Global Desalination in 2025: Capacity, Energy per Cubic Metre and High-Pressure Pump Selection for RO Plants
Desalination is shifting from an emergency supplement to a backbone of water supply in much of the Middle East and North Africa. A 2025 World Bank report on desalination in the region, drawing on the DesalData industry database, gives the 2025 capacity split, the technology mix and expectations for the next five years. China's Ministry of Natural Resources has published a national figure for 2024 on a different basis. This article combines those primary sources to show why high-pressure pumps, energy recovery and materials are the core opportunity for pump makers in reverse osmosis (RO) systems, and what that means for pump selection.
The global picture in 2025
According to the World Bank (2025), citing the DesalData database, the Middle East and North Africa held 46% of global online desalination capacity in 2025, East Asia and the Pacific 23%, North America 11% and Western Europe 7%. The five largest countries were Saudi Arabia (17.3 million m3/day), China (14.0 million), the United States (11.0 million), the United Arab Emirates (9.1 million) and Spain (5.0 million). The report expects the region to account for 63% of newly contracted capacity in 2026-2030, with roughly 1.5 to 3.5 million m3/day coming online each year in the region. "Online capacity" here covers all water sources and uses and may not match national statistics.
On technology, thermal capacity has been almost flat since 2010 and nearly all recent growth has come from membranes, mainly RO. In 2025 RO made up 65% of capacity in the Middle East and North Africa and 89% elsewhere. The report also notes a median all-in water cost of about US$0.52 per m3 for 17 RO plants awarded in the region between 2019 and 2025. Projects are getting larger: the Jordan and Morocco projects, at 822,000 m3/day each, are the largest outside the Gulf Cooperation Council states.
China: the national basis
The Ministry of Natural Resources' 2024 national seawater utilisation report, published in July 2025, counts 158 seawater desalination projects in China at the end of 2024, with a combined capacity of 2.856 million tonnes per day, up 333,000 tonnes per day from 2023. It says that one 30,000 tonne-per-day line in Tianjin now uses domestically made RO membranes, high-pressure pumps and energy recovery devices. This is a national project count for seawater desalination and is not the same basis as the 14.0 million m3/day DesalData figure for China above, so the two should not be mixed.
Where energy use per cubic metre stands
The World Bank summarises 2010-2020 estimates of about 2.5 to 5.5 kWh/m3 for seawater RO, 5.5 to 12.0 for multi-effect distillation and 9.0 to 16.0 for multistage flash. It reports that Saudi Arabia's desalination energy use fell from about 15 kWh/m3 to about 2.7 kWh/m3 in 2025 as RO replaced thermal plants, and that RO is projected to supply 83% of its desalinated water by 2027. Energy is 37% to 75% of operating cost. The report also says RO is approaching its thermodynamic minimum, so remaining gains from membranes and energy recovery are limited, which makes the last few percent in pumps, energy recovery and operation worth counting carefully.
High-pressure pumps, booster pumps and energy recovery
An RO plant uses a high-pressure pump to push seawater through the membranes, usually at tens of bar. An IMOA case study says most RO plants operate at very high pressure, some up to 8,000 kPa, and a design paper hosted by the Texas Water Development Board (TWDB) uses a 25 million gallon-per-day seawater plant at 63 bar as its example. The brine leaving the membranes has lost little pressure and, according to that paper, still carries almost half the energy needed for desalination, so the energy recovery device (ERD) largely determines total energy use.
- Isobaric devices (pressure exchanger types) pass brine pressure directly to the feed. The high-pressure pump then handles only a flow equal to the permeate, and a separate circulation (booster) pump makes up the 3 to 4 bar pressure difference. The paper puts recovery efficiency at about 96%, with 1.5% to 2.5% mixing and leakage.
- Turbine types (impulse turbines, turbocharger types) convert brine energy into shaft power that is passed back to the pump. The paper gives about 87% for an impulse turbine; combined with an 85% pump, only about 74 of 100 kWh in the brine returns to the feed, and the high-pressure pump has to carry the full feed flow.
For large plants the same paper argues that large pumps are about 5% more efficient than small ones, and that a few large pumps with one shared standby, instead of one pump per membrane train, raise efficiency and avoid costly standby piping. Separating the pumps from the energy recovery system also lets flow change over a wide range without frequent starts and stops, which cause demand peaks. These are the paper's engineering judgments; the right choice still depends on project size and how much production varies.
Materials: corrosion sets the life
The IMOA case study records early lessons. In some early RO plants in Saudi Arabia and Malta, 316L high-pressure fittings suffered crevice corrosion and needed replacing after as little as two years. In a 40,000 m3/day Mediterranean plant, a 6% molybdenum coupling lasted seven years against six months for a 316L one. Intermediate grades such as 317L, 904L and 2205 duplex also showed pitting and crevice corrosion. Since then 6% molybdenum stainless steel, and 2507 super duplex with similar corrosion resistance and higher strength and fatigue resistance, have become the mainstream choices on the high-pressure seawater side. The document carries no publication year, but its conclusions match current practice.
What it means for pump manufacturers: high-pressure pump selection
- Efficiency: the high-pressure pump is the biggest single electricity user in an RO plant, so compare options on weighted efficiency across the operating range rather than at one point. Large-flow pumps with few stages have a clear advantage; overlay candidate curves and duty points with performance curves.
- Variable duty: feed temperature, salinity and membrane fouling all push the required pressure up, and output changes with demand. Keep pressure and flow margins, and confirm that the lowest speed under variable frequency stays out of unstable regions. See variable-frequency pump control. Also check how the duty point moves when the system curve shifts.
- NPSH: the high-pressure pump takes its suction from intake and booster pumps, so suction pressure fluctuations and pipeline transients must be counted. See understanding NPSH and leave adequate margin.
- Materials: design seawater-wetted parts for 6% molybdenum or super duplex stainless steel, pay attention to casting quality, crevices (seals, threads, flange faces) and dissimilar-metal contact, and supply material certificates and welding procedure qualifications.
- Starts and transients: use soft starting or a ramped drive to avoid pressure shocks that damage membranes and pipework, and check full-curve non-overload and starting method for the motor.
- Matching with energy recovery: with isobaric devices the high-pressure pump flow is smaller and the booster pump supplies the pressure difference, so the two pumps must be designed as one system; with turbine types, supply a combined curve with the turbine on the same shaft. Offering both lets you meet different owners' preferences.
- Large conveyance pumps are an opportunity too: the World Bank report describes Jordan's Aqaba-Amman project, which pumps desalinated water through about 445 km of pipeline from roughly 115 m to roughly 985 m, and long-distance lift duties like this are procured alongside the plant.
References
- World Bank, Fresh Perspectives: Emerging Issues and Opportunities for Desalination in the Middle East and North Africa, 2025, documents1.worldbank.org
- Ministry of Natural Resources of China, 2024 National Seawater Utilisation Report (as reported by gov.cn from People's Daily Overseas Edition), 19 Jul 2025, gov.cn
- Texas Water Development Board, The importance of energy recovery devices in reverse osmosis desalination (technical paper), twdb.texas.gov
- International Molybdenum Association (IMOA), Molybdenum in the Water Industry: Desalination Plants (case study, no year given), imoa.info