Motor Selection & Analysis

Motor Selection & Analysis chooses a motor from the pump's shaft power and speed, and answers the questions that come up at selection time: what load factor, efficiency, power factor and current the motor runs at under this duty; whether it overloads anywhere across the full flow range; whether direct-coupled speed matches, and what belt or gearbox ratio or VFD frequency is needed; how much the annual electricity bill differs between IE2, IE3 and IE4; and whether direct-on-line, star-delta, soft starter or VFD starting can get the pump moving, with the starting time and current.

This chapter describes the requirements and entry points, every input and result of the five tabs, the calculation methods, the meaning of the messages, My Motor Library, and how the page works with Duty Simulation and Filter Search. The page is under “Motor Selection & Analysis” in the left Workspace.

Requirements and access

Requirements

“Recommendation” is available to all signed-in users.

“Motor Characteristics”, “Operating Analysis”, “Starting Check” and “My Motor Library” are Premium features, and members of an enterprise team can use them too. When a regular user opens one of these tabs, the message ““Motor Selection & Analysis” is a Premium feature” and a “Get Premium” button are shown. See Premium membership.

A regular user can still see the motors entered earlier in “My Motor Library”, but cannot create, copy or import motors.

How to open

Click “Motor Selection & Analysis” in the left Workspace.

In Duty Simulation, on the “Motor & energy” tab, choose “Per motor” and then click “Detailed analysis & start-up check →”. This opens “Operating Analysis” on this page, carrying the current simulation's shaft power, speed, drive type, impeller diameter, pump efficiency, flow and pump power curve. The top of the page shows “Shaft power, speed, drive type, impeller diameter and pump power curve were imported from duty simulation ‘…’.”

In the motor selector at the top left of “Operating Analysis”, “Motor Characteristics” or “Starting Check”, click “Manage Motor Library” to switch to “My Motor Library”.

The page remembers the last tab and the inputs, and restores them the next time it is opened.

Standard motors and data sources

Standard motors

“Standard motors” generates a typical three-phase squirrel-cage induction motor from its efficiency class, rated power, poles, voltage and frequency:

Parameter · Source

Rated efficiency · The minimum efficiency specified in IEC 60034-30-1:2014 (IE1–IE4, 2/4/6/8 poles, 0.12–1000 kW); 50 Hz and 60 Hz are each taken from their own table, and ratings not in the table are interpolated linearly on a logarithmic power scale; for the 60 Hz values, see Voltage and frequency

Power factor, locked-rotor current ratio, locked-rotor torque ratio, breakdown torque ratio, no-load current ratio · Typical values from common low-voltage motor catalogues, varying with power and poles

Rated speed · Calculated from a typical rated slip; the higher the efficiency, the smaller the slip

Moment of inertia · Typical value, varying with power and poles

Frame size · Corresponds to the common low-voltage series (IEC 72), for reference only; above 315 kW, 400 or 450 is shown

The efficiency of a standard motor is the lower limit for its class; actual products are usually slightly higher. The other parameters are typical values, and the motor manufacturer's catalogue governs. For precise calculations, enter the manufacturer's catalogue data in My Motor Library.

Efficiency classes

Class · Name

IE1 · Standard Efficiency

IE2 · High Efficiency

IE3 · Premium Efficiency

IE4 · Super Premium Efficiency

Power ratings

0.12, 0.18, 0.25, 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90, 110, 132, 160, 185, 200, 220, 250, 280, 315, 355, 400, 450, 500, 560, 630, 710, 800, 900, 1000 kW.

Motors of 0.75 kW and below have a low power factor and large slip, and their rated speed is noticeably below the synchronous speed (for example, a 4-pole 0.25 kW motor runs at about 1380 r/min), so check speed matching when direct-coupling.

Voltage and frequency

Voltage can be selected from the common levels from 220 to 11000 V, or entered directly; frequency is 50 Hz or 60 Hz. Frequency determines the synchronous speed (synchronous speed = 120 × frequency ÷ poles), and also determines which efficiency table is used and how the efficiency class is judged.

The minimum efficiency at 60 Hz differs from that at 50 Hz (higher for most power ratings). The power ratings follow horsepower (for example, 3.7 kW, 150 kW), and ratings not in the table are likewise interpolated logarithmically:

IE2, IE3, IE4: taken from the 60 Hz table of IEC 60034-30-1:2014.

IE1: 2-, 4- and 6-pole motors of 0.75–375 kW use the 60 Hz limits of IEC 60034-30:2008; 8-pole motors and motors of 0.75 kW and below have no citable values in the standard, so they are estimated from the 50 Hz IE1 value using the 60 Hz to 50 Hz loss ratio of an IE2 motor of the same power. These are estimated values.

For motors at 60 Hz entered in “My Motor Library”, a blank rated efficiency is filled in from the 60 Hz table, and the efficiency class is also judged from the 60 Hz table. The same efficiency value may be judged as different classes at 50 Hz and 60 Hz.

Recommendation

Recommends a motor power rating from the pump's shaft power and speed, and lists how the 2, 4, 6 and 8 pole motors match the pump speed.

Pump shaft power (duty)

Shaft power of each pump at the design duty, kW. Required.

Maximum shaft power

Optional. Maximum shaft power over the full flow range or at the highest speed, kW. When entered, the recommended motor is guaranteed not to overload over the full curve.

Pump speed

Operating speed of the pump, r/min. Used to check the direct-coupled speed match, and to calculate the gear ratio or VFD frequency. If it is not entered, the speed match cannot be checked: the rows of the table show “Pump speed not entered, so the speed match cannot be checked; the common 4-pole motor is shown”, and the ★ is placed on the 4-pole row.

Drive type

Option · Description

Direct coupling · Motor and pump run at the same speed; the rated speed of the motor should be close to the pump speed

Belt drive · Gives the ratio of motor speed to pump speed (0.6–5 is the reasonable range)

Gearbox · Gives the reduction ratio of motor speed to pump speed (1.2–12 is the reasonable range)

VFD direct · Motor is directly coupled; the VFD adjusts the speed to the pump speed and gives the output frequency

Drive efficiency

Optional, %. If left blank: direct coupling 100%, belt drive 96%, gearbox 97%.

Power margin factor

Default 1.15, range 1–2.

Efficiency class, voltage and frequency

Efficiency class (default IE3), voltage (default 380 V) and frequency (default 50 Hz) of the recommended motor.

Recommendation result

Required motor power = max(duty shaft power × power margin factor, maximum shaft power) ÷ drive efficiency

The smallest standard power rating not smaller than the required power is selected and shown as “Recommended motor power: x kW”.

For VFD direct coupling where the pump speed is below the rated speed of the motor, the motor is selected by torque. Below base frequency the motor can only deliver its rated torque, so the usable power = rated power × pump speed ÷ rated speed of the motor, and the required rated power is scaled up accordingly. The power rating can therefore differ between pole counts; “Recommended motor power” shows the power of the row marked ★. A pole count that slows the pump down too much, where no standard rating is large enough, is not listed.

The table has one row per pole count:

Column · Meaning

Poles · The recommended row has a ★ and is highlighted

Rated power, rated speed, frame size · Parameters of the standard motor with that pole count

Load factor · Duty shaft power ÷ drive efficiency ÷ rated power; for VFD direct coupling it is calculated for VFD conditions, see Operating Analysis

Efficiency at duty % · Efficiency of the motor at this load factor

Speed match · Direct coupling: “Direct-coupled speed match (deviation x%)” or “Speed mismatch (deviation x%)”; a deviation within 3% is a match. Belt drive and gearbox: “Gear ratio x”. VFD: “VFD x Hz”.

Recommendation rules: direct coupling takes the pole count with the smallest speed deviation within 3%; VFD takes the pole count whose output frequency is below the line frequency and closest to it; belt drives and gearboxes prefer 4 poles, then 6, 2 and 8. If no pole count is suitable, no ★ is shown.

Click “Use this” on a row to switch to “Operating Analysis” with that motor and the same duty.

When the required power exceeds 1000 kW, the message “Required power exceeds the standard motor range (1000 kW). Please enter a high-power motor in My Motor Library.” is shown.

Motor Characteristics

Select a motor on the left; the load and torque characteristics of the motor are shown on the right.

Motor selection

Standard motor: select efficiency class, rated power, poles, voltage and frequency.

My Motor Library: choose one of the motors already entered from the drop-down list (when a team is active, motors shared by teammates are included, with the creator noted after each).

Key parameters

Item · Description

Efficiency class achieved · The rated efficiency is compared with IEC 60034-30-1; the minimum efficiency of IE1–IE4 is listed below, and the class the motor achieves is highlighted; below IE1 “<IE1” is shown

Rated efficiency, rated power factor, rated current · If the rated current is not entered, it is calculated as I = P ÷ (√3 × U × η × cosφ)

Rated speed · The small text after it is the synchronous speed

Rated slip · (synchronous speed − rated speed) ÷ synchronous speed

Rated torque · Tn = 9550 × P ÷ n, N·m

Locked-rotor current ratio, locked-rotor torque ratio, breakdown torque ratio · Multiples of the rated current and rated torque

Moment of inertia · Motor rotor, kg·m²

Frame size ·

Peak efficiency point · Load factor at which the efficiency is highest

The basis of the calculation is explained below. For a standard motor: “Standard motor efficiency uses the minimum values specified in IEC 60034-30-1. Power factor, current ratio, torque ratio, moment of inertia and frame size are typical values for common low-voltage motors; refer to the motor manufacturer's catalog for actual figures.” For a motor with measured load points: “Part-load characteristics are interpolated from the measured load points entered.” For a motor with only rated parameters entered: “Part-load characteristics are estimated from the entered rated parameters using a loss model.”

Load characteristics

Four small charts with the load factor from 0 to 125% on the horizontal axis: efficiency (the dashed line is the minimum efficiency of the class this motor achieves), power factor, current (A) and speed (r/min).

Without measured data, the loss model is used:

Rated loss L = P × (1/η − 1)
η(x) = x·P ÷ (x·P + L × (k0 + (1 − k0) × x²))

x is the load factor, and k0 is the share of losses that do not vary with load (iron and mechanical losses): 0.30 below 10 kW, 0.35 for 10–100 kW, and 0.40 above 100 kW.

Reactive power Q(x) = Q0 + (Qn − Q0) × x²      (Q0 = no-load magnetizing reactive power)
Power factor = P1 ÷ √(P1² + Q²)
Current = √(P1² + Q²) ÷ (√3 × U)
Slip ≈ rated slip × x

When measured load points exist, the values between them are linearly interpolated, and outside the measured range the curve joins the shape of the model curve. If only efficiency was entered without power factor, the power factor still comes from the model.

Torque and current vs speed

Two small charts; the horizontal axis is speed as a percentage of synchronous speed, at full voltage:

Torque (multiple of rated torque): between the rated point and the breakdown torque point, the Kloss formula is used; between the breakdown torque point and zero speed, the curve passes smoothly through the minimum (pull-up) torque to the locked-rotor torque. The curve passes through the rated point, the breakdown torque point and the locked-rotor point.

Current (multiple of rated current): at zero speed it is the locked-rotor current ratio; at rated speed it is 1; near synchronous speed it approaches the no-load current.

A vertical dashed line “Rated” marks the rated speed.

Load point table

Lists the output power, input power, efficiency, power factor, current, speed and torque at 25%, 50%, 75%, 100% and 125% load.

Operating Analysis

Select a motor on the left and enter the duty; the right side shows the motor's operating condition, the efficiency chain, electricity cost and the efficiency class comparison. Results recalculate automatically as the inputs change.

Duty inputs

Parameter · Unit · Description

Pump shaft power (duty) · kW · Per pump, required

Maximum shaft power · kW · Optional; used for the “Maximum shaft power exceeds the motor's allowable value” check

Pump speed · r/min · Used for the speed match, gear ratio and VFD frequency

Drive type · · Same as Recommendation

Drive efficiency · % · If blank, the default for the drive type is used

With VFD · · For direct coupling, belt drive and gearbox, can be turned on to indicate supply through a VFD; for “VFD direct”, the VFD calculation is always used

VFD efficiency · % · Default 97

Pump efficiency · % · Optional; when entered, the overall unit efficiency is calculated

Flow · m³/h · Optional; when entered, the specific energy is calculated

Operating hours per year · h · Default 6000

Electricity price (per kWh) · · Default 0.7; the box on the right is the currency symbol

Grid emission factor · kg/kWh · CO₂ emitted per kWh of electricity; default 0.57

Service life · yr · Default 10; used to calculate the electricity cost and savings over the service life

When imported from Duty Simulation, the pump power curve is imported too, and the lower left notes “Full-curve overload check uses the pump power curve from duty simulation (n points).”

Check conclusion

The top of the right side lists the conclusions. When everything is normal it shows “Motor load, speed and full-curve checks are all within limits”; otherwise each issue is listed (✕ for fail, ! for caution), with the meanings in Operating analysis messages.

Operating data

Item · Description

Load factor · Motor output power ÷ rated power; motor output power = pump shaft power ÷ drive efficiency

Motor efficiency, power factor, current · Values at this load factor

Input electrical power · Motor input power ÷ VFD efficiency (not divided when there is no VFD)

Annual energy use · Input electrical power × operating hours per year

Annual electricity cost · Annual energy use × electricity price

Annual CO₂ emissions · Annual energy use × emission factor ÷ 1000, in tonnes

Specific energy · Input electrical power ÷ flow, kWh/m³ (shown only when flow is entered)

n-year electricity cost · Annual electricity cost × service life

With VFD operation, the motor efficiency is calculated for VFD conditions: copper losses vary with the square of the torque, iron and mechanical losses decrease with roughly the 1.5th power of speed. Below base frequency the load factor is based on torque (constant-torque region); above base frequency the motor enters the constant-power region, where the available torque falls in inverse proportion to speed, and the load factor = torque load factor × speed ratio, which is approximately the power load factor.

Efficiency chain

Overall unit efficiency = pump efficiency × drive efficiency × motor efficiency × VFD efficiency

If no pump efficiency is entered, only the drive efficiency (drive × motor × VFD) is shown.

Speed and power

Item · Description

Motor output power · Pump shaft power ÷ drive efficiency

Motor speed (line frequency) · The actual speed at this load

Required gear ratio (motor/pump) · Shown for belt drive and gearbox

VFD output frequency · Shown with VFD; = frequency × (required motor speed + slip speed at this load) ÷ synchronous speed

Speed deviation · Shown for direct coupling; (motor speed − pump speed) ÷ pump speed

Allowable pump shaft power · Rated power × service factor × drive efficiency; for VFD operation at reduced speed, further multiplied by motor speed ÷ rated speed (below base frequency the motor can only deliver its rated torque, so the usable power falls with speed)

Maximum shaft power over full curve · Shown when a pump power curve is available, followed by the corresponding load factor; highlighted in red when above the allowable value

Peak efficiency point ·

The two small charts below show efficiency and current against load factor; a vertical dashed line marks the current duty.

Efficiency class comparison

IE1–IE4 standard motors with the same power and poles (when the selected motor is from the library, one more row, “Selected motor”, is added), all calculated at this duty's load factor:

Column · Description

Rated efficiency %, efficiency at duty % ·

Input electrical power kW, annual energy use, annual electricity cost ·

Annual savings vs IE2 · IE2 annual electricity cost − annual electricity cost of this row; a positive number is a saving (green), a negative number is extra cost (red)

Savings vs IE2 over n years · Annual savings vs IE2 × service life

Annual CO₂ emissions · Tonnes

The horizontal bar chart below shows the annual electricity cost for each class.

Operating analysis messages

Message · Meaning and action

Duty exceeds motor rated power (including service factor); motor overloaded · Use a motor one size larger

Duty exceeds rated power; using service factor margin · A motor with a service factor above 1 allows short-time or continuous small overloads; leaving some margin is recommended

Full-curve overload check failed: motor overloaded at flow above x m³/h · When the operating point moves to the right (for example, as pipe resistance decreases or the level rises), the motor overloads; enlarge the motor or limit the flow

Maximum shaft power exceeds the motor's allowable value · The entered maximum shaft power exceeds the allowable pump shaft power at rated speed (rated power × service factor × drive efficiency)

Load factor below 50%; motor oversized, efficiency and power factor are low · Consider a motor one size smaller (not shown for VFD operation)

Load factor below 70%; motor slightly oversized ·

With direct coupling, motor speed differs from pump speed by x%; change poles, drive type or use a VFD · Direct-coupled deviation above 3%

VFD output x Hz is above line frequency; operating in the field-weakening constant-power region · Above base frequency the motor output torque falls with frequency; pay attention to power

VFD output x Hz is low; watch motor cooling during long operation · Below half of base frequency

Starting Check

Integrates step by step the motor torque–speed characteristic and the pump load torque to simulate the starting process of the four starting methods.

Load and inertia

Parameter · Unit · Description

Pump shaft power at end of start · kW · For open-valve start, enter the duty shaft power (leave blank to use the shaft power from Operating Analysis); for closed-valve start, enter the shut-off point power

Pump speed · r/min · Shared with Operating Analysis

Drive type · · Shared with Operating Analysis; for belt drive and gearbox, the gear ratio is the motor rated speed ÷ pump speed

Breakaway torque · % · Share of the end-of-start load torque that the pump needs at zero speed; default 15. Clear-water pumps are generally 5–10; slurry pumps 10–30

Pump moment of inertia · kg·m² · Pump shaft side, including the impeller, shaft, coupling half, etc.

Impeller outer diameter · mm · If the pump moment of inertia is not entered, it is estimated from the impeller outer diameter

Slurry pump metal / rubber-lined impeller · · When on, estimated as a heavy slurry pump impeller (J ≈ 85 × D⁵ × 1.1); when off, estimated as a clear-water pump (J ≈ 25 × D⁵ × 1.1), D in m

Coupling / pulley inertia · kg·m² · Optional, motor shaft side

The pump load torque varies with speed:

T(n) = T0 + (Tf − T0) × (n ÷ nf)²
Tf = 9550 × pump shaft power at end of start ÷ drive efficiency ÷ motor speed at end of start
T0 = Tf × breakaway torque %

If neither the pump moment of inertia nor the impeller outer diameter is entered, the pump inertia is estimated from the motor rotor inertia (twice for slurry pumps, once for clear-water pumps); a message is shown above the results, and the starting time is for reference only.

Total moment of inertia (referred to the motor shaft) = motor rotor + pump ÷ gear ratio² + coupling / pulley.

Power supply

Parameter · Unit · Description

Transformer capacity · kVA · Optional. When entered, the grid voltage drop at starting is estimated from the transformer impedance divider

Short-circuit impedance · % · Default 6

Other voltage drop · % · Voltage drop from cables and other causes; default 0

Short-circuit capacity = transformer capacity ÷ short-circuit impedance
Terminal voltage = (1 − other voltage drop) ÷ (1 + full-voltage apparent power of motor ÷ short-circuit capacity)

Motor torque is proportional to the square of the terminal voltage, and current is proportional to the terminal voltage.

Starting method parameters

Parameter · Unit · Default · Description

Star-delta switching speed · % · 90 · Switches from star to delta when the star-connected motor has accelerated to this share of synchronous speed; if it stalls in star, it switches earlier

Soft starter initial voltage · % · 40 ·

Soft starter ramp time · s · 10 · Time for the voltage to rise from the initial value to 100%

Soft starter current limit · ×In · 3.5 · The voltage stops rising when the current reaches the limit

VFD acceleration time · s · 10 · Time to ramp from zero to the pump speed

VFD current limit · ×In · 1.5 · The maximum torque at the current limit is about √((limit² − no-load current ratio²) ÷ (1 − no-load current ratio²)) times rated torque

How each method is handled:

Method · Motor torque and current

Direct on line · Full voltage (less the grid voltage drop)

Star-delta · In star, torque and line current are both one third of direct starting; after the switching speed, it changes to delta

Soft starter · Voltage ramps up and is limited by the current limit

VFD · Follows the speed reference according to the acceleration time; if the required torque exceeds the torque corresponding to the current limit, acceleration becomes slower; above base frequency the available torque falls inversely with frequency

Results

The top shows the rated torque, end-of-start load torque, breakaway torque and total moment of inertia (the motor and pump components are in brackets; estimated values are marked “Estimated”).

Comparison table of the four methods (the selected method is highlighted; switch with the buttons above):

Column · Description

Result · ✓ Start OK / ! Caution / ✕ Fail

Starting time · Shows “—” if the motor cannot start

Starting current · Current at zero speed, A, followed by the multiple of rated current

Peak current · Peak current during starting (star-delta includes the switching surge)

Minimum acceleration margin · The minimum of (motor torque − load torque) ÷ rated torque and the speed where it occurs; not shown for VFD

Minimum grid voltage · Lowest grid-side voltage during starting; not shown for VFD

Rotor heating · Rotor heating during starting as a percentage of the reference limit (the heat of a 10 s locked rotor); with VFD starting the slip is very small, so the heating is far below that of the other methods

Notes · Messages, see the table below

Charts below: torque vs speed (available torque of the four methods and the dashed pump load torque), current vs speed, and speed and current vs time for the selected method.

Starting check messages

Message · Meaning and action

Start failed: at x% speed the motor torque is insufficient to continue accelerating · The motor torque curve intersects the load torque and the motor stalls at this speed; switch to direct starting, enlarge the motor or raise the soft starter current limit

Start failed: at zero speed the motor torque is less than the load breakaway torque · The starting method's initial torque is too low

Zero-speed torque margin insufficient (below 1.3 times breakaway torque) · If the actual breakaway torque is higher, the pump may fail to start

Accelerating torque margin is small (below 10% of rated torque); slow start ·

Starting time is long; confirm the allowable starting time with the motor manufacturer · Direct starting and star-delta above 10 s; soft starter above 20 s or 1.3 times the voltage ramp time, whichever is larger; VFD starting follows the set acceleration time with current limiting, so no duration warning is given

Starting time too long; motor may overheat or protection may trip · More than twice the time above

Rotor heating during start exceeds the reference limit (heat of a 10 s locked rotor) · Common with high-inertia loads; confirm with the motor manufacturer

Grid voltage dip during start exceeds 10% ·

Grid voltage dip during start exceeds 15%, affecting other equipment on the same grid · Use reduced-voltage starting or VFD, or enlarge the transformer

Star connection must switch before reaching 80% speed; switching current surge is large ·

VFD current limit insufficient; actual acceleration is slower than the set time · Raise the current limit or lengthen the acceleration time

Load at end of start exceeds motor rated torque · Motor is undersized. For direct starting, star-delta and soft starter, the load is judged at the motor's actual steady speed: with direct coupling and a pump speed below the motor speed, without a VFD the motor brings the pump up to motor speed, so the load torque increases with the square of speed

Pump speed requires the motor to run above synchronous speed · VFD needs to exceed base frequency

The starting check is an engineering estimate. For high-power or high-inertia units, or complex grid conditions, confirm with the motor manufacturer.

My Motor Library

Enter the motor manufacturer's catalogue or measured data for use in Motor Characteristics, Operating Analysis, Starting Check, Duty Simulation and filter selection.

Permissions and quota

Creating, copying and batch importing require Premium membership; up to 300 motors per person.

When a team is active, motors entered by teammates are visible to the whole team (the list gains a “Created by” column, and you can switch between “All (incl. team)” and “Mine only”). Creating, batch-importing, copying and editing your own motors requires the “Motor library” permission set to “Edit own”; editing and deleting teammates' motors requires “Manage all”. This permission is set separately from the private model permission; see Team Edition.

Motor library data is visible only to you and your team.

List

Lists the model, manufacturer, rated power, poles, voltage/frequency, rated efficiency, efficiency class, rated speed, frame size and number of measured points. On narrow screens, such as phones, each motor is shown as a card with the same content; in the edit form, the measured load points are also entered as a vertical group of inputs for each point. Actions:

Use this: switches to “Operating Analysis” with this motor.

Edit, Copy (copies the motor to your own account and appends “ - copy” to the name), Delete.

Create and edit

Field · Unit · Description

Model, manufacturer · · Model up to 128 characters

Poles · · 2, 4, 6 or 8

Frequency · Hz · 50 or 60

Voltage · V · 100–15000

Efficiency class · · Can be left unselected; classified automatically from the rated efficiency

Rated power · kW · Required, 0.05–20000

Rated efficiency · % · 30–99.5

Rated power factor · · 0.3–0.99

Rated speed · r/min · Must be below synchronous speed and not less than 80% of it

Rated current · A ·

Locked-rotor current ratio · ×In · 2–12

Locked-rotor torque ratio · ×Tn · 0.3–4

Breakdown torque ratio · ×Tn · 1.2–5

Minimum torque ratio · ×Tn · 0.3–4; if blank, estimated from the locked-rotor torque

No-load current ratio · ×In · 0.1–0.8

Moment of inertia · kg·m² ·

Service factor · · 1–1.5, default 1

Weight · kg ·

Frame size · ·

Notes · · Up to 1000 characters

Only rated power, poles, frequency and voltage are required; blank fields are calculated from the typical values of a standard motor with the same power and poles. Click “Fill blanks with typical values” to put the typical values into the empty boxes, then adjust them to match the catalogue.

Measured load points

Optional, up to 30. Each point takes a load factor (%) and any combination of efficiency, power factor, current and speed; load factors must not repeat. Once entered, part-load characteristics are interpolated from the measured points, which is more accurate than the model estimate.

Batch import

Click “Batch Import”, copy the table from Excel and paste it into the text box (the first row is the column names, separated by tabs, commas or semicolons). Column names:

name, maker, ratedKw, poles, frequency, voltage, ratedEff, ratedPf, ratedRpm, ratedCurrent, istIn, tstTn, tmaxTn, inertia, frame, ieClass, eff25, eff50, eff75, pf25, pf50, pf75, note

When there is no header row, the columns are read in the order above. eff25/eff50/eff75 and pf25/pf50/pf75 are the measured efficiency and power factor at 25%, 50% and 75% load (saved together with the rated efficiency and power factor as measured points at 100% load). Click “Download template” for a sample CSV. Up to 200 motors at a time; all valid rows are saved, and failed rows are listed with their row numbers and reasons.

Numbers may include units (%, A, kW, V, Hz, r/min, kg), the decimal separator may be a comma (e.g. 93,6), and the pole count may be written as 4P. Rows with unrecognized values are listed with their row numbers and column names before import; those rows are not imported, and the other rows are imported as usual. After import, the text box keeps only the rows that were not imported; after correcting them you can click “Import” again, and rows already imported are not imported twice.

Export CSV

Exports the motors in the list as a CSV in the same format, which can be edited and imported again.

Working with Duty Simulation and Filter Search

Duty Simulation: on the “Motor & energy” tab, “Motor efficiency source” can be set to “Per motor”; see Duty Simulation.

Filter Search step 5: “Select motor” next to “Motor model”; see Filter Search 5: Configuration.

Enterprise selection portal: portal customers can also click “Select motor” in step 5 of Filter Search and, besides standard motors, choose from the “Manufacturer motor library” (motors entered by the manufacturer's team, read-only). This page is not offered in the portal. See Selection portal.

Printing

Click “Print” at the top right of the page to generate an A4 report for the currently selected motor: motor parameters, load characteristic and torque characteristic charts, operating data, messages and efficiency class comparison, and the four-method starting comparison with torque and current charts. Any part not yet calculated is calculated automatically first.