Pump and Motor Efficiency Standards Explained: GB 19762-2025, EU MEI and IE Classes, and What They Mean for Pump Makers

Pump energy requirements are spread across three families of standards: those that rate the pump itself, those that rate the motor, and those that rate drives and drive systems, each with regional variations. This news piece maps the main schemes: the latest edition and key points of GB 19762, what MEI 0.1 and 0.4 mean in Regulation (EU) No 547/2012, how motor IE classes relate to GB 18613, and what it all means for pump makers' R&D and selection. Edition numbers, implementation details and values that could not be verified against a source are left out.

First, who rates what

ObjectStandard or regulationMetric
Centrifugal pumps (China)GB 19762-2025Efficiency at the specified point compared with grade requirements; grades 1, 2, 3
Water pumps (EU)Commission Regulation (EU) No 547/2012Minimum Efficiency Index MEI, at BEP, 75% and 110% flow
Clean water pumps (US)10 CFR Part 431 (DOE)Pump Energy Index PEI
MotorsIEC 60034-30-1; GB 18613-2020; (EU) 2019/1781IE classes; grades 1, 2, 3 in China
Drives and drive systemsIEC 61800-9-2 (formerly EN 50598-2)Drive IE class, drive system IES class

The scopes of these metrics differ: GB 19762 and MEI rate only the hydraulic efficiency of the pump, while motor efficiency and drive losses are counted separately. Actual electricity use of a pump set is set jointly by pump, motor, drive and piping system.

GB 19762: from the 2007 edition to 2025

The early GB 19762-2007 was titled "Minimum allowable values of energy efficiency and evaluating values of energy conservation of clean water centrifugal pumps". GB 19762-2025, "Minimum allowable values of energy efficiency and energy efficiency grades for centrifugal pumps", was issued on 28 February 2025 and takes effect on 1 March 2026. It is a mandatory national standard that replaces GB 19762-2007 and GB 32284-2015 (energy efficiency of petrochemical centrifugal pumps), combining clean-water and petrochemical pumps in one standard.

Points that public sources allow us to confirm:

  • Scope: single-stage single-suction, single-stage double-suction, in-line, multistage and light multistage clean-water centrifugal pumps, and petrochemical centrifugal pumps handling clean liquids with closed impellers. Non-metallic centrifugal pumps and sealless rotodynamic pumps are excluded. Slurry pumps are not in the listed scope.
  • Grades: grades 1, 2 and 3. Grade 3 is the minimum allowable value, the lowest requirement for putting a product on the market; grade 1 is the highest efficiency. The old "evaluating value of energy conservation" wording has been dropped.
  • Specified point: grades are determined at the best-efficiency point at full (maximum) impeller diameter and design base speed, using that point's flow and head to set the requirement.
  • Calculation: the linear interpolation of the old edition is replaced by functions of specific speed, specified per pump type, with constants separating the grades.

Two clarifications. First, the standard does not use the name MEI: in the sources I found, it compares the pump's efficiency at the specified point with the requirement for each grade, so equating it with the EU's MEI is a common misreading. Second, the equations, constants and limits for each pump type, and whether there is a transition period between old and new editions, could not be verified against a reliable source and are not repeated here; rely on the standard text and official implementation arrangements.

Regulation (EU) No 547/2012 and MEI

Issued on 25 June 2012 under the Ecodesign Directive 2009/125/EC, the regulation sets minimum efficiency for water pumps. The designs covered are end suction own bearing (ESOB), end suction close coupled (ESCC), end suction close coupled inline (ESCCi), vertical multistage (MS-V) and submersible multistage (MSS).

  • Definition of MEI: a dimensionless minimum efficiency index covering hydraulic efficiency at the best efficiency point (BEP), part load (PL, 75% of BEP flow) and overload (OL, 110% of BEP flow). It is based on the full impeller diameter, measured on clean cold water; each pump type and speed has its own C value from which the minimum efficiency for a given MEI follows. Testing and calculation are covered by EN 16480.
  • 0.1 and 0.4: from 1 January 2013 pumps must reach MEI ≥ 0.10, and from 1 January 2015 MEI ≥ 0.40. All three points must comply, with the PL and OL requirements set slightly lower than at BEP.
  • What the numbers mean: MEI is calibrated on the market distribution of pump efficiency. Several studies read 0.1 and 0.4 as roughly removing the least efficient 10% and 40% of products on the market. The regulation also gives a benchmark: the most efficient water pumps have MEI of at least 0.70.
  • Impeller: MEI is judged on the full impeller diameter; pumps supplied with trimmed impellers are not covered.

GB 19762-2025 and MEI side by side

ItemGB 19762-2025(EU) No 547/2012
Evaluation pointsSpecified point (best-efficiency point at full impeller and base speed)Three flow points: BEP, 75%, 110%
Threshold formGrades 1, 2, 3; grade 3 is the market-access minimumMEI ≥ 0.40 (0.1 was the 2013 step, 0.7 is the benchmark)
Pumps coveredClean-water and petrochemical pumps of several constructionsFive specified clean-water designs
ImpellerFull impeller diameterFull impeller diameter

The United States uses PEI instead: 10 CFR Part 431 expresses its standard for five classes of clean water pumps (each at two speeds) as a Pump Energy Index, the ratio of a pump's energy rating to that of a minimally compliant pump, with values above 1.00 not compliant. It has applied since 27 January 2020, and sewage and other solids-handling pumps are outside it.

Motors: IE classes and GB 18613

  • IEC 60034-30-1: defines efficiency classes for line-operated motors. The first edition (2014) covers single-speed motors of 0.12-1000 kW, defines IE1 to IE4 and added 8-pole machines; the second edition, published in 2025, adds IE5.
  • GB 18613-2020: "Minimum allowable values of energy efficiency and energy efficiency grades for electric motors", issued 29 May 2020 and in force from 1 June 2021, replacing GB 18613-2012 and GB 25958-2010. It has grades 1, 2 and 3, with grade 3 the minimum allowable value. Public sources generally state that grades 1, 2 and 3 correspond roughly to IE5, IE4 and IE3, whereas those of the 2012 edition corresponded to IE4, IE3 and IE2, so the entry threshold rose from IE2 to IE3. Use the standard text for the actual limit tables.
  • (EU) 2019/1781: from 1 July 2021, three-phase motors of 0.75-1000 kW must reach IE3; from 1 July 2023, 2-, 4- and 6-pole induction motors of 75-200 kW must reach IE4. The regulation also requires drives to reach IE2 but does not make using a drive mandatory.

A simple estimate shows the scale of motor efficiency differences (assumed example): two 22 kW motors with full-load efficiency of 91.6% and 93.0% draw about 24.02 kW and 23.66 kW, a difference of about 0.36 kW, or about 2170 kWh a year at 6000 h. The gain looks small, but on larger pump sets running for long hours it accumulates.

What this means for pump makers' R&D and selection

  • The specified point sets the design target: GB 19762-2025 rates at the best-efficiency point at full impeller and base speed, so hydraulic design should aim to reach the target grade at that point; trimming the impeller or lowering speed to "game" it no longer works, and the BEP data in catalogues and test reports must match the definition of the specified point.
  • Specific speed is the main variable: low specific speed pumps are naturally less efficient, and the new standard's requirements vary with specific speed. Map the efficiency of each series against specific speed first and find the range with the largest gap to the target grade.
  • For export, look at the three MEI points: for EU products the 75% and 110% flow points must comply as well as BEP, so curve flatness matters as much as single-point efficiency.
  • Match motors at IE3 or better: the entry threshold in GB 18613-2020 is already IE3 level, and a high-efficiency pump with a low-efficiency motor cancels the hydraulic gain. With a drive, include drive losses; see VFD Pump Control.
  • Standards rate the best point; savings come from the operating point: however high the grade, selection away from BEP or generous system margins still wastes energy. Check %BEP and the system curve during selection; see Reading Pump Curves.
  • Tenders and technical files: state the pump's efficiency grade or MEI and the basis of evaluation in quotations and technical responses, and separate the pump from the set.

PUMPVIZ Efficiency Rating takes the flow, head, speed and efficiency at the best-efficiency point and returns grade 1, 2 or 3 under GB 19762-2025, or "below grade 3", and can also calculate MEI under EU 547/2012 and check MEI ≥ 0.40; Motor Selection and Analysis compares the annual electricity cost of IE2, IE3 and IE4 motors. The results are for design and selection reference only; registration of efficiency labels and certification rest on tests by a qualified laboratory to the standard.

Summary and checklist

  • The current Chinese pump efficiency standard is GB 19762-2025, in force from 1 March 2026, replacing the 2007 edition and GB 32284-2015; it uses grades 1, 2, 3 with grade 3 as the market-access level.
  • It rates efficiency at a specified point and is not called MEI; the EU's MEI covers BEP, 75% and 110% flow, with 0.1 and 0.4 the thresholds from 2013 and 2015.
  • The current motor standard is GB 18613-2020 with an IE3-level entry threshold; internationally, edition 2 of IEC 60034-30-1 adds IE5.
  • In R&D, map each series' efficiency against the specified point and specific speed; for export, watch three-point efficiency and curve flatness.
  • In selection, check BEP, %BEP and the system curve, and specify motors at IE3 or better.
  • For limit values by pump type, transition periods and certification rules, rely on the standard text and official documents.

References

  • GB 19762-2025, Minimum allowable values of energy efficiency and energy efficiency grades for centrifugal pumps, SAMR and SAC, issued 2025-02-28, effective 2026-03-01 (national standards open platform)
  • Commission Regulation (EU) No 547/2012 of 25 June 2012 implementing Directive 2009/125/EC with regard to ecodesign requirements for water pumps (EUR-Lex)
  • EN 16480, Pumps - Minimum required efficiency of rotodynamic water pumps
  • 10 CFR 431.465, Pumps energy conservation standards and their compliance dates (eCFR)
  • IEC 60034-30-1, Efficiency classes of line operated AC motors (IE code), edition 1 (2014) and edition 2 (2025)
  • GB 18613-2020, Minimum allowable values of energy efficiency and energy efficiency grades for electric motors (national public service platform for standards)
  • Commission Regulation (EU) 2019/1781, ecodesign requirements for electric motors and variable speed drives (European Commission)
  • IEC 61800-9-2, Ecodesign for power drive systems, motor starters, power electronics and their driven applications - Energy efficiency indicators for power drive systems and motor starters