The Digital Supply Chain for Pumps: Connecting Data from Selection to After-Sales

The pump trade runs on a long chain of data: the user states the duty, the manufacturer selects, quotes, agrees a technical specification, takes the order, ships, the pump is installed, and then comes spares and repair. Most pump makers do not lack information systems; they have a separate copy of the data at each stage, linked by retyping. This article looks at how to join selection through to after-sales into one line: what product data need standardizing, how each stage can be linked, three real obstacles (data definitions, version control, price confidentiality), and a step-by-step approach.

Where the chain breaks

StageTypical outputTypical break
SelectionModel, speed, efficiency, NPSH, motorCurves sit in drawings or PDFs and selection means reading charts by eye
QuotationLine items, unit prices, discount, taxSelection results retyped into Excel; versions drift
Technical agreementDuty, materials, test requirements, guaranteesA separate Word file; values edited independently of the quote
Order and deliverySerial number, test report, documentsSerial number in ERP, test data on the test-rig PC
After-salesInstallation, repair and spare replacement recordsHandled by phone or chat; the records never return to the factory

Every break is a manual transcription, and transcription brings errors, delay and loss of traceability. The goal of connecting them is modest: enter each fact once and let other stages refer to it.

Product-data standardization: agree on the vocabulary first

For data to flow, "model, specification, material and performance point" must mean the same thing everywhere. International data standards exist, so there is no need to invent from scratch, but it helps to see what each one does:

  • IEC 61360 and ECLASS: the IEC 61360 series defines a general way to build data dictionaries; Part 4 is the IEC Common Data Dictionary (IEC CDD). ECLASS is another product-classification and property dictionary, built on the ISO 13584-42 / IEC 61360-2 data model, with globally unique identifiers for each element. According to public information, the ECLASS 15.0 BASIC release (November 2024) contains about 48,000 classes. The benefit of such dictionaries is that buyer and supplier share one definition of "rated flow", "rated head" or "casing material", in machine-readable form. No specific ECLASS pump class number could be verified, so none is given.
  • IDTA Digital Nameplate for Industrial Equipment: a submodel template for the Asset Administration Shell published by the Industrial Digital Twin Association, specifying the properties and structure of nameplate information, with semantics drawn from dictionaries such as ECLASS and IEC CDD. It is a useful structural reference for "a digital nameplate per serial number".
  • ISO 15926: a standard for integrating life-cycle data of process plants, including oil and gas facilities; Part 4 is the reference data library, and its 2010 amendment added reference data for rotating equipment. It is mainly used for plant-data handover between engineering contractors and owners. Pump makers usually meet it passively, and for most small and mid-sized makers it is not the starting point.

The practical advice: define your own fields and codes internally, keeping field names mappable to properties in those dictionaries, and map them when a large customer requires it, rather than trying to implement the full set of standards on day one.

The performance curve is the most important product data

The rated point on a data sheet is one point on a curve. Self-service selection, off-design assessment and service diagnosis need structured curves: head, efficiency, shaft power and NPSHr point lists for each speed, with revision and test basis. PUMPVIZ private models are for entering such data: from a rated-speed performance table or a multi-speed test table, it builds the speed-curve family, iso-efficiency lines and iso-NPSHr lines, and the pump is then matched by duty in search, the filter and duty simulation. Private curves are visible only to you and your team.

Selection results that generate quotes and technical agreements

The core of linking is making a "selection scheme" an object that others can reference. A scheme already holds model, specification, quantity, duty, speed, impeller material, seal and motor; quote lines can be generated from it, and the duty and guarantees in the technical agreement can take their values from it instead of retyping.

The PUMPVIZ quotation module works this way. One click generates lines from a project or saved selections: one pump line per scheme, plus a motor line if the scheme includes a motor. Unit prices come from the team price list (pumps by model and specification, motors by name, case-insensitive), and a model not in the list is flagged for manual entry. Tax, discount and totals are computed, and a Word quotation is exported. Status can be set to draft, sent, won or lost for tracking. Note that prices already in a quote do not change when the price list changes, by design, so a quote already issued cannot be rewritten after the fact.

Whether the technical agreement can be generated automatically depends on which clauses you structure. PUMPVIZ currently provides selection report and quotation export; do not treat it as a complete contract-management system.

Dealers and customers selecting for themselves

Dealers and end users often just want to see what could be selected. If that always requires a factory engineer, response is slow. The key to self-service is controlling the boundary: expose only the models you choose, give only the results the other party needs, and tier prices by identity. PUMPVIZ has three related capabilities:

  • Selection portal: the company gives customers a dedicated address with its name and logo; after registering and logging in, customers can search, filter by duty, view and export curves, generate a selection report and send an enquiry. They cannot see prices or the names of company members.
  • Dealers: the manufacturer registers dealers and sets discounts; dealer price = price-list price × (1 − discount%), and dealers see only the dealer price, never the list price. Dealers can prepare their own quotes and register projects with the manufacturer, which reviews them and protects against duplicate registration during a protection period.
  • Website embedding: put the selection widget on the company's own website; visitors enter flow and head, select from the models you open, and send an enquiry.

All three rest on the same model data, so showing one model at different prices to different audiences does not require several data sets.

Serial-number QR codes: after delivery, data keeps growing on the same chain

What is most easily lost at delivery is the link between serial number and test and installation information. The serial-number QR code feature gives each delivered pump a record and a QR code. The record holds model, specification, duty, material, linked curve and maintenance history. The code goes on the nameplate or casing; on-site staff scan it to see what the manufacturer has chosen to make public and to submit a repair request, while the manufacturer handles requests and records installation and repairs on the platform. The public scope is controllable: internal notes and the linked curve are never public, and customer name and location are not public by default. See serial-number QR codes.

Maintenance records have a second use: spare-part forecasting. The system uses only the team's own maintenance records, takes the median measured replacement interval per model and part as expected life, corrects for speed where needed (higher speed wears faster), and totals the parts needed in the next 30, 90, 180 or 365 days. With fewer than two samples it does not forecast and does not pad the result with external rules of thumb. It is better grounded than stocking "a fixed share of annual sales", provided maintenance records are filled in properly.

Connecting to your own systems

Many pump makers already run ERP, CRM, MES or mini-programs and cannot migrate everything. The PUMPVIZ selection portal offers an open interface: an API key can read quotations and project selections and read or write serial-number records. The selection endpoints are always available, while reading quotes, reading project selections and reading or writing serial-number records are authorized item by item and off by default; source IPs can be restricted. There is also event push: new enquiries, repair requests from scans, monitoring alerts, finished tests and quote status changes can be POSTed to addresses you register. These need the enterprise team edition and an active portal; details are in the documentation.

Three real obstacles

1. Data definitions

The same "rated flow" may be written in m³/h or L/s; "head" may or may not include suction losses; "efficiency" may mean pump or unit efficiency. With inconsistent definitions, the best system will still be wrong. Define unit and meaning for every field, keep a data dictionary, validate on import, and reject rather than silently convert.

2. Version control

Curves are corrected after tests, prices follow costs, models are revised. State clearly which curve version and which price-list version a quote refers to; an issued quote must not change with later edits; curve updates need a version number and effective date. Otherwise one model carries three different numbers in the selection library, the quote and the contract, and that is where disputes come from.

3. Price confidentiality

Self-service selection, dealers and interfaces all touch prices. The principle is tiering by identity: end customers in the portal see no prices, dealers see only dealer prices, internal interfaces are opened item by item and restricted by source IP. Limit who can maintain the price list. Fine-grained permissions matter more than a bigger system.

A step-by-step approach

  1. Step 1: unify the data dictionary and curves. Start with the main models; set fields, units, codes and version rules.
  2. Step 2: link price list and quotation. Build the price list by model and specification so selection results generate quote lines.
  3. Step 3: run the serial number through. Create records and QR codes, and attach test, installation and maintenance records to the serial number.
  4. Step 4: open self-service selection. Start with a few dealers or key customers, watch enquiry quality, then widen.
  5. Step 5: connect to your own systems. Read before write: start read-only on quotes and records and open write access once stable.

Keep every step reversible; do not tear up the existing process all at once in pursuit of connectivity.

Summary and checklist

  • The aim is "enter once, reference everywhere", not one more system.
  • Unify fields internally and keep them mappable to properties in dictionaries such as ECLASS and IEC 61360.
  • Structured performance curves are the shared base of self-service selection, quotation and service diagnosis.
  • Quotes, technical agreements and orders should record the curve and price versions they used.
  • Tier prices by identity; authorize interfaces item by item and restrict source IPs.
  • The serial number is the key for after-sales and spare forecasting; fill in maintenance records properly.

Related reading: Digital transformation in the pump industry.

References

  • IEC 61360 series, Standard data elements types with associated classification scheme (including the IEC CDD); ISO 13584-42 IEC 61360 overview
  • ECLASS e.V., Release 14.0 / 15.0 release information eclass.eu
  • IDTA 02006, Digital Nameplate for Industrial Equipment (v3.0 and later) industrialdigitaltwin.io
  • ISO 15926, Industrial automation systems and integration — Integration of life-cycle data for process plants including oil and gas production facilities (Part 1, 2004; ISO/TS 15926-4 reference data, including the 2010 amendment)

Loading... If the page does not appear, please make sure JavaScript is enabled in your browser.