This chapter describes the pump performance curve page: what the lines, points and colors on the chart mean, the specification table on the right, pressing and dragging to read values, duty points and notes, the context menu, zooming, printing and export (SVG, PNG image and curve points CSV), and the purchase panel shown for unpurchased curves. The curve page is opened from Data Search, Filter Search, Private models and other places.

Opening the curve page

Opening from Data Search

In the Data Search result table, double-click a row, or right-click it and choose “View”, to open a separate curve report window. If you entered a duty (flow, head) for the search, a primary duty point named DP01 is placed at that duty automatically when the window opens; if you entered NPSHa for the search, the readout box also shows the NPSHa.

Opening from Filter Search

In step “4 Curve Selection”, double-click a curve row or right-click it to view the curve: the report window opens and duty points are marked automatically from the complete Filter Search duty (single/multiple pumps, duty ranges, froth slurry and so on are each marked differently; see Duty point readout box).

The right side of step “5 Configuration” is an embedded preview of the curve; choose “Full Screen” or “Multi Stage Curve” in the drop-down list of the bottom bar and click “View” to open it in a report window.

For details see Filter Search 4: Curve selection and Filter Search 5: Configuration.

Other entry points

“View curve” in the Private models list.

The “Curve” button of saved selections in Saved Selections and Projects, which marks the duty again as it was when saved.

Curve names in the “Favorites” list of Filter Search step 6: they open as a standard curve page in a new tab.

The “Recently viewed” list shown in Data Search before you search.

“My Account” → “Purchases & history” → “Purchased curves” list; see Top-up and account.

Page layout

Curve report window

A separate window opened from the various entry points; its layout matches the printed page:

Top menu bar: “File”, “Edit”, “Zoom”; see Report window menus.

Top of the left column: the disclaimer box (collapsed to one line by default; can be expanded, see Disclaimer), with the pump type title (installation/pump type + Pump) and the large model name to its right.

Body of the left column: the curve chart.

Right column: the PUMPVIZ logo and the specification table; at the bottom, in order, the copyright line, the gray “TYPICAL PUMP PERFORMANCE CURVE” bar and the black “Curve name/1” model box.

The window title is “Curve name, pump model”.

The window size you set by dragging is remembered and reused the next time you open a curve window from Data Search (stored in the current browser).

Standard curve page

When the curve is not opened as a window, the top of the page shows the curve name and pump model, followed by tags:

Rated speed n r/min: the rated (maximum) speed of a speed curve family; not shown for impeller diameter curve families.

Public manufacturer curves: the data comes from material published on the manufacturer's website; the “Data source” link next to it leads to the original page.

Partly estimated: one section of the curve was estimated to fill in missing data; hover the mouse to see an explanation, which is also given in orange text below.

Below the chart there is a line of legend text.

Embedded preview in Filter Search

The small chart on the right of Filter Search step 5 shows only the curve, without the specification table and copyright bar. In it only “View”, “Zoom” and “Copy to” are available in the context menu; the other items are grayed out, and double-clicking does not create a duty point.

Lines and markers on the chart

Axes and grid

Horizontal axis: flow in m³/h (axis label “Flow m³/h”).

Vertical axis: head in m (the vertical axis has no label).

The scale is rounded automatically from the maximum values of the curve data; thick gray lines mark the major divisions. Each major division is split into 10 minor divisions in the flow direction and 5 in the head direction, so values can be read directly.

The curve page always uses m³/h and m, regardless of the units chosen for the search.

Speed curves

Thin solid black lines, one per speed, with the speed value labeled at the left end (e.g. 1200 rpm). All speed lines have the same width and are distinguished by their left-end labels. The speed curve family can be hidden or shown with “View > Speed CurveSet” in the context menu.

Impeller diameter curves

Some curves are organized by impeller diameter instead of speed (same speed, different trimmed diameters). Each line of such a curve is labeled with its diameter at the left end (e.g. 365.5 mm); the info window and readout box show “Diameter” instead of “Speed”, and no rated speed tag is shown at the top of the page.

Iso-efficiency lines

Thin solid black lines joining points of equal efficiency, labeled with a percentage at the higher-head end (e.g. 72%). If an efficiency line folds back into an island and its other end is clearly lower than its start, the other end is labeled with the same percentage too. The slanted word “EFFICIENCY” is drawn along the direction of the iso-efficiency lines.

Best efficiency line (BEP)

The iso-efficiency line with the highest value is drawn in red, with a red label, marking the region of the best efficiency point (Best Efficiency Point, BEP).

NPSHr lines

Dashed blue, nearly vertical lines joining points of equal net positive suction head required (Net Positive Suction Head Required, NPSHr), labeled with the value at the bottom end (e.g. 3m, 4.5m). The slanted word “NPSHr” appears on the chart.

Duty point marker

A right-angle arrow marker whose tip is the position of the duty point:

Red: primary duty.

Green: other duty points.

Readout box

A white text box next to the duty point marker, with a border in the same color as the marker, listing the readings at that point; for the meaning of each line see Duty point readout box. If you clear “Create Note” when creating a duty point, no readout box is shown.

Note markers

A small orange square with a light yellow text box, used to write explanatory text on the chart; see Note dialog.

System Resistance Curve

A thick magenta line showing the head required by the piping system at different flows. It exists only when the curve was opened from Filter Search and piping was entered in the duty; it is hidden by default and can be turned on with “View > System Resistance Curve” in the context menu.

Stage curves (Water / Slurry)

Shown together with the system resistance curve: pump curves generated at the speed required by the duty point. The blue lines are the water curves (one more line for each additional pump when there are several pumps), and the last, green line is the slurry curve (water head × Hr); the chart labels the speed value and the words “Water” and “Slurry”.

Settling velocity flow line

A short blue vertical line at the bottom of the chart, labeled vertically “Settling Velocity at Flow X m³/hr”: the flow at which the velocity in the discharge pipe equals the settling velocity. Below this operating flow, solid particles may settle in the pipe. Available only when the curve was opened from Filter Search with piping; shown by default when head is calculated from piping, and can be switched on and off with “View > Settling Velocity” in the context menu.

Laminar flow line

A thick dashed purple horizontal line labeled “Laminar Flow”. It appears only for non-Newtonian slurry duties: the flow at the right end of the line is the laminar/turbulent transition flow calculated from the smallest diameter of the suction and discharge pipes, and its vertical position is the system head at that flow. Below this operating flow, flow in the pipe is laminar.

Critical speed

When a bearing assembly and shaft depth have been selected for a vertical pump in Filter Search, graded colored regions appear in the chart background, dividing the speed range by the critical speeds of the shaft:

Region color · Speed range

Green · Minimum speed to first critical speed (corrected)

Red · First critical speed to second critical speed

Green · Second critical speed to third critical speed

Any boundary above the highest speed of the curve is cut off at the highest speed. Avoid duty points that fall in the red region. For the critical speed calculation see Bearing Life, Critical Speed and Flange Load.

Multi-stage curve view

When you choose “Multi Stage Curve” in the drop-down list at the bottom of Filter Search step 5 and click “View”, and the duty involves multiple pumps, single solid slurry or water, the chart draws only:

Blue water stage curves, labeled “1 H (n rpm)”, “2 H (n rpm)” and so on, showing the combined head of 1 pump, 2 pumps and so on; the speed in brackets is the speed of the water stage curve;

Green slurry stage curves, labeled “1 H”, “2 H” and so on;

The magenta system resistance curve, when piping was entered.

The upper limit of the vertical axis is head per pump × number of pumps × 1.2.

Specification table

The table to the right of the curve lists the structural parameters of the pump the curve belongs to; items without data show “-”. Private curves and public manufacturer curves usually have no such data.

Suction

Suction diameter in mm, rounded to an integer.

Discharge

Discharge diameter in mm, rounded to an integer.

Vanes

Number of impeller vanes.

Impeller diameter

Outside diameter of the impeller vanes, mm (shown as “Vane ø”).

Type

Impeller type.

Part No and Material

Two columns, “Part No” and “Material”, one row per available impeller part number and its material; one curve can correspond to several impeller part numbers.

Frame (Rating - KW)

One row per available frame: on the left the frame model, on the right the rated power of that frame (kW).

Seal

Seal type, shown as “Type Sealed Pump”.

Liner (Norm Max r/min)

One row per liner: on the left the liner material, on the right the maximum speed allowed for that liner (r/min). The selected speed should not exceed the value allowed for the chosen liner.

Min Passage Size

Smallest passage size inside the pump, mm; it determines the largest particle that can pass.

Press and drag to read values (info window)

Press and hold the left mouse button in the curve area to bring up the “INFOWINDOW”, which shows the interpolated readings at that point; while you drag, the info window follows the cursor and updates in real time, and it disappears when you release the button. Near the edge of the chart, the info window flips to the other side of the cursor automatically. If the point lies outside the curve range, only flow and head are shown.

For Water Only

The note in the first line of the info window: all readings are calculated for water, without slurry SG, Hr/Er or seal derating.

Flow (info window)

Flow at the cursor position, m³/hr, one decimal place.

Head (info window)

Head at the cursor position, m, one decimal place.

Speed (info window)

Speed the pump needs to pass through this point, r/min, interpolated from the adjacent speed curves.

Impeller Diameter (info window)

Shown only for impeller diameter curve families: impeller diameter needed to pass through this point, mm.

Efficiency (info window)

Pump efficiency at this point, %, interpolated from the iso-efficiency lines.

NPSHr (info window)

NPSHr at this point, m, interpolated from the NPSHr lines.

Power (info window)

Water shaft power at this point, kW:

P (kW) = 9.81 × Q (L/s) × H (m) ÷ (η (%) × 10)

Example (hypothetical numbers): Q = 360 m³/h = 100 L/s, H = 30 m, η = 70%, P = 9.81 × 100 × 30 ÷ 700 ≈ 42.0 kW.

Duty Point

Duty points are kept only in the current window and disappear when the window is closed or refreshed; to keep them, use “Annotations > Save...” in the context menu.

Double-click to create a duty point

Double-click in the curve area to open the “Create Duty Point” dialog with the flow and head of the double-clicked position. This is the same as right-clicking there and choosing “Duty Point > Add...”.

Dragging the duty point

Press the left button near a duty point marker (within about 16 pixels) and drag to move the duty point; the speed, efficiency, NPSHr, power and other values in the readout box update in real time with the position.

Dragging the readout box

Press the left button inside a readout box and drag to move it to a position where it does not cover the curve; the readout box keeps its position relative to the marker and moves with the duty point.

By default the readout box is placed to the lower right of the marker; when the duty point is near the bottom or right edge of the plot area and there is no room, it is automatically placed above or to the left of the marker. A readout box you have dragged keeps the position you dragged it to.

Duty point readout box

The lines of the readout box are arranged in the following order; lines without a value are not shown.

Duty Name (readout box)

The first line: the name of the duty point. Points marked automatically from Filter Search may be named “New Duty”, “Design”, “Min”, “Max”, “Aerated”, “Non-aearated” and so on.

Flow (readout box)

Duty flow, m³/hr.

H(SL)

Slurry head per pump, m.

H(W)

Water head per pump, m, equal to slurry head ÷ Hr. Points added manually on the curve page are treated as water, so both lines show the same value.

Speed (readout box)

Speed required to pass through the point, r/min. When a differential impeller is selected in Filter Search, it is shown as curve speed × 1.18 with the “(Diff)” mark.

Impeller Diameter (readout box)

Shown only for impeller diameter curve families, mm.

Efficiency (readout box)

Pump efficiency, %. The suffix “(Exp)” means the efficiency loss of a centrifugal seal (expeller) has been deducted; the suffix “(MS)” means the efficiency loss of a mechanical seal has been deducted.

NPSHr (readout box)

NPSHr at this point, m.

NPSHa (readout box)

NPSHa provided by the installation, m. Shown only when NPSHa was given in the duty, or when “Show NPSHa” is ticked in the dialog and a value entered.

Power (readout box)

Shaft power, kW; the suffixes mean the same as for efficiency. Points marked from Filter Search are calculated for slurry:

P (kW) = Sm × Q (L/s) × H_slurry (m) × 0.981 ÷ (η (%) × Er)

Here η already includes the seal derating. Points added manually on the curve page are calculated for water (Sm = 1, Er = 1).

Slurry SG (readout box)

Slurry SG Sm. 1.00 for manually added points. For froth slurry duties this line is shown as “Sf”, with the value Sm ÷ froth volume factor.

Q BEP(%)

Duty flow as a percentage of the best efficiency point flow (%BEP). The duty point is first converted along the affinity parabola to the rated speed and then compared with the BEP flow at rated speed:

%BEP = Q ÷ ( Q_BEP × √(H ÷ H_BEP) ) × 100

Q_BEP and H_BEP are the best efficiency point at the rated speed of the curve. Example (hypothetical numbers): Q_BEP = 100 L/s, H_BEP = 40 m, duty Q = 90 L/s, H = 36.7 m, √(36.7/40) ≈ 0.958, %BEP = 90 ÷ 95.8 × 100 ≈ 94%.

Tip: Points marked automatically from Filter Search show the results Filter Search calculated from the complete duty; once you drag such a duty point, its readings are interpolated in real time at the new position and calculated for water.

Duty point dialog

The “Create Duty Point <name>” and “Edit Duty Point <name>” dialogs have inputs on the left and the surface values panel on the right.

Duty Name

Name of the duty point; new points are numbered DP01, DP02 … DP09, DP10 … by default (two digits, padded with 0).

Flow (dialog)

Flow of the duty point, m³/h. For a new point, this is the flow at the double-clicked or right-clicked position.

Head (dialog)

Head of the duty point, m.

NPSHa (dialog)

NPSHa of the installation, m. Can be entered only after ticking “Show NPSHa”; once entered, it is shown in the readout box. It is a label only and is not used in calculations.

Primary Duty

When ticked, the point is shown with a red marker and the primary duty flag is removed from all other points; a curve has only one primary duty. The first (or only) duty point must be the primary duty; in that case this option is ticked automatically and cannot be changed.

Create Note

When ticked, a readout box is shown next to the duty point. Available only when creating a point; cannot be changed when editing.

Add curve at this speed

Always grayed out; not yet available in the web edition.

Show NPSHa

When ticked, you can enter “NPSHa” and it is shown in the readout box; when cleared, it is not shown.

Surface Values

The panel on the right, updated in real time with the flow and head you enter, shows the interpolated results for that point on the curve:

Item · Meaning

Speed · Speed required to pass through the point, r/min; -1 if the point is outside the curve range

Eff · %

NPSHr · NPSHr, m

P · Water shaft power, kW; shows ∞ when there is no efficiency data

Sm · Fixed at 1.00

OK and Cancel

Click “OK” to save; if the flow or head is not greater than 0, the dialog simply closes without saving. Click “Cancel” to discard the changes. If you change the flow or head while editing, the readings are recalculated at the new position.

Note dialog

The “Add Note” and “Edit Note” dialogs place explanatory text on the chart.

Text (note)

Content of the note; multiple lines are allowed. If the text is empty, clicking “OK” does not save.

Note position

Two input boxes, “Flow” (m³/h) and “Head” (m), giving the coordinates of the note square on the chart. A new note takes the right-clicked position; you can change the values manually for exact placement. Notes cannot be dragged with the mouse; to move one, edit its coordinates.

Context menu

Right-click in the curve area to open the menu. Items that act on an existing object, such as “Edit”, “Delete” and “Copy”, are available only when you right-click near a duty point marker or note square (within about 16 pixels).

Duty Points > Add...

Opens the “Create Duty Point” dialog with the flow and head of the right-clicked position; see Duty point dialog.

Duty Points > Edit...

Opens the “Edit Duty Point” dialog for the clicked duty point.

Duty Points > Delete

Deletes the clicked duty point.

Duty Points > Duplicate

Copies the duty point at the same position, named “original name copy”; the copy is not the primary duty. After copying, the two points overlap; drag them apart.

Duty Points > List Duty Points...

Opens the “Duty Points” list showing name, flow, head and efficiency, with “Edit”, “Copy” and “Del” buttons on each row. When there are no duty points it shows “None yet — right-click the chart to add”.

Notes > Add...

Opens the “Add Note” dialog with the right-clicked position as coordinates.

Notes > Edit...

Edits the clicked note.

Notes > Delete

Deletes the clicked note.

Notes > List Notes...

Opens the “Notes” list showing text, flow and head, with “Edit” and “Del” buttons on each row.

Annotations > Load...

Choose a previously saved annotation file (.json) to load all duty points and notes in it, replacing the annotations currently on the chart. If the file is not valid, “Invalid file” is shown; on success, “Annotations loaded”.

Annotations > Save...

Downloads all current duty points and notes as a file named “Curve name.annot.json” and shows “Annotations saved”. Next time you open the same curve, restore them with “Load...”.

Annotations > Clear All

Removes all duty points and notes from the chart and shows “Annotations cleared”.

View > Speed CurveSet

Ticks/clears the display of the speed curves (for impeller diameter curve families, the diameter curves). The menu stays open after clicking, so you can toggle several items in a row.

View > Efficiency CurveSet

Ticks/clears the display of the iso-efficiency lines, their percentage labels and the word “EFFICIENCY”.

View > NPSHr CurveSet

Ticks/clears the display of the NPSHr lines, their labels and the word “NPSHr”.

View > Expeller CurveSet and Power CurveSet

Grayed out when the curve has no such data; when it has data, the item is shown ticked but cannot be toggled, and clicking it shows “"Expeller CurveSet" is coming soon” (or “"Power CurveSet" is coming soon”).

View > System Resistance Curve

Ticks/clears the display of the system resistance curve and the stage curves. Available only when the curve was opened from Filter Search and the duty includes piping; otherwise grayed out.

View > Settling Velocity

Ticks/clears the display of the settling velocity flow line. Available under the same conditions as above.

Zoom (context menu)

Submenu 100% (Ctrl + 1), 200% (Ctrl + 2), 300% (Ctrl + 3), 400% (Ctrl + 4), which enlarges the chart to the corresponding factor. After zooming, scroll bars appear in the chart area so you can scroll around. For other methods see Zoom shortcuts.

Print...

Prints the curve. In the report window the whole report is printed (see Printed output); on the standard curve page the current page is printed.

Print Preview...

Same as “Print...”: opens the browser's print dialog, where you can preview, choose a printer or save as PDF.

Copy to > Clipboard

Copies the chart to the clipboard as a PNG image at 2× resolution, ready to paste into Word, e-mail and so on. On success “Copied to clipboard” is shown; if the browser cannot copy images, “This browser cannot copy images; use File to export” is shown, and you should use “Copy to > File...” instead.

Copy to > File...

Downloads the chart as an SVG vector image named “Curve name.svg”, which can be enlarged without loss, and shows “Vector image exported (SVG, scales losslessly)”.

Copy to > Export PNG image

Downloads the chart (including duty points, notes and watermark) as a PNG image at 2× resolution, named “Curve name.png”, and shows “PNG image exported”. Suitable for inserting into documents that do not support SVG or for sending to others. If the export fails, “Export failed. Please try again.” is shown.

Copy to > Export curve points (CSV)

Downloads the curve's data points as a CSV table named “Curve name-points.csv”, which can be opened in Excel, and shows “Curve points exported”.

The first line is the model, size (catalog curves have no size) and curve name; after one empty line comes the header “Curve type, Value, Flow (m³/h), Head (m)”.

Each row is one point on one line. The curve type is Speed (speed line; the value is the speed in r/min), Diameter (impeller diameter line; the value is the diameter in mm), Efficiency (iso-efficiency line; the value is the efficiency in %) or NPSHr (NPSHr line; the value is the NPSHr in m).

Flow is always output in m³/h and head in m, with values rounded to at most 4 decimal places.

Only the curve's own data is exported; duty points and notes are not included. An unpurchased curve does not show its curve, so it cannot be exported.

Compare To

The submenu item “None” is the current state (ticked); clicking it shows “No comparison curve”. “Existing Curve” is grayed out: overlaying curves for comparison is not yet available in the web edition.

Zoom shortcuts

The zoom range is 100% to 400%.

Action · Effect

Ctrl + 1 / 2 / 3 / 4 · Zoom directly to 100% / 200% / 300% / 400%

Shift + left click · Zoom in 50%

Shift + right click · Zoom out 50%

Ctrl + left click · Zoom in 100%

Ctrl + right click · Zoom out 100%

Mouse wheel · First click the chart to give it focus (a blue frame appears around the chart); then each wheel step zooms in or out by 7%

Click outside the chart · Removes focus; the wheel scrolls the page again

Ctrl + number keys

Press Ctrl + 1 to 4 anywhere on the curve page; you do not need to click the chart first.

Shift or Ctrl + click

When you hold Shift or Ctrl and click the chart to zoom, the info window does not appear, and holding Shift or Ctrl while right-clicking does not open the context menu.

Mouse wheel zoom

The chart must have focus (blue frame). After zooming, the chart size changes and the watermark is tiled again to fill the plot area.

Report window menus

The items of the menu bar at the top of the report window.

File > Print...

Prints the whole report; see Printed output. You can also simply press Ctrl + P in the browser, with the same result.

File > Export Image...

Same as “Copy to > File...”: downloads the SVG vector image.

File > Export PNG image

Same as “Copy to > Export PNG image” in the context menu; downloads the PNG image at 2× resolution.

File > Export curve points (CSV)

Same as “Copy to > Export curve points (CSV)” in the context menu; downloads the curve data point table.

File > Viscosity Correction

Opens Viscosity Correction in a new window and uses this curve directly to convert the performance for pumping viscous liquids (Premium feature).

File > Close Window

Closes the report window.

Edit > Copy to Clipboard

Same as “Copy to > Clipboard” in the context menu.

Edit > Clear All Annotations

Same as “Annotations > Clear All” in the context menu.

Zoom > 100% to 400%

Same as the zoom submenu of the context menu.

Zoom > Fit to Window

Returns to 100%, and the chart fits the window size again.

Printed output

The printout is one A4 landscape page: on the left the disclaimer, pump type title and chart (with duty points, notes and watermark); on the right the logo, specification table and bottom bar. The menu bar, context menu and info window are not printed. The chart is generated at a fixed scale before printing, independent of the zoom factor on screen.

Copyright line

“© month/year name” at the bottom of the specification column. The name is your custom text watermark (if you are a Premium member and have set a text watermark); otherwise it reads “PUMPVIZ. All rights reserved.”. The month/year is the current date.

TYPICAL PUMP PERFORMANCE CURVE and model box

The gray “TYPICAL PUMP PERFORMANCE CURVE” bar below the copyright line indicates that the chart shows the typical performance of this model; at the very bottom, in large type on a black background, is “Curve name/1”.

Disclaimer

The explanatory text in the top-left corner of the report window:

Catalog curves and private curves: “This curve shows the approximate performance on clear water (complying with international test standard ISO9906:1999 grade 2 unless otherwise stated). For fluids other than water, adjustments must be made for density, viscosity and/or solids. ...” That is, the curve shows water performance and must be corrected when used for slurry or other media.

Public manufacturer curves: “Generated from the manufacturer's publicly published performance table. For reference only; refer to the manufacturer's latest data.”, followed by a “Data source” link.

For partly estimated curves, an explanation of the estimate is appended to the disclaimer.

To leave more height for the chart, in the report window the disclaimer is shown as one line by default, with the rest replaced by an ellipsis; click “Expand” at the end of the line to read the full text, and click “Collapse” to go back to one line. When printing, it is always shown in full, and the “Expand” and “Collapse” buttons are not printed.

Purchase panel for unpurchased curves

A paid curve that has not been purchased is not displayed; the purchase panel is shown instead: “Purchase required to view this curve”, followed by the model, size and curve name, and “Buy once to view the full curve forever, with duty points, filter annotations and duty simulation.” For the purchase process see Curve purchases.

Sign in to buy

When you are not signed in, only the “Sign in to buy” button and “From n coins per curve” are shown. After you sign in, you return to the curve automatically.

This curve

Buys only the current curve; shows the price (coins) and the “Buy” button.

Whole model

The “Whole X model” option buys all curves of the model at once and is usually cheaper than buying them one by one. Not shown when the model is not sold as a bundle.

Payment source

Enterprise team members with permission to use the team balance can choose between “My balance (n)” and “Team balance (n)”. When buying with the team balance, “You can still spend n coins of the team balance this month” is shown (if a monthly limit is set), and the bottom of the panel notes “Curves bought with the team balance can be viewed by every member; if the team is transferred or dissolved they go to the owner personally”. See Team Edition.

Current balance

When buying with your personal balance, the bottom of the panel shows “Balance: n coins” and a “My Account” link. In the curve report window or in the embedded preview in Filter Search, clicking this link opens “My Account” in a new tab, and the original window stays as it is.

If your personal balance is not enough for even the cheapest option, the panel additionally shows “Your balance is not enough”, a “Top up” button and a “Topped up? Refresh balance” link. After topping up, return to this window and click “Topped up? Refresh balance”; the panel then refreshes with the new balance. For the top-up process see Top-up and account.

Purchase confirmation and result

After you click “Buy”, the “Confirm purchase” dialog shows the cost and the current balance; with the team balance it shows the team balance and adds “The whole team will be able to view it.” On success “Purchased” is shown and the curve loads automatically. Common failure messages:

Message · What to do

Insufficient balance. Go to My Account to top up? · Your personal balance is not enough; click “Top up” to open “My Account” and top up, see Top-up and account

Balance just changed; please retry · Click buy again

This model is not sold as a bundle · Buy single curves instead

This curve is free · Refresh the page to view it

This exceeds your monthly team balance limit (N coins) · This month's team balance allowance is used up; N is your monthly limit. Use your personal balance or contact the team owner

The team balance is insufficient. Please ask the team owner to top up · The team owner's account balance is not enough

You don't have team permission for this. Please contact the team owner · You lack the “Team balance” permission, or the team is not within its validity period

Curve types compared

Catalog curves

Pump curves in the platform's curve library; once bought individually or as a whole model, they can be viewed permanently.

Public manufacturer curves

Generated from performance tables published on manufacturers' websites; the page has the “Public manufacturer curves” tag and a “Data source” link, and the report disclaimer is different. Published material usually contains only a few duty points, so these curves are less accurate than catalog curves and are for reference only.

Partly estimated

When the original table of a public manufacturer curve has too few duty points, the shut-off and high-flow ends are estimated from typical centrifugal pump characteristics; private curves saved from Impeller quick estimate also carry this mark. The page shows the “Partly estimated” tag and an explanation; leave a margin when reading values in these sections.

Private curves

Curves you enter in Private models or import in bulk are visible only to you (and to teammates once you join an enterprise team) and do not need to be purchased. The specification table is usually empty (“-”); readings work the same as for catalog curves.

Watermark

Default watermark

The light gray word “PUMPVIZ” is tiled diagonally across the plot area of the chart. The watermark is kept on screen, in printouts, in exported SVG files, in exported PNG images and in images copied to the clipboard.

Custom watermark

Premium members can change the watermark on the account page to custom text (such as the company name), a custom image (PNG/JPG, at most 200KB) or none, and adjust its opacity; after saving, the chart, printouts and exports all use the new watermark. When custom text is set, the copyright line of the report also uses that text. See Membership and curve watermarks.

Loading... If the page does not appear, please make sure JavaScript is enabled in your browser.