Solar Irrigation Pumping and Farm Water: India's PM-KUSUM Progress, Market Signals, Groundwater Risk and Lessons for Pump Makers

Solar pumping gives off-grid farms a source of irrigation power that is free during the day, but it asks very different things of a pump than grid supply does: power follows the sun, the flow range is wide, and cheap pumping capacity can aggravate groundwater over-extraction. India's PM-KUSUM scheme is the largest policy case, while off-grid markets in Africa and South Asia offer another thread. This article draws on official figures and international agency material and ends with suggestions for pump selection and product planning.

India's PM-KUSUM: official figures to end-2025

PM-KUSUM was launched by India's Ministry of New and Renewable Energy (MNRE) in March 2019. It has three components: A, 500 kW to 2 MW decentralised solar plants on farmland; B, standalone off-grid solar pumps; and C, solarisation of grid-connected pumps, either individually or at feeder level. According to MNRE's Annual Report 2025-26, as of 31 December 2025:

  • Component B had installed more than 975,000 standalone solar agricultural pumps against an original target of 1.4 million;
  • Component C had solarised 1.2 million grid-connected pumps (the target is 3.5 million, including feeder-level);
  • Component A had installed 720.91 MW against a 10,000 MW target;
  • During 2025 alone, Components B and C together installed or solarised more than 1.448 million pumps, nearly three times the previous year, and the scheme's cumulative capacity reached 10,946 MW, about 66% (7,261 MW) of it added in 2025;
  • During the mission-mode drive from 17 September to 2 October 2025, more than 200,000 pumps were installed across the two components.

Central support under Component B is 30% of the benchmark or tender cost, whichever is lower (50% in the North East, hill states and islands). Component C allows PV capacity up to twice the pump rating, with surplus power sold to the distribution company. The state-wise table in the report shows that Component B had 1.315 million pumps sanctioned and 975,000 installed, and that progress is concentrated: Maharashtra had installed about 484,000, roughly half the national total, Haryana about 184,000 and Rajasthan about 122,000, while Telangana had 20,000 sanctioned and none installed. For manufacturers, demand is released through state tender timetables and is uneven. The figures are from MNRE's annual report; parliamentary replies at other dates differ slightly.

What international bodies say: potential, markets and risk

A 2021 joint report by the International Renewable Energy Agency (IRENA) and the Food and Agriculture Organization (FAO) says India had deployed more than 272,000 solar irrigation systems by December 2020, and cites an estimate (GOGLA, 2020) of a technical potential of at least 130 million solar pumps on smallholdings under one hectare in West, Central and East Africa and 33 million in South Asia. These are older numbers that show the order of magnitude and not recent sales.

For recent off-grid market data, the 2025 annual report published by GOGLA, the global off-grid solar association, in June 2026 records 154,842 solar water pumps sold worldwide by its affiliates in 2025, down 47% from 2024. The report states that this mainly reflects changes in which companies reported, so it should not be read as a market collapse. East Africa recorded 14,067 units (down 26%) and Kenya 11,112 (down 32%); cumulative affiliate sales since 2018 are about 655,000. Coverage of the dataset is still growing, so it is a trend indicator only.

On risk, a 2020 World Bank feature says standalone solar pumps raised farm incomes but also groundwater extraction, and suit only areas with abundant groundwater; grid-connected solar pumps that can sell power give an incentive to save water if the revenue from surplus power exceeds the value of the extracted water, and it cites a Gujarat cooperative with a 25-year power purchase agreement. A Yale E360 report quotes a World Bank economist saying the success of solar pumps is threatening aquifers that were already at risk, and notes that India is already the world's largest groundwater user. The IRENA and FAO report likewise stresses a water-energy nexus approach, for example feed-in tariffs for surplus power, to manage over-pumping.

System components and standards

A solar pumping system typically consists of a PV array, a controller or drive with maximum power point tracking, a motor and a pump, sometimes with a tank or batteries. The International Electrotechnical Commission standard IEC 62253:2011, Photovoltaic pumping systems - Design qualification and performance measurements, sets out requirements for the design, qualification and performance measurement of stand-alone PV pumping systems. Tests can be indoors with a PV simulator or outdoors with a real array, and the standard covers motor-pump sets connected to the PV generator directly or through a DC-DC or DC-AC converter. The Swedish Standards Institute page lists it as valid.

What it means for pump manufacturers

  • Design to the sun, not to a rated point: PV output can vary several-fold from morning to noon, and pump speed and power follow. Evaluate flow and efficiency across the day's speeds. Head varies with the square of speed, so below some speed the pump head falls under the static head and flow is zero; define the minimum starting speed and the PV power it needs, which is the main difference from a normal variable-speed pump. See variable-frequency pump control and use performance curves to view curves and efficiency at different speeds.
  • Wide, low-flow operation: most irrigation duty is at small flow and fairly high static head, so efficiency must hold over a wide speed range without stall or surge, and borehole motors need cooling checked.
  • Submersible versus surface pumps: deep boreholes mostly use multistage submersible centrifugal pumps; shallow wells and open channels can use surface pumps, for which suction lift and NPSH must be checked, see understanding NPSH. Positive-displacement (progressive-cavity) designs also exist for very low flow at high head. Document how each type responds to changing sunlight in the data sheet.
  • Hybrid with the grid: Component C shows that the market wants "solar first, grid as backup" systems, so pump and controller should support switching among grid, PV and generator and avoid islanding and over-current.
  • Standards and test data: giving flow-head data at several PV power levels, in the spirit of IEC 62253, is more persuasive in tenders than rated data alone. We could not verify the technical specifications that national subsidy schemes set for pumps, so check them country by country.
  • Over-extraction and product responsibility: low running cost invites over-pumping. Products can offer flow metering, daily volume caps, data logging and remote-monitoring interfaces to help authorities enforce limits, and such functions may become a plus in subsidised programmes.

References

  • Ministry of New and Renewable Energy (India), Annual Report 2025-26, data as of 31 Dec 2025, cdnbbsr.s3waas.gov.in
  • IRENA and FAO, Renewable energy for agri-food systems, 2021, irena.org
  • GOGLA, Global Off-Grid Solar Market Report: Annual Sales and Impact Data (2025 data), June 2026, gogla.org
  • World Bank, Unshackling India's Energy-Water-Agriculture Nexus: Is Solar Power the Panacea it Promises to be?, 5 Jun 2020, worldbank.org
  • Yale E360, How a Solar Revolution in Farming Is Depleting World's Groundwater, e360.yale.edu
  • IEC 62253:2011 Photovoltaic pumping systems - Design qualification and performance measurements (Swedish Standards Institute listing), sis.se

Loading... If the page does not appear, please make sure JavaScript is enabled in your browser.