Pump Test Data
Pump Test Data is for factory acceptance tests and type tests of pumps. Enter the flow, inlet and outlet pressure, speed and power at each test point; convert them to the specified speed by the methods of ISO 9906 / GB/T 3216 Rotodynamic pumps — Hydraulic performance acceptance tests; fit the head, efficiency and power curves; check whether the guarantee point is met; print the test report; and save the result as a private model. The page is in the left workspace panel under “Pump Test Data”.
Requirements
Pump Test Data is a Premium feature, and members of an enterprise team can use it too. When a regular user opens it, the message “Pump Test Data” is a Premium feature and a “Get Premium” button are shown. See Premium membership.
The page remembers the test conditions and readings you last entered, and restores them the next time you open it.
Test conditions
Test information
Customer, pump model, serial number, test date and tester appear only in the header of the test report. The pump model and serial number are also used as the default model name and size name for “Save as private model”.
Acceptance grade
The six ISO 9906 grades are 1B, 1E, 1U, 2B, 2U and 3B; the default is 2B. The grade sets the tolerances of flow, head and efficiency (or power) at the guarantee point:
Grade · Flow · Head · Efficiency · Power
1B · ±5% · ±3% · −3% · +4%
1E · ±5% · ±3% · 0 · +4%
1U · 0 to +10% · 0 to +6% · 0 · +10%
2B · ±8% · ±5% · −5% · +8%
2U · 0 to +16% · 0 to +10% · −5% · +16%
3B · ±9% · ±7% · −7% · +9%
Specified speed
The speed (r/min) at the guarantee point. All test points are converted to this speed by the affinity laws before fitting and judgement.
Units
“Flow unit”: m³/h, L/s, m³/min.
“Pressure unit”: kPa, MPa, bar, mH₂O.
Power reading
“Shaft power”: shaft power measured directly (torque meter).
“Motor input power”: motor input power measured by a power meter. Also enter “Motor efficiency”; shaft power = input power × motor efficiency.
Fluid density
kg/m³; clean water is about 1000. Used to calculate head and efficiency from pressure.
Gauge heights and pipe bores
“Inlet gauge height” and “Outlet gauge height”: the height (m) of the centre of the inlet and outlet pressure gauges above a common datum. The difference is included in the head.
“Inlet pipe bore” and “Outlet pipe bore”: the internal diameter (mm) of the pipe at the pressure tapping sections, used to calculate the difference of velocity heads. Enter 0 to leave out velocity heads.
Guarantee point
Guaranteed flow Q (m³/h) and head H (m), with an optional guaranteed efficiency η (%) or guaranteed power P (kW). Only one of the two can be entered: if efficiency is entered, power cannot be. If no guarantee point is entered, the data are processed but no acceptance judgement is made.
“Use ±10% / ±8% for shaft power ≤ 10 kW”: checked by default. ISO 9906 specifies that, where the parties have not agreed otherwise, the flow and head tolerances of small pumps are widened to ±10% and ±8%. This applies only to 2B, 2U and 3B.
Test readings
One test point per row: flow, inlet pressure (gauge), outlet pressure (gauge), measured speed and power.
If the inlet is under vacuum, enter the inlet pressure as a negative value.
Leave measured speed blank if it equals the specified speed.
At least 3 test points at different flows, up to 60. Click “Add row” to add a row; “✕” at the end of a row deletes it; “Clear” restores 7 empty rows.
“Paste from Excel”: in Excel, select the 5 columns (flow, inlet pressure, outlet pressure, measured speed, power), copy them, paste them into the dialog and click “Import”. If only 4 columns are pasted, the speed column is treated as absent.
Once 3 or more test points are entered, the results are calculated automatically. Changing any input recalculates them.
Calculation method
Head and efficiency
Pump head = (outlet pressure − inlet pressure) ÷ (ρg) + (outlet gauge height − inlet gauge height) + (outlet velocity² − inlet velocity²) ÷ 2g.
Pump efficiency = ρgQH ÷ shaft power.
If the efficiency calculated at a point exceeds 100%, the message “Row … gives an efficiency above 100%; check pressures, power or units” is shown.
Conversion to specified speed
By the affinity laws: flow × (n_specified / n_measured), head × (n_specified / n_measured)², power × (n_specified / n_measured)³, and efficiency unchanged. The ratio of measured speed to specified speed must be between 0.5 and 2. A deviation of more than 20% shows a message that the conversion error will be larger.
Curve fitting
Head and power are fitted with cubic polynomials, and efficiency with a quartic polynomial (of lower order when there are few points), by least squares. The best efficiency point is the peak of the fitted efficiency curve.
Acceptance check
Flow / head
By the ISO 9906 tolerance cross: centred on the guarantee point, draw a horizontal segment whose length is the flow tolerance and a vertical segment whose length is the head tolerance. If the fitted head curve intersects either segment, the point passes. The results show:
“Head deviation at guaranteed flow”: the deviation of the curve's head at the guaranteed flow from the guaranteed head.
“Flow deviation at guaranteed head”: the deviation of the curve's flow at the guaranteed head from the guaranteed flow.
If either of the two is within tolerance, “Flow / head” shows ✓.
Efficiency or power
Draw a straight line from the origin to the guarantee point, and take the efficiency (or power) at its intersection with the head curve:
Efficiency ≥ guaranteed efficiency × (1 + efficiency tolerance) is a pass.
Power ≤ guaranteed power × (1 + power tolerance) is a pass.
If both flow / head and efficiency (or power) pass, the top of the page shows “Grade … acceptance: PASS”; otherwise it shows “Grade … acceptance: FAIL”. When tolerances have been relaxed for a small pump, “small-pump tolerances” is noted after it.
Results
Chart: the fitted head (blue), efficiency (green) and shaft power (orange, dashed) curves and the converted test points. With a guarantee point, the guarantee point and the tolerance cross are drawn in red.
Right side: best efficiency point, shut-off head, maximum shaft power, head fit deviation, and the tolerances, the two deviations and the judgement.
“Points converted to … r/min” table: for each test point, the converted flow, head, power, efficiency and speed ratio.
Messages
Message · Meaning
Points deviate more than 3% from the fitted curve · The readings may be wrong, or the points scatter widely
The best efficiency point is at the edge of the measured range · The points may not cover the high-efficiency zone; measure larger or smaller flows
The guarantee point is outside the measured range, so it cannot be judged · The measured flows do not cover the flows corresponding to the guaranteed flow and guaranteed head
Some points have negative head · The pressure readings or units are wrong
Test report and saving
Print test report
Click “Print test report” to generate an A4 report: test information, specified speed, guarantee point and judgement, performance curve chart, converted test point table, and best efficiency point.
Save as private model
Click “Save as private model”, then enter the model, size, curve name and speed range (as a multiple of the specified speed). The fitted curves after conversion are saved as a rated-speed performance table in Private models. After saving, the curve opens in a new window. It can then be used in data search, the filter and duty simulation, and it also appears in the Range Chart.
Notes
Results are processed according to the readings entered and the conversion and tolerance methods of the standards. Measurement uncertainty, instrument calibration and test-rig conditions are the responsibility of the testing party.
NPSH cavitation tests are not handled on this page.