HR/ER Derating in Slurry Pump Selection: Definitions, Drivers and the Calculation from Head to Shaft Power

The performance curves in a slurry pump catalogue are measured on clear water, but the duty is a mixture with solids: at the same flow and speed the pump develops less head and runs at lower efficiency. Without correction, the result is a flow shortfall at best and an undersized motor at worst. This article explains HR (head ratio) and ER (efficiency ratio), what drives them, the calculation sequence from system head to shaft power, a reproducible example showing how much is lost by ignoring them, and the usual mistakes.

Definitions of HR and ER

  • Head ratio HR = head on slurry / head on clear water, compared at the same flow and the same speed.
  • Efficiency ratio ER = efficiency on slurry / efficiency on clear water, also at the same flow and speed.
  • In the literature 1 - HR is often called the head reduction factor and 1 - ER the efficiency reduction factor.

Both ratios are normally at or below 1 (user-entered test values aside); the smaller, the larger the derating. Solids change the flow inside the impeller, and particle-wall and particle-particle interactions consume energy, so less useful energy reaches the mixture.

How ER relates to HR depends on concentration. Work by Sellgren and co-authors reports that up to a volumetric concentration of roughly 20%-25% the efficiency reduction is about equal to the head reduction, and several technical handbooks state that ER is not greater than HR because it also reflects power losses. At modest concentration, ER ≈ HR is a fair approximation; at high concentration ER is often lower and should not simply copy HR.

What sets the size of the derating

FactorDirectionNotes
Particle size d50 relative to impeller diameterLarger d50 and smaller impeller mean more deratingd50/D is a common correlating parameter; for narrowly graded sands and gravels, derating was found to decrease as pump size increases
Volumetric concentration CvHigher concentration, more deratingAbove roughly 20%-25% the efficiency drop becomes more marked than the head drop
Solids specific gravity SHigher S, more deratingHI charts take S = 2.65 as the base; other values get a correction factor
Fine-particle content (-75 μm)More fines, less deratingFines thicken the carrier liquid and help suspend coarse particles
Slurry typeSettling, froth and non-Newtonian slurries behave differentlyFroth depends on air content and paste-like slurries on yield stress; applying settling-slurry charts is optimistic

Technical handbooks describe the HI 12.1-12.6 approach as follows: base curves correspond to Cv = 15%, solids SG 2.65 and negligible fines, with separate correction factors for specific gravity, fines and concentration applied for other conditions. Exact values and curves are in the standard itself, and this article does not reproduce empirical coefficients that have not been checked against it.

What ANSI/HI 12.1-12.6 covers

The standard is titled "Rotodynamic (Centrifugal) Slurry Pumps for Nomenclature, Definitions, Applications and Operation", published by the Hydraulic Institute (HI), and its scope is limited to single-stage, overhung-impeller horizontal and vertical industrial pumps for abrasive slurries. The publisher's description divides the content into types and nomenclature, definitions, design and application, installation, operation and maintenance, and testing guidelines; HR/ER derating belongs to design and application. Two cautions when using it:

  • Edition: the 2016 edition (approved August 2016) has been superseded by the 2021 edition. Use the edition named in the contract.
  • Scope: it is limited to single-stage overhung impellers, so other constructions such as multistage pumps are outside it and applying its charts to them can mislead.

Check the exact part titles and clause numbers against the text of the edition you hold rather than quoting them from older notes or secondary sources.

From system head to shaft power: the sequence

  1. Slurry properties: solids SG S, carrier SG Sw, volumetric concentration Cv. Mixture SG Sm = Sw + Cv(S - Sw), weight concentration Cw = CvS / Sm. For example S = 2.65, Sw = 1, Cv = 14% gives Sm ≈ 1.23 and Cw ≈ 30%.
  2. Slurry head Hm: static head + friction loss + velocity head + terminal pressure, expressed as a column of slurry. Friction must be calculated for the slurry, not for water.
  3. Choose HR and ER by slurry type and whether a pump has been selected.
  4. Water-equivalent head: Hw = Hm / HR. Use Q and Hw to find the speed and impeller on the clear-water curve.
  5. Slurry efficiency: ηs = ηw × ER, with ηw read at the same point of the clear-water curve.
  6. Shaft power: P (kW) = 9.81 × Q (L/s) × Hm (m) × Sm / (1000 × ηs). When HR = ER this equals the clear-water shaft power at the same flow and speed multiplied by Sm, which gives a quick cross-check.
  7. Motor: add the service factor and check the maximum power along the whole curve, since power can exceed the duty-point value when flow shifts. See Motor Selection and Analysis.
  8. Other checks: pipe velocity against settling velocity, tip speed, NPSHa and so on. NPSHa is expressed in slurry column; see Understanding NPSH for the conversion.

Worked example (assumed data, reproducible)

Take Q = 50 L/s, slurry head Hm = 28.1 m, Sm = 1.23, HR = ER = 0.90, and clear-water efficiency ηw = 70% at that point.

  • Water-equivalent head Hw = 28.1 / 0.90 ≈ 31.2 m; find the speed on the clear-water curve at 31.2 m.
  • Slurry efficiency ηs = 0.70 × 0.90 = 63%.
  • Shaft power P = 9.81 × 50 × 28.1 × 1.23 / (1000 × 0.63) ≈ 26.9 kW. Check: clear-water shaft power at that point = 9.81 × 50 × 31.2 / (1000 × 0.70) ≈ 21.9 kW; times Sm = 1.23 gives 26.9 kW, which agrees.

If HR and ER are ignored and the speed is read for 28.1 m on the clear-water curve, the real slurry head is only about 25.3 m, a 10% shortfall. Recovering it takes about 5.4% more speed (affinity law, H proportional to n2, so (1/0.9)0.5 ≈ 1.054), which raises power by about 17% ((1.054)3). Ignoring ER alone underestimates shaft power by about 11%, which feeds straight into motor selection.

Common mistakes

  • Correcting head but not efficiency: shaft power is still computed from clear-water efficiency and the motor is undersized.
  • Entering HR as a percentage: typing 90 instead of 0.90 in a user-defined value.
  • Leaving slurry data at defaults: a tiny d50 and zero concentration make HR equal 1 and the result optimistic.
  • Mixing Cw and Cv: they differ a lot (30% against 14% above); know which one the method needs.
  • Using settling-slurry methods for paste or froth: the mechanisms differ; pick the matching method.
  • Friction calculated for water: Hm is underestimated and every later correction rests on a low head.
  • Ignoring the edition: when a specification calls for the ANSI/HI method, different editions may give different results.
  • Applying single-stage overhung charts to multistage pumps: outside the standard's scope.

How PUMPVIZ handles it

PUMPVIZ Filter Search includes 8 HR/ER methods and runs 15 engineering checks alongside (those relevant here include flow, Sm/Sw/Cw/Cv, water and slurry head, suction and discharge pipe velocity, tip speed and motor power). The methods group by their inputs:

Method typeMain inputsStage of use
Empirical method based on slurry properties only (default)d50, S, CwEarly screening before a pump is chosen; ER equals HR
Pump-based method that includes impeller sizeVane diameter, d50, S, CvOnce a curve is selected; ER is reduced further above Cv of 20%
Combined standard method (default once a curve is selected)Vane diameter, d50, S, Cv, fines contentConventional mineral slurry; recommended first
ANSI/HI 12.1-12.6Same as aboveWhen the specification requires it; ER is an estimate
FrothFroth volume factor FVFFlotation froth and other aerated slurries
Non-NewtonianSlump plate readingPaste and thickened tailings
Coal industryPreset pump-function rowsCoal preparation duties
User-definedHR, ER (minimum 0.01)When you have your own test data

The software divides the slurry head by HR to get the clear-water head for the speed search, then corrects efficiency with ER for power; once a curve is selected, HR/ER update when the impeller diameter changes. These are engineering estimates, and the final word rests with data confirmed by the manufacturer and the standard named in the contract. For the wear side of slurry duty, see Slurry Pump Wear and Wet-End Material Selection.

Summary and checklist

  • HR and ER are the ratios of slurry to clear-water performance at the same flow and speed, and both head and power need them.
  • d50 relative to impeller diameter, concentration, solids SG and fines content dominate; ER ≈ HR at modest concentration, with ER lower at high concentration.
  • Sequence: slurry properties, slurry head, HR/ER, water-equivalent head, speed and efficiency, shaft power, motor and other checks.
  • Cross-check with the HR = ER relation: slurry shaft power ≈ Sm × clear-water shaft power.
  • Do not apply settling-slurry charts to paste or froth, and verify the ANSI/HI edition and scope.
  • Without reliable d50 and concentration, stay conservative and ask the manufacturer for the derating basis for that pump.

References

  • ANSI/HI 12.1-12.6, Rotodynamic (Centrifugal) Slurry Pumps for Nomenclature, Definitions, Applications and Operation, Hydraulic Institute, 2016 and 2021 editions (pumps.org)
  • Wilson K.C., Addie G.R., Sellgren A., Clift R., Slurry Transport Using Centrifugal Pumps, Springer
  • Sellgren A., Centrifugal pump performance derating for coarse particle and highly concentrated settling slurries (PDF)
  • AusIMM Minerals Processing Toolbox, Slurry Pumping Introduction (PDF)

Loading... If the page does not appear, please make sure JavaScript is enabled in your browser.