Selection Report
The selection report combines the duty, slurry properties, selection result, configuration, performance curve, check results, bearing life and piping of one Filter Search selection into a single A4 portrait report that you can print or save as PDF in your browser. The report is opened from Filter Search step 6, from Saved Selections or from a project selection, and is shown in a new tab.
Opening the report
From Filter Search step 6
In Filter Search 6: Project options, click “Selection Report” to generate a report for the current selection. The report content is a snapshot taken at the moment you click; later changes in Filter Search do not affect a report that is already open.
From a saved selection
In the Saved Selections list, click “Report” in the row; the report is generated from the result as it was saved.
From a project selection
In Projects, select a selection and click “Report”.
When the report cannot be opened
Entries marked “Needs recalculation” (imported from a file or added from Data Search) have no complete calculation results, and the “Report” button is grayed out. Open the entry in Filter Search and save it back to the original entry first.
If you open the report address directly, or the data is no longer valid, the page shows “No report data. Open it from step 6 "Selection Report" in Filter Search.”
The report requires you to be signed in; viewing a teammate's selection report requires active team sharing.
Page toolbar
Print / Save as PDF
The button at the top right of the page opens the browser's print dialog; see Printing steps below.
Report header
Title and subtitle
Title: “Pump Selection Report”.
Subtitle: “Model · Size · Curve name”.
The browser tab title is “Pump Selection Report - Size Curve name”, which is commonly used as the default file name when saving as PDF.
Brand and Generated time
The PUMPVIZ logo and “Generated” are shown at the top right: when opened from Filter Search, this is the time you clicked “Selection Report”; when opened from Saved Selections or Projects, it is the time the selection was last saved.
Selection
Item · Content
Pump · Pump size
Curve · Curve name
Alignment · Horizontal, vertical or submersible type
Pumps · Number of pumps and arrangement, e.g. “1 (Single Stage)”, “2 (Series)”, “2 (Parallel)”
Predicted speed · Speed required at the duty point, r/min
Efficiency · Efficiency at the duty point, %
BEP efficiency · Efficiency at the curve's best efficiency point, %
Items without a value show “-”.
Duty
Item · Content
Flow · Design flow and unit; for a range duty, “Range min – max” is given in parentheses
Slurry head · Design head and unit; when the head is calculated from the piping, the calculated value is shown with “(calculated from piping)”
NPSHa · Net positive suction head available, same unit as the head
Temperature · Fluid temperature, °C
Altitude · m; 0 if not entered
Items that are 0 or not entered show “-” (except altitude); for example, a temperature of 0 °C also shows “-”.
Slurry
Item · Content
Slurry type · Water, Single Solid, Non-Newtonian, Froth, Two Solid Mix or Coal Mixture
S / Sm · Solids specific gravity / slurry specific gravity
Cw / Cv · Concentration by weight / by volume, %
d50 · Median particle size, µm
Hr / Er · Head ratio / efficiency ratio; the HR/ER method used is given in parentheses
Settling velocity · m/s
For the meaning of each parameter, see Filter Search 1: Fluid details and Filter Search 3: More options.
Performance Curve
Curve chart
The report embeds the performance curve chart of the curve, with the duty point marked for the selection duty, and carries the same watermark as the curve page.
If the curve has not been purchased, a purchase panel is shown here; after purchasing, refresh to see the curve. The rest of the report is not affected. See Curve purchases.
When printing, the curve area is kept on one page where possible.
Configuration
Lists the configuration from Filter Search step 5; empty items are not shown:
Item · Content
Impeller · Impeller part number
Impeller material · Material code - name
Liner material · Material code - description
Seal · “Gland”, “Centrifugal” or “Mechanical”; not shown for vertical and submersible pumps without a seal
Frame · Frame model and rated power, e.g. “Model (N kW)”
Bearing assembly · Bearing assembly
Shaft material · Shaft material code
Motor · Motor power in kW; r/min is appended when a motor speed has been entered
Drive · Direct or belt drive
Differential impeller · ✓ shown when a differential impeller is used
See Filter Search 5: Configuration.
Piping
Shown when piping has been entered (head set to “Calculate”), one row per pipe section:
Column · Content
Section · Sequence number
ID (mm) · Pipe inside diameter
Velocity (m/s) · Slurry velocity in this section
Settling velocity (m/s) · Settling velocity in this section
Sections where the velocity is below the settling velocity are shown with the whole row in red, warning of a risk of deposition. See Filter Search 2: Head details.
Selection Checks
Lists all check items from “Select Assist”:
Column · Content
Min / Nom / Max · Verdict at the minimum, nominal and maximum duty: ✓ pass (green), ✗ fail (red), ⚠ warning (orange); blank means not applicable
Check item · e.g. Flow (Q), NPSHa, Tip Speed, Casing Pressure, Motor Power
Comment · Explanation of the verdict
For the criteria of each item, see Select Assist (Engineering checks).
Bearing Life
Shown for horizontal pumps when bearing data is available; lists the calculation results for the candidate frames and bearing assemblies:
Column · Content
Stage · Stage number for multistage pumps
Frame, Assembly · Frame model and bearing assembly
DE L10 Life, WE L10 Life · Hours; green when acceptable, red when not
DE Stress, WE Stress, Thread Stress · Shaft stress as a percentage of the allowable value
Casing Pressure · Green when acceptable, red when exceeded
For the criteria, see Bearing Life, Critical Speed and Flange Load.
Disclaimer
Report footer
The bottom of the report states: “Generated by PUMPVIZ online selection. For selection reference only; subject to manufacturer confirmation.”
Printing and saving as PDF
Printing steps
1. Click “Print / Save as PDF”.
2. In the browser's print dialog:
To print on paper, choose a printer.
To save an electronic copy, set “Destination” to “Save as PDF” (or “Microsoft Print to PDF”).
3. Choose A4 paper, portrait orientation.
4. Tick “Background graphics” to keep table shading and colored marks.
5. Click “Save” or “Print”.
Printed output
Only the report itself is printed; the page toolbar is not.
Tables are kept from breaking across pages where possible; long content is split into multiple pages automatically.
Wait until the curve has finished loading before printing; otherwise the curve area may be blank.
Printing FAQ
Curve area is blank: wait for the curve to finish loading, or make sure the curve has been purchased.
Colors are missing: tick “Background graphics” in the print dialog.
Data is not up to date: the report is a snapshot. After changing the selection, click “Selection Report” again in Filter Search step 6; for a saved selection, open it in Filter Search, click “Save back to…” and then generate the report.