Select Assist (Engineering checks)
This chapter describes the “Select Assist” panel in the right column of the Filter Search page: it runs 15 engineering checks on the current duty and selection one by one and gives a pass, fail or warning result with a comment for each. The panel is visible in all 6 steps of Filter Search and refreshes automatically whenever an input or the configuration changes.
About the panel
Check table columns
Each item in the panel occupies one row: the row starts with a result icon, followed by the name of the check, with a small comment below the name. Failed items are listed first (light red background), then warnings, then passed items; items of the same level keep their original order. On the right of the panel title, the numbers of failed, warning and passed items are counted separately.
Content · Meaning
Min · Check result for the minimum duty point; shown only when “Use Range” is selected in step 1, as the first icon at the start of the row
Nom · Check result for the nominal (design) duty point; with a single duty, the row starts with this icon only, and with “Use Range” it is the middle icon
Max · Check result for the maximum duty point; shown only with “Use Range”, as the last icon at the start of the row
Property · Name of the check
Comment · Explanation of the result or calculated data
When “Use Range” is selected, the bottom of the panel states that the icons are, in order, the results for the minimum, nominal and maximum duty points; hovering the mouse over an icon also shows which duty point it is. Sorting and counting use the worst of the three results for each item.
Click the “»” to the right of the panel title to collapse the panel; the middle area then widens. When the panel is collapsed, a vertical bar appears at the right edge of the screen (showing the numbers of failed and warning items); click it to expand the panel again. The collapsed state is saved in the current browser. On a narrow screen the panel is placed below the step content and cannot be collapsed.
Icon meanings
Icon · Meaning
Green check mark · Pass (PASS)
Red cross · Fail (FAIL); change the inputs or the selection
Orange warning triangle · Warning (WARNING): data is missing or needs attention; not necessarily an error
Grey dot · The check does not apply or has not been calculated yet
When it refreshes
It runs once as soon as the page opens, listing all 15 items;
After you change flow, slurry, head, piping, range duty or other inputs;
After a search completes and after you select a curve;
After you change impeller, material, seal, expeller, differential impeller, shaft depth, motor parameters or other configuration in step 5.
Relation to search
Before you click “Search”, if the nominal value of any of these five items — “Flow (Q)”, “Sm, Sw, Cw, Cv”, “Mass Flow Rate”, “Water (H), Slurry Head”, “Temperature” — is a red cross, a confirmation box appears; see Filter Search 4: Curve selection.
When the curve is not purchased
When the selected curve has not been purchased, the checks cannot read the curve data, so the panel shows no check rows and instead displays “Curve not purchased: checks and bearing / critical speed calculations require buying this curve”. After buying it, search again and select the curve; see Curve purchases.
Fluid checks
Flow (Q)
What it checks: whether the duty flow is valid.
Pass conditions:
Nominal: red cross if the flow is empty, 0 or cannot be calculated (for example, entered as mass flow with incomplete concentration); otherwise pass.
With “Use Range”: if the minimum or maximum flow is not entered or is 0, the corresponding column shows a warning; otherwise pass.
Inputs needed: the volume flow in step 1, or the solid mass flow and slurry concentration.
Comments:
Comment · Meaning
Passed · The flow is valid
Invalid flow rate. Please check flow rate · The flow is empty, 0 or cannot be calculated
With “Use Range”, if the minimum or maximum flow is not entered, the corresponding column shows a warning icon and “Minimum flow is invalid” or “Maximum flow is invalid” is appended to the nominal comment, e.g. “Passed; Maximum flow is invalid”.
How to fix a failure: enter a flow greater than 0 in Filter Search 1: Fluid details; when entering mass flow, also check the concentration and SG.
Sm, Sw, Cw, Cv
What it checks: whether the slurry SG Sm, liquid SG Sw, concentration by weight Cw, concentration by volume Cv and solids SG S of the slurry are complete and reasonable.
Pass conditions:
1. Slurry type “Water”: passes directly.
2. Sw must satisfy 1.0 ≤ Sw < 1.4; otherwise red cross.
3. Red cross if any of S, Sm, Cv, Cw is empty, 0 or cannot be calculated (except for two solid mixtures, whose parameters come from presets).
Inputs needed: the slurry type, the known slurry condition pair (e.g. S, Cw) and its values, and the liquid SG in step 1.
Comments:
Comment · Meaning
Water conditions · The slurry type is water; no slurry parameters to check
Passed · The slurry parameters are complete
Sw is out of range. Specify Sw between 1.0 and 1.4 · The liquid SG is not between 1.0 and 1.4
Please check mixture properties S, Sm, Cw & Cv · A parameter is empty or 0
How to fix a failure: the concentration of a single solid slurry cannot be 0; if it really is clear water, change the slurry type to “Water”.
Mass Flow Rate
What it checks: whether the solid mass flow is valid.
Pass conditions: passes directly when the slurry type is water or a two solid mixture; otherwise the mass flow must be greater than 0 and the particle size d50 must be valid.
Mass flow (t/h) = Q (L/s) × 0.036 × Sm × Cw (%)
Example: Q = 50 L/s, Sm = 1.3, Cw = 35%, mass flow = 50 × 0.036 × 1.3 × 35 ≈ 81.9 t/h.
Comments:
Comment · Meaning
Passed · The mass flow is valid
Invalid Mass Flow Rate. Check mass flow rate and d50 · The mass flow is 0 or cannot be calculated
How to fix a failure: check the flow, the concentration (mass flow is 0 when Cw is 0) and d50.
Water (H), Slurry Head
What it checks: whether the slurry head and the corresponding water head are both greater than 0.
Water head H = slurry head / HR
Pass conditions: passes only if both are valid and greater than 0. The slurry head is 0 initially, so this item shows a red cross as soon as the page opens; this is normal.
Inputs needed: the slurry head in step 2 (entered manually with “Define”, calculated from piping with “Calculate”), and HR.
Comments:
Comment · Meaning
Passed · The head is valid
Check water and slurry head · The head is 0, empty or cannot be calculated
How to fix a failure: enter the head in Filter Search 2: Head details, or choose “Calculate” and fill in the suction and discharge piping completely.
Temperature
What it checks: whether the slurry temperature is reasonable.
Pass conditions: red cross when the temperature is below 0 °C; otherwise pass. If no temperature is entered, 20 °C is used.
Comments:
Comment · Meaning
Passed · The temperature is reasonable
Check temperature · The temperature is below 0 °C
NPSHa
What it checks: whether the net positive suction head available (NPSHa) is enough to avoid cavitation.
Applies to: horizontal pumps only; vertical and submersible pumps pass directly.
Inputs needed: the suction piping in step 2 (inner diameter, equivalent length, suction static head) or “Override NPSHa”; once a curve is selected, the curve's net positive suction head required (NPSHr) at the duty point is also used.
Pass conditions:
No NPSHa (no suction piping and no override, or NPSHa is 0): warning; NPSHa is not checked.
A curve is selected and it gives an NPSHr (single duty): red cross if NPSHa < NPSHr; otherwise pass.
No curve selected, or the curve has no NPSHr: judged by rule-of-thumb thresholds: NPSHa < 1 m red cross; 1 m < NPSHa < 3 m red cross (possible cavitation); NPSHa > 3 m pass.
With “Use Range”, the system calculates NPSHa from the suction piping separately at minimum and maximum flow. If a curve is selected and gives an NPSHr, all three duty points are compared with NPSHr, and points with NPSHa < NPSHr get a red cross; once the nominal point passes, the three duty points are then judged against the 1 m / 3 m thresholds above. A point that fails at any stage keeps its red cross, and the comment lists all failure reasons separated by “;”.
Example: the suction piping gives NPSHa = 4.2 m and the selected curve has NPSHr = 5.0 m at the duty point, so NPSHa < NPSHr: red cross, comment “NPSHr > NPSHa. Check NPSHa”.
Comments:
Comment · Meaning
Passed · NPSHa meets the requirement
(blank, nominal shows a check mark) · Compared with NPSHr and passed, or NPSHa is exactly 1 m or 3 m
NPSHa Ignored. · NPSHa is not checked for vertical and submersible pumps
NPSHa will be ignored. · No usable NPSHa
NPSHr > NPSHa. Check NPSHa · Single duty: NPSHa is less than the curve's NPSHr
NPSHr > NPSHa. Check nominal duty · Range duty: NPSHa at the nominal point is less than NPSHr
NPSHr > NPSHa. Check NPSHa at minimum duty / NPSHr > NPSHa. Check NPSHa at maximum duty · Range duty: NPSHa at the minimum or maximum duty point is less than NPSHr
NPSHa is less than 1 · NPSHa is less than 1 m (single duty)
NPSHa is less than 1 at minimum duty / NPSHa is less than 1 at maximum duty / NPSHa is less than 1 at nominal duty · Range duty: NPSHa at that duty point is less than 1 m
Pump may cavitate · NPSHa is between 1 and 3 m; the pump may cavitate (single duty)
Pump may cavitate at minimum duty / Pump may cavitate at maximum duty / Pump may cavitate at nominal duty · Range duty: NPSHa at that duty point is between 1 and 3 m
How to fix a failure: raise the sump level (increase the suction static head), shorten the suction pipe or enlarge its diameter, reduce suction fittings; or choose a pump with lower NPSHr (larger size, lower speed).
Suction Pipe Velocity
What it checks: whether the velocity in the suction pipe is above the settling velocity of the slurry, so that particles do not settle and block the pipe.
Applies to: horizontal pumps only; vertical and submersible pumps have no suction pipe and show “N/A” (if d50, S, Cv or the pipe details are incomplete, the corresponding message from the table below is still shown first).
Inputs needed: d50, S, Cv (for the settling velocity); suction pipe inner diameter and equivalent length, and inner diameter and equivalent length of discharge section 1 (all must be entered to count as “pipe details”).
Pass conditions: pass if pipe velocity ≥ settling velocity; otherwise red cross. By default the settling velocity is calculated with the Durand formula (when the first step's “Settling velocity method” is set to “Durand for pipes ≤200 mm, Kaev formula for >200 mm”, pipe sections with an inner diameter greater than 200 mm use the Kaev formula instead; see Settling velocity method); for non-Newtonian slurries the critical velocity is used instead:
Pipe velocity v = Q / (π × D² / 4)
Settling velocity VL = FL × √(2 × g × D × (S − 1))
where FL is the settling velocity factor looked up from d50 and Cv, and D is the pipe inner diameter (m).
Example: Q = 50 L/s, suction pipe inner diameter 150 mm, so v = 0.05 / (π × 0.15² / 4) ≈ 2.83 m/s; with FL = 1.34 and S = 2.65, VL = 1.34 × √(19.62 × 0.15 × 1.65) ≈ 2.95 m/s. v < VL: red cross.
With “Use Range”, the minimum and maximum flows are each judged against the same settling velocity.
Comments:
Comment · Meaning
Passed · The velocity is above the settling velocity
Using water conditions · The slurry type is water; settling is not an issue
Using two solid mixture · This check is not done for two solid mixtures
No pipe details. Pipe velocity cannot be calculated · The suction or discharge piping is incomplete; this item is a warning
Settling velocity cannot be calculated.Check d50, S & Cv · d50, S or Cv is empty or 0
N/A · Vertical and submersible pumps
Check suction pipe inner diameter and suction static head · The suction pipe inner diameter or suction static head is invalid
Settling velocity = 2.95 m/s, pipe velocity = 2.83 m/s. Pipe velocity is below settling velocity; check suction pipe size and mixture properties · Single duty: the pipe velocity at nominal flow is below the settling velocity (example values); with “Use Range” the nominal value is a red cross and the comment lists only the messages for the minimum/maximum duty points
Passed; Pipe velocity is below settling velocity at the minimum duty point · Nominal passes, but at minimum flow the pipe velocity is below the settling velocity (likewise for maximum flow, shown as “Pipe velocity is below settling velocity at the maximum duty point”)
How to fix a failure: reduce the suction pipe diameter to increase the velocity; or check whether d50, S or Cv was entered too high.
Discharge Pipe Velocity
What it checks: whether the velocity in each discharge section is above the settling velocity.
Inputs needed: as for the suction pipe velocity; the discharge pipe can have several sections, each using its own inner diameter to calculate the settling velocity, and sections with “Override settling velocity” ticked use the entered value.
Pass conditions: the same as for the suction pipe velocity (pass if v ≥ VL); vertical and submersible pumps are checked too. With several discharge sections, each section is judged separately, and the check fails if the velocity in any section is below that section's settling velocity; the velocity and settling velocity of each section can be viewed in the section list in step 2, where sections below the settling velocity are marked in red.
Comments:
Comment · Meaning
Passed · The velocity is above the settling velocity
Using water conditions / Using two solid mixture · As for the suction pipe velocity
No pipe details. Pipe velocity cannot be calculated · The piping is incomplete; warning
Settling velocity cannot be calculated.Check d50, S & Cv · The slurry parameters are incomplete
Discharge pipe sections are missing · There are no discharge sections
Check discharge section inner diameters and equivalent length (TEL) · The inner diameter or equivalent length of discharge section 1 is invalid
Settling occurs in the discharge pipe at nominal duty. Check discharge pipe sections · Single duty: settling occurs in the discharge pipe
Settling occurs in the discharge pipe. Check discharge pipe sections for all duties · Range duty: settling occurs at one of the duty points (minimum, nominal or maximum)
How to fix a failure: reduce the discharge pipe inner diameter, or adjust the diameter of each section so that the velocity in every section is above the settling velocity. See Filter Search 2: Head details.
Selection Checks
CurveVersion
What it checks: whether a curve has been found by the search and selected.
Pass conditions:
No search results (including not yet searched): warning;
Results exist but no curve is selected: red cross;
A curve is selected: pass; the comment shows the selected pump and curve.
Comments:
Comment · Meaning
No curves available for your flow system head. Check your flow and system head · Not yet searched, or no curve in the search covers the duty
Curve selection required · There are results but none is selected
Pump: size, Curve: name · Selected; shows the pump size and curve name
How to fix a failure: search and click a curve to select it in Filter Search 4: Curve selection.
Duty Speed
What it checks: whether the predicted speed exceeds the normal maximum allowable speed of the curve family.
Pass conditions: checked only after a curve is selected.
Allowable speed limit = maximum speed of the curve family × 1.1
Pass (blank comment) if the predicted speed is below the limit; otherwise warning. With “Use Range”, the predicted speeds of the minimum and maximum duty points are judged separately.
Example: maximum speed of the curve family 1000 r/min, limit 1100 r/min; a predicted speed of 1150 r/min gives a warning.
Comments:
Comment · Meaning
(blank) · No curve selected, or passed
WARNING: speed exceeds the normal maximum allowable speed; suitable for LIGHT DUTY only · The speed at the nominal duty exceeds the normal maximum allowable speed; suitable for light-duty service only
WARNING: speed at minimum duty exceeds the normal maximum allowable speed; suitable for LIGHT DUTY only · The speed at the minimum duty point exceeds the limit
WARNING: speed at maximum duty exceeds the normal maximum allowable speed; suitable for LIGHT DUTY only · The speed at the maximum duty point exceeds the limit
How to fix a failure: choose a larger pump to lower the speed; overspeed operation is particularly unsuitable for highly abrasive duties.
Tip speed
What it checks: whether the peripheral speed of the impeller exceeds the value allowed for the selected impeller material. The higher the speed and the larger the impeller, the faster the wear.
Tip speed (m/s) = π × D × n / 60
where D is the impeller diameter (m) and n is the predicted speed (r/min).
Example: impeller diameter 500 mm, predicted speed 1000 r/min, tip speed = 3.1416 × 0.5 × 1000 / 60 ≈ 26.18 m/s. If the limit of the material is 30 m/s, it passes.
Pass conditions: pass if 0 < tip speed < material limit; otherwise red cross. With “Use Range”, the minimum and maximum duty points are judged separately.
Inputs needed: a selected curve with a predicted speed; the impeller and impeller material in step 5.
Comments:
Comment · Meaning
Unable to obtain speed for tip speed check · No predicted speed (no curve selected, or the duty is outside the curve)
Please select a curve then configure impeller · No impeller selected
Missing impeller material code · No impeller material selected
Missing impeller diameter · The selected impeller has no diameter data
No tip speed entry for the selected impeller material · The material has no tip speed limit
Tip speed 26.18 m/s; maximum tip speed for material XX = 30.00 m/s · Calculated tip speed and the maximum allowable tip speed of material XX (example values); it passes when the nominal icon is a check mark
Tip speed 32.50 m/s; maximum tip speed for material XX = 30.00 m/s; Tip speed check failed · The tip speed at the nominal duty exceeds the limit
“; Tip speed check failed at minimum duty” or “; Tip speed check failed at maximum duty” appended to the above · Range duty: the minimum / maximum duty point exceeds the limit
The first five are warnings.
How to fix a failure: choose an impeller material with a higher allowable tip speed, or a larger pump running at lower speed.
Casing Pressure
What it checks: whether the working pressure at the pump discharge is below the rated working pressure of the casing (including the liner combination).
Working pressure (kPa) = Sm × 1000 × 9.81 × slurry head (m) / 1000
The slurry head is the total head (for multiple pumps in series, the head of the whole set).
Example: Sm = 1.4, slurry head 40 m, working pressure ≈ 549 kPa; with a rating of 1000 kPa it passes.
Pass conditions: pass if the working pressure is less than the rated working pressure; when the same material combination has several ratings, it passes if any rating is met. With “Use Range”, the minimum and maximum heads are judged separately.
Inputs needed: a selected curve (pump); the casing material (automatic) and the liner material in step 5.
Comments:
Comment · Meaning
More information required. · No curve selected or no casing material (warning)
No pressure rating. · No rated pressure data for this pump and material combination (warning)
Calculated pressure 549 kPa; maximum allowable pressure for casing material 'XX' = 1000 kPa · Calculated working pressure and the rated working pressure of the material combination (example values); a red cross in the nominal icon means the calculated pressure is not less than the rated pressure
Casing materials: A, B · The pump and material combination has several rated pressure records; only the material names are listed, and it passes if any rating is met
“; Warning: casing pressure check failed at minimum duty” appended to the above · Range duty: the minimum duty point exceeds all rated pressure records
“; Warning: casing pressure check failed at maximum duty” appended to the above · Range duty: the maximum duty point exceeds all rated pressure records
For range duties, the minimum and maximum duty points follow the same rule as the nominal point: with several rated pressure records, it passes if any record is met.
How to fix a failure: choose a liner material combination with a higher pressure rating; or use several pumps in series to reduce the head per pump.
Seal Pressure
What it checks: with a centrifugal seal, whether the pump inlet pressure does not exceed the maximum inlet pressure the expeller can seal at the duty speed.
Inlet pressure (kPa) = Sm × 1000 × 9.81 × suction static head (m) / 1000
Applies to: checked only when “Centrifugal” is selected in step 5. When the differential impeller is ticked, the duty speed is multiplied by 1.18 to calculate the expeller capacity.
Pass conditions: pass if inlet pressure ≤ maximum allowable pressure; otherwise red cross. The maximum allowable pressure can be viewed under “Expeller Curve” in step 5.
Example: Sm = 1.3, suction static head 5 m, inlet pressure ≈ 63.8 kPa; the expeller's maximum allowable pressure at the duty point is 120 kPa, so it passes.
Inputs needed: a selected curve; a centrifugal seal; expeller data; the suction static head in step 2 (must not be empty or 0).
Comments:
Comment · Meaning
(blank) · No curve selected, or not enough curve data for the calculation
N/A · Not a centrifugal seal
No expeller data available for this impeller. · The selected pump/impeller has no expeller; red cross
Invalid static inlet head. Inlet pressure check cannot proceed · The suction static head is empty or 0; warning
Passed · Single duty: the inlet pressure does not exceed the allowable value
Expeller is not suitable · The inlet pressure at the nominal duty exceeds the allowable value
Expeller is not suitable for minimum duty · Range duty: the minimum duty point does not meet it
Expeller is not suitable for maximum duty · Range duty: the maximum duty point does not meet it
Expeller is not suitable for minimum duty; not suitable for maximum duty · Both occur together
Tip: With “Use Range”, once the nominal duty passes, the nominal column stays blank, and the minimum and maximum columns are judged by the inlet pressure at their own duty points.
How to fix a failure: switch to the Hi-Seal expeller, tick the differential impeller, or lower the suction static head; if it still fails, use a gland seal or mechanical seal instead.
Critical Speed
What it checks: for vertical and submersible pumps at the selected shaft depth, whether the duty speed avoids the first critical speed of the shaft, and whether shaft stresses and bearing life meet the requirements.
Applies to: vertical and submersible pumps only; horizontal pumps show “N/A”.
Inputs needed: a selected curve; the impeller, frame, bearing assembly and shaft material in step 5; the shaft depth selected in the “Critical Speed” tab.
Pass conditions (all must be met to pass):
Predicted speed N < 0.8 × NCr1, or 1.2 × NCr1 < N ≤ 1.6 × NCr1 (NCr1 is the first critical speed);
At the selected shaft depth, the dry end, wet end and thread stresses are all below 100%;
The dry end and wet end L10 lives are both at least 5000 h.
For the rules and examples see Bearing Life, Critical Speed and Flange Load.
Comments:
Comment · Meaning
N/A · Horizontal pump, or no critical speed data yet (frame/bearing assembly not determined)
Select shaft depth from the critical speed check list. · No shaft depth selected; red cross
Passed · The selected shaft depth meets all conditions
Check critical speed, bearing life and stresses for shaft depth N (see the Critical Speed tab) · Shaft depth N does not meet the conditions; check in the “Critical Speed” tab whether the problem is resonance, stress or life
How to fix a failure: choose another shaft depth in the “Critical Speed” table; or change the shaft material or bearing assembly.
Motor Power
What it checks: whether the entered motor power is greater than the recommended motor power.
Recommended motor power = slurry shaft power × safety factor
The slurry shaft power already includes HR/ER and the seal derating; for the calculation see Filter Search 5: Configuration.
Pass conditions: pass if recommended motor power < motor power; otherwise red cross.
Example: slurry shaft power 32.7 kW, safety factor 1.2, recommended motor power ≈ 39.2 kW. Entering 37 kW gives a red cross with the comment “Failed: motor power 37 kW is lower than the recommended motor power of 39 kW”; entering 45 kW passes.
Inputs needed: the motor power and safety factor in the “Bearing Life” (or “Critical Speed”) tab; a selected curve with a predicted speed and efficiency.
Comments:
Comment · Meaning
No motor selected · No motor power entered; warning
Invalid pump speed or efficiency from performance curve · No predicted speed or efficiency; warning
Passed · The motor power is sufficient
Failed: motor power N kW is lower than the recommended motor power of N kW · The entered motor power is below the recommended motor power (values rounded)
How to fix a failure: choose the next larger motor; or check whether the safety factor is too high.
Liner Speed, Frame Power (private models)
These two rows appear at the end of the check table only when a private model is selected and its “Nameplate spec tables” have the corresponding values entered; catalog curves do not have these rows.
Liner Speed: the duty speed (with “Use Range”, the minimum, nominal and maximum duty points) is compared with the rated max speed of the liners.
Case · Icon · Comment
Does not exceed the rated max speed of any liner · Pass · Passed
Exceeds only some liners · Pass · “Speed N r/min is above the rated max speed of these liners: Polymer 900”; lists the liners that cannot be used
Exceeds all liners · Warning · As above, lists all liners
No predicted speed · Warning · Unable to obtain speed for the liner speed check
Frame Power: the slurry shaft power (same calculation as the “Motor Power” check, without the safety factor) is compared with the rated power of the frames.
Case · Icon · Comment
Does not exceed the rating of any frame · Pass · Passed
Exceeds only some frames · Pass · “Absorbed power N kW is above the rating of these frames: G 600”; lists the frames that cannot be used
Exceeds all frames · Warning · As above, lists all frames
No predicted speed or efficiency · Warning · Invalid pump speed or efficiency from performance curve
Inputs needed: enter the rated max speed of the liners and the rated power of the frames in the liner and frame tables under “Construction data (optional)” on the private model edit page; see Private models.
How to fix a warning: lower the speed (choose a pump or impeller one size larger); or choose liners or frames with higher ratings and add them to the private model.
FAQ
Red crosses as soon as the page opens
Initially the head is 0 and no search has been run or curve selected, so items such as “Water (H), Slurry Head” and “CurveVersion” show red crosses or warnings; they turn to pass one by one as you fill in the steps.
Blank comment but a check mark icon
Some checks write no comment when they pass (e.g. Duty Speed, and NPSHa when it passes the comparison with NPSHr); this is normal.