbook.

Common mistake: adding a fitting without entering its factor; the loss of that fitting is then taken as 0.

Deleting a fitting

UI: the “✕” at the end of the row.

Action: confirm “Remove fitting from pipe section?” and choose “Yes” to delete.

Pipe velocity and Settling Velocity display

Once the piping information is complete, the velocity results for each pipe are shown below the discharge pipe; rows where the pipe velocity is below the settling velocity (or critical velocity) are shown in red, indicating a risk of particle deposition and pipe blockage at that point.

Suction Pipe velocity row

Format: “Suction Pipe: velocity m/s · Settling Velocity value m/s”.

When shown: horizontal pump with the suction pipe inner diameter entered.

The settling velocity is calculated for the suction pipe inner diameter; for non-Newtonian slurries it is shown as “Critical Velocity”.

Discharge section velocity rows

Format: “Section n: Inner Diameter value mm · velocity m/s · Settling Velocity value m/s · K value” (with Hazen-Williams, the last item shows the C value).

One row per discharge section; sections with “Override settling velocity” ticked show the override value.

What to do about red rows: reduce the inner diameter of that section to increase the pipe velocity, or verify that d50, S and Cv are entered correctly.

Critical Velocity and Pipe ID range (Non-Newtonian)

Shown when the slurry type is “Non-Newtonian”:

Critical Velocity: the velocity at which the slurry changes from laminar to turbulent flow, calculated from the yield stress and Sm (m/s). The pipe velocity should not be below the critical velocity.

Pipe ID range: in the format “minimum mm < ID < maximum mm”; these are the pipe inner diameters at which the critical velocity is just reached at 0.9 times and 1.1 times the duty flow:

D = √(1273 × Q ÷ Vc)      (D in mm, Q in L/s, Vc = critical velocity in m/s)

Out-of-range note: when the inner diameter of the suction pipe or of a discharge section is outside the recommended range, a red note is shown, for example “Section 1 ID 200 mm out of range”.

Installation diagram

Once the piping information is complete, an installation diagram matching the current inputs is shown at the lower right of the page:

Condition · Diagram

Horizontal, Zl entered · Dredging

Horizontal, Hs > 0 · Flooded suction (with cyclone when terminal pressure > 0)

Horizontal, Hs < 0 · Suction lift (with cyclone when terminal pressure > 0)

Vertical · Vertical pump (with cyclone when terminal pressure > 0)

No diagram is shown for horizontal pumps with Hs equal to 0 or empty, or for submersible pumps.

Min / Max Head dialog

When it appears

The dialog, titled “Min / Max Head”, opens when all of the following conditions are met:

1. “Use Range” is selected on the “1 Flow Details” page;

2. “Calculate min & max head from system curve” is ticked;

3. On this page the slurry head is switched from “Calculate” to “Define”.

The head is then no longer calculated from the piping, and you need to give the heads at the two ends of the range manually.

Min Head (dialog)

Unit: follows the unit system, m or ft.

Default: the current min head.

Max Head (dialog)

Unit: follows the unit system, m or ft.

Default: the current max head.

OK and Cancel (Min / Max Head)

OK: writes the two values into the Range Values box on the “1 Flow Details” page and unticks “Calculate min & max head from system curve”; you can then continue to modify them in the Range Values box.

Cancel (or closing the dialog): unticks that check box and resets the duty mode to “Single Duty”.

How system head is calculated

In “Calculate” mode, the program determines the slurry head as follows. All head terms are in meters of slurry column; straight-pipe friction is calculated with the viscosity of water, which amounts to assuming that the slurry friction is close to that of water when the pipe velocity is above the settling velocity.

Formula components

Horizontal pumps:

H = (Hd − Hs − Zl×(Sm − Sw)/Sm)          static head term
  + P ÷ (9.81 × Sm)                       terminal pressure term
  + Σ h_f,disch + Σ h_k,disch             friction + fitting losses of discharge sections
  + h_f,suct + h_k,suct                   suction pipe friction + fitting losses
  + max(Σ v_d²/2g − v_s²/2g, 0)           velocity head term
  + 0.5 × v_s²/2g                         suction entrance loss

Vertical and submersible pumps:

H = Hd + P ÷ (9.81 × Sm) + Σ h_f,disch + Σ h_k,disch + Σ v_d²/2g

where v_s is the suction pipe velocity, v_d the pipe velocity of each discharge section, and g = 9.81 m/s².

Static head term

Horizontal: Hd − Hs; for dredging, the differential column loss Zl × (Sm − Sw) / Sm is also subtracted.

Vertical and submersible: Hd only.

Terminal pressure term

P ÷ (9.81 × Sm), where P is the terminal pressure in kPa; Sm less than 1 is taken as 1.

Pipe velocity

v (m/s) = 1273 × Q (L/s) ÷ ID² (mm²)

Friction loss (Darcy)

h_f = f × (TEL / D) × v²/2g
f   = 0.25 / [lg( ε/(3.7·D) + 5.74/Re^0.9 )]²      (Swamee-Jain explicit formula)
Re  = v × D / ν,   ν = 1.0×10⁻⁶ m²/s

ε is the “K Factor” (mm) and D is the pipe inner diameter; when calculating ε/(3.7·D), ε and D are in the same length unit.

Friction loss (Hazen-Williams)

The classic Hazen-Williams formula is used; its general form in SI units is:

h_f = 10.67 × TEL × Q^1.85 ÷ (C^1.85 × D^4.87)      (Q in m³/s, D in m)

C is the “C Factor”. Internally the program uses an equivalent form of the coefficients adapted to L/s and mm.

Fitting losses

h_k = Σ (quantity × K × v²/2g)

v is the pipe velocity of the section in which the fitting is located.

Velocity head and entrance loss

Velocity head term: for horizontal pumps, the sum of the velocity heads of the discharge sections minus the suction pipe velocity head (taken as 0 if negative); for vertical and submersible pumps, the sum of the velocity heads of the discharge sections.

Entrance loss: for horizontal pumps, 0.5 times the suction pipe velocity head is added.

System head example

Hypothetical data: horizontal pump, Q = 50 L/s, Sm = 1.23, terminal pressure 0, Darcy friction model, K = 0.05 mm.

Suction pipe: ID = 200 mm, TEL = 10 m, Hs = +2 m, no fittings.

Discharge pipe: 1 section, ID = 150 mm, TEL = 200 m, Hd = 20 m, 4 bends, assumed K = 0.3 each.

Suction velocity     v_s = 1273 × 50 ÷ 200² ≈ 1.59 m/s,  v_s²/2g ≈ 0.129 m
Discharge velocity   v_d = 1273 × 50 ÷ 150² ≈ 2.83 m/s,  v_d²/2g ≈ 0.408 m
Suction friction     Re ≈ 3.2×10⁵, f ≈ 0.0166, h_f ≈ 0.0166 × (10/0.2) × 0.129 ≈ 0.11 m
Discharge friction   Re ≈ 4.2×10⁵, f ≈ 0.0168, h_f ≈ 0.0168 × (200/0.15) × 0.408 ≈ 9.15 m
Fitting losses       4 × 0.3 × 0.408 ≈ 0.49 m
Velocity head term   0.408 − 0.129 ≈ 0.28 m
Entrance loss        0.5 × 0.129 ≈ 0.06 m
Static head term     20 − 2 = 18 m
H ≈ 18 + 0 + 9.15 + 0.49 + 0.11 + 0.28 + 0.06 ≈ 28.1 m (slurry column)

Water head and Working Pressure

Water head = Slurry Head ÷ HR
Working Pressure (kPa) = Sm × 9.81 × Slurry Head (m)

Continuing the example above, if HR = 0.90, the water head ≈ 28.1 ÷ 0.90 ≈ 31.2 m; the working pressure ≈ 1.23 × 9.81 × 28.1 ≈ 339 kPa.

How NPSHa is calculated

NPSHa is calculated only for horizontal pumps, using the flow per pump. When “Override NPSHa” is ticked, the entered value is used directly.

NPSHa formula components

NPSHa = (Ha − Hv) ÷ Sm  +  Hs  −  Zl×(Sm − Sw)/Sm  −  (0.5×v_s²/2g + h_f,suct + h_k,suct)

Term · Meaning

Ha · Water column height corresponding to the local atmospheric pressure; varies with altitude

Hv · Water column height corresponding to the saturated vapor pressure of the liquid at the slurry temperature; varies with temperature

÷ Sm · Converts the water column into a slurry column

Hs · Suction static head: positive for flooded suction, negative for suction lift

Zl×(Sm − Sw)/Sm · Dredging differential column loss; 0 when Zl is not entered

0.5×v_s²/2g · Suction entrance loss

h_f,suct, h_k,suct · Straight-pipe friction and fitting losses of the suction pipe

Atmospheric head and vapor pressure head

Atmospheric head Ha: calculated from the approximate relationship of the standard atmosphere with altitude. About 10.34 m at sea level, about 9.16 m at 1000 m altitude.

Vapor pressure head Hv: converted from the saturated vapor pressure at the temperature. About 0.23 m at 20 °C, about 2.0 m at 60 °C. The temperature is the temperature T on the “1 Flow Details” page.

NPSHa example

Using the system head example above (sea level, 20 °C, Sm = 1.23, Hs = +2 m):

(Ha − Hv) ÷ Sm ≈ (10.34 − 0.23) ÷ 1.23 ≈ 8.22 m
Suction losses ≈ 0.06 + 0.11 = 0.17 m
NPSHa          ≈ 8.22 + 2 − 0.17 ≈ 10.05 m

With a suction lift of Hs = −3 m instead, NPSHa ≈ 8.22 − 3 − 0.17 ≈ 5.05 m.

How NPSHa is used

The NPSHa check in “Select Assist”: it fails when NPSHa is too small (less than 1 m), lies in a range prone to cavitation, or is below the net positive suction head required NPSHr of the selected curve at the duty point; see Select Assist (Engineering checks) for details.

When “Filter using NPSHa” is ticked on the “4 Curve Selection” page (horizontal pumps only), NPSHa is used to exclude curves whose NPSHr does not meet it; see Filter Search 4: Curve selection.

NPSHa is not calculated for vertical and submersible pumps; the NPSHa check shows “NPSHa Ignored.”.

When the suction pipe inner diameter is not entered and no override is given, NPSHa cannot be calculated, and the check shows “NPSHa will be ignored.”.

Notes on units

Input / display · Unit · Changes with unit system?

Slurry Head, NPSHa, Zl, Static Head Hs / Hd, Min / Max Head · m or ft · Yes

Inner Diameter ID · mm · No

TEL · m · No

Terminal Pressure, Working Pressure · kPa · No

Altitude · m · No

Pipe velocity, settling velocity, critical velocity · m/s · No

Pipe ID range · mm · No

Tip: When you switch the unit system, heads, static heads and other values already entered are converted automatically; see Filter Search 1: Fluid details for details.

Common mistakes

Selecting “Calculate” but leaving the TEL of the suction pipe or discharge section 1 empty: the piping is incomplete and the slurry head is not updated (if it is initially 0, the head check fails; if a head was entered earlier, the old value continues to be used).

Getting the sign of Hs wrong: when the liquid level is below the pump center (suction lift), enter a negative value.

Converting bends and valves into equivalent length and also adding them again under “Fittings”, which overestimates the friction.

Adding fittings without entering their factors, so the fitting losses are taken as 0.

Entering the equivalent length in ft (with the unit system “USGPM, ft”), whereas the equivalent length is always calculated in m.

Entering data in the suction pipe for vertical or submersible pumps and expecting it to be included in the head; for these two pump types only the discharge pipe is calculated.

Forgetting to clear Zl after a dredging duty, so that Zl is still used in the calculations after other conditions are changed.