Data Search

Data Search lets you browse curves by pump type, model and size (component query), or enter a flow and head to quickly list the curves that can meet the duty and compare their predicted speed and efficiency (duty selection). Entry point: “Data Search” in the left Workspace; after signing in, clicking “Workbench” also opens this page by default.

Page layout

Three-column layout

Left: the Workspace navigation.

Middle: the search criteria, arranged vertically.

Right: the top toolbar, from left to right, holds the “Search” and “Reset filters” buttons and the “Show All” check box; when there are results it also has the “View curve”, “Add to project”, “Duty Simulation” and “Columns” buttons; then comes the “?” help link (opens this chapter in a new tab) and the number of curves. Below the toolbar is the results table.

At least one search condition is required: Type, Pump Model, Pump Size, Curve Name or Impeller Name, or tick “Use Duty Conditions” and enter Flow and Head. If you click “Search” without filling in anything, the message “Please enter at least one search condition (type, model, size, curve name, or duty flow and head)” appears.

Remembered criteria

When you click “Search”, all the criteria of this search are saved in the current browser and restored automatically the next time you open Data Search. The column visibility, grouping and sorting settings of the results table are remembered as well.

Two ways to search

Usage · How · Result

Component Query · Leave “Use Duty Conditions” unticked and filter by type, model, size and name · Lists all curves that match the criteria, without calculating speed or efficiency

Duty Selection · Tick “Use Duty Conditions” and enter the flow and head · Lists only curves whose operating range contains the duty point, calculates predicted speed and efficiency, and evaluates the efficiency and NPSHa criteria

Search criteria

Type

Meaning: the installation type of the pump.

Values: All Types, Horizontal, Submersible, Vertical.

Effect: changing the type clears the selected models and sizes and reloads the model list for that type. NPSHa can be entered only for “All Types” and “Horizontal”.

Pump Model (multi)

Meaning: the pump models (series) to search; multiple selection is allowed. Selecting none means all models.

Model groups: when public manufacturer curves or private models exist, the drop-down list is grouped:

Catalog models: models in the platform's curve library.

Public manufacturer curves · category: grouped into Slurry pumps, Clean-water centrifugal pumps, Chemical process pumps, Sewage pumps, Multistage pumps, In-line pumps, Split-case double-suction pumps, Deep-well pumps, Fire pumps and Other pumps.

Private models: models you (and your teammates) have entered under Private models; a teammate's model shows the creator's name in parentheses after the model name.

Rules: when several are selected they are collapsed into tags; hover to see them all. Changing the model clears the selected sizes.

Search scope for private and public curves:

Model and size selection · Includes private curves and public manufacturer curves?

No model and no size selected · All included

Private or public models selected · Only the selected models

Only catalog models or sizes selected · Not included

“Impeller Name” entered · Not included (private and public manufacturer curves have no impeller part number)

Pump Size (multi)

Meaning: the pump sizes; multiple selection is allowed. Selecting none means all sizes of the selected models.

Rules: the list changes with “Type” and “Pump Model” and only lists sizes of catalog models. Once sizes are selected, private and public curves are no longer included in the results.

Use Duty Conditions

Meaning: when ticked, the search is a duty selection; when unticked, it is a component query.

Effect: the flow, head, NPSHa and efficiency criteria can be entered only when it is ticked. Each time you tick or untick it, the efficiency criterion is reset to “Any”.

Rules: if it is ticked but the flow or head is empty (or not greater than 0), a component query is run, without an error.

Flow

Meaning: the flow at the design duty point.

Unit: follows “Units”: L/s, m³/min, m³/h or US GPM.

Head

Meaning: the head at the design duty point (clear-water head).

Unit: m; ft when the unit is US GPM.

Effect: in a duty selection, a curve appears in the results only if both the flow and the head lie within the curve's flow range and head range.

NPSHa (m, optional)

Meaning: Net Positive Suction Head available of the installation. Leave it empty to skip the check.

Unit: same as the head.

Rules: can be entered only when “Type” is “All Types” or “Horizontal” and “Use Duty Conditions” is ticked; checked only for horizontal curves.

Criterion: NPSHa must be greater than the curve's Net Positive Suction Head required, NPSHr, at the duty point. If not, the comment is “Failed NPSHa criteria”; if the curve cannot predict NPSHr at the duty point, the comment is “Unable to predict NPSHr”, which is also treated as a failure.

Efficiency

Available after ticking “Use Duty Conditions”; choose one of three:

Mode · Input · Rule · Comment when not met

Any · — · No filtering by efficiency · —

Min Efficiency · A percentage, default 45 · The efficiency at the duty point must be greater than the input value · Efficiency below the input value: “Failed Min Eff criteria”; efficiency cannot be predicted at the duty point: “Efficiency not predicted”

% Best Efficiency Flow · Lower limit “to” upper limit, default 85 to 100 · The %BEP of the duty point (rounded to 2 decimal places) lies between the limits (inclusive) · “Failed BEP range criteria”

%BEP is calculated as:

%BEP = Q ÷ ( Q_BEP × √(H ÷ H_BEP) ) × 100

Q and H are the duty flow and head; Q_BEP and H_BEP are the best efficiency point of the curve at rated speed. The duty point is first converted to the rated speed along the affinity parabola and then compared with the BEP flow. For a detailed explanation and worked example, see Duty Simulation.

Curve Name

Meaning: fuzzy match on the curve name; it is enough for the name to contain the text entered. can be used as a wildcard for any characters.

Rules: leave empty for no restriction.

Impeller Name

Meaning: fuzzy match on the impeller part number, with the same rules as Curve Name.

Note: in a component query (whether or not an impeller name is entered), catalog curves without an impeller part number are not listed; when an impeller name is entered, neither private curves nor public manufacturer curves appear in the results.

Units

Values: L/s, m³/min, m³/h, US GPM. With US GPM, head and NPSHa are in ft, and lengths in the results table are in inches.

Effect: when you change the unit, the flow, head and NPSHa already entered are converted automatically to values in the new unit (to 2 decimal places); the duty itself does not change.

Search actions

Search

Click the “Search” button in the results pane to run the search. While searching, “Data Searching” is shown. If the search fails, the message “Search failed, please retry” appears and the results are cleared.

Search by pressing Enter

Pressing Enter in any input box in the search criteria area in the middle is the same as clicking “Search”. Pressing Enter in a drop-down only selects the option and does not trigger a search.

Reset filters

Restores all search criteria to their defaults: Type, Pump Model, Pump Size, Curve Name and Impeller Name are cleared; “Use Duty Conditions” is unticked and Flow, Head and NPSHa are cleared; Efficiency is reset to “Any”, and “Show All” is unticked. “Units” stays unchanged, and the current results table is not cleared; change the criteria and click “Search” again.

Show All

Meaning: when ticked, curves that do not meet the efficiency or NPSHa criteria are also listed (red rows), and superseded curves are listed too (grey rows).

Effect: ticking or unticking it immediately runs the search again.

Curves: N

The number of curves in the current results is shown on the right of the results pane.

View curve (toolbar)

Appears when there are results. First click a row to select it, then click this button to open that curve, the same as double-clicking that row; see Double-click.

When no row is selected, the “View curve”, “Add to project” and “Duty Simulation” buttons are grey; hovering over them shows the tip “Click a result row to select it first”.

Add to project (toolbar)

Appears when there are results. Adds the curve of the selected row to a project as a selection, the same as “Add to project” in the context menu; see Add to project dialog.

Column settings

Appears when there are results. Click to open the list of all columns; tick or untick a column to show or hide it, the same as “Show” in the context menu. At least one column always stays shown.

Duty Simulation button

When there are results, the “Duty Simulation” button appears. First click a row to select it, then click this button to open the duty simulation of that curve in a new tab: the duty of this search (clear water, no piping entered) is used as the design point; if duty conditions were not used, the best efficiency point of the curve at rated speed is used as the design point. The simulation page uses the units from the last time you clicked “Search”; if you only changed the “Units” drop-down after searching without searching again, it still opens with the units used for the search. Requires Premium membership. See Duty Simulation.

Empty results

Before you search, the results area shows “Duty selection (match by flow/head) or Component query (browse by model/curve)”, with two boxes below it: “Try an example duty” and “Recently viewed”.

If a search returns no results, “No matching results, please adjust criteria” is shown; it is not shown when there are results. You can try: relaxing the efficiency criterion, ticking “Show All”, reducing the model and size restrictions, and checking the units.

Example duties

Before you search, the “Try an example duty” box is shown, containing three example buttons, such as “Flow 300 m³/h · Head 40 m”. Clicking one automatically switches the units to m³/h, clears Type, Pump Model, Pump Size, Curve Name and Impeller Name, ticks “Use Duty Conditions”, fills in the example's flow and head, and searches immediately. It is a quick way to see what the results table looks like on first use.

Below the box are two more links: “Use the Filter for slurry duties” opens Filter Search, and “User guide” opens this chapter in a new tab.

Recently viewed

Before you search, if you have opened curve pages in the current browser, the “Recently viewed” box is shown, listing the curves you opened most recently in reverse chronological order (up to 20): curve name, model and time opened. Click a curve name to open that curve again; click “Clear” at the top right to clear the list. The list is kept separately for each signed-in account.

Result columns

Columns of the results table can be switched on and off individually under “Columns” on the toolbar or “Show” in the context menu. The table below lists all available columns.

Pump (column)

The pump size name. When you sort by this column, pumps are sorted by discharge diameter. By default the results are grouped by this column.

Curve (column)

The curve name.

Pump Type (column)

The pump model (series) name.

Comment (column)

The conclusion of the duty evaluation; multiple comments are separated by commas; “-” is shown when there is no problem. For the meaning of each comment, see Comment column below.

Predicted speed (column)

Meaning: the speed the pump needs to operate at the duty point, in r/min, interpolated from the curve's speed surface.

Display: “-” in a component query or when it cannot be predicted; a lock symbol for curves you have not purchased.

BEP (column)

The efficiency at the best efficiency point (BEP) of the curve at rated speed, in %. A value is shown only in a duty selection; a lock symbol is shown for curves you have not purchased.

Efficiency (column)

The efficiency of the pump at the duty point, in %. A value is shown only in a duty selection; “-” is shown when the value is not between 0 and 100; a lock symbol is shown for curves you have not purchased.

Seal (column)

The seal type that goes with the curve.

Liner Mtl (column)

The available liner material categories, separated by commas when there are several.

Impeller Mtl (column)

The available impeller material categories, separated by commas when there are several.

Type (column)

The installation type of the pump (horizontal, vertical, submersible).

Impeller (column)

All impeller part numbers that apply to the curve, separated by commas when there are several.

Min Passage Size (column)

The largest particle size that can pass through the pump, in mm (inches in the US GPM system).

Vane σ (column)

The impeller vane diameter, in mm (inches in the US GPM system).

Vane (column)

The number of vanes and the vane type code, for example “5v” followed by the type letter.

Speed (column)

The maximum rated speed allowed by the liner (r/min). Hidden by default; it can be turned on under “Columns” on the toolbar or “Show” in the context menu.

Price (column)

The purchase status of the curve for the current account: “✓ Owned”, “Free”, “Private” or “N coins”. This column is always shown on the far right, cannot be hidden and does not appear under “Columns” or under “Show” in the context menu; it is not shown when the platform has not enabled curve charging. After you buy a curve in the curve window that pops up, the column refreshes automatically to “✓ Owned” when you return to the results page (when the window regains focus). See Curve purchases.

Column labels

Lock icon before the first column: a paid curve that you have not purchased.

“Public” tag: a public manufacturer curve.

“Private” tag: a private curve; a teammate's private curve shows “Private · creator”.

Row colors

The text of result rows is uniformly dark; the outcome is shown by the color of the small dot before the first column:

Color · Meaning

Blue dot · Meets all criteria (all rows are blue in a component query)

Red dot · A criterion is not met; see the comment for the reason. Appears only when “Show All” is ticked

Grey dot, grey text · The curve is superseded. Appears only when “Show All” is ticked

Light blue background, blue bar at the start of the row, bold text · The currently selected row

Comment column

Curve Superseded

A newer version of the curve exists or it has been discontinued; it is not recommended for selection. Shown as a grey row.

Unable to predict NPSHr

NPSHa was entered, but the curve has no NPSHr data at the duty point, so cavitation cannot be checked; it is treated as a failure.

Failed NPSHa criteria

The NPSHr at the duty point is not less than the NPSHa you entered; there is a risk of cavitation.

Failed BEP range criteria

The %BEP of the duty point is not within the range set for “% Best Efficiency Flow”.

Efficiency not predicted

“Min Efficiency” was selected, but the curve cannot give an efficiency at the duty point (for example, the point lies outside the efficiency surface).

Failed Min Eff criteria

The efficiency at the duty point is not higher than the “Min Efficiency” value.

Within duty range · buy to see speed/efficiency

A curve you have not purchased: the duty point is within the operating range. Speed and efficiency are shown only after purchase, and only then does the curve take part in efficiency and NPSHa filtering.

Duty point outside this curve's range

A curve you have not purchased: the duty point is not within the operating range (red row, appears only with “Show All”).

Grouping and sorting

Group By

By default the results are grouped by the “Pump” column, with a grey group header row before each group. Under “Group By” in the context menu you can group by any visible column instead, or choose “No Grouping”.

Public manufacturer curves and private curves are not included in this grouping and are always placed after the catalog curves: first the “Public manufacturer curves · category (N)” groups (light blue headers), and last the “Private models (N)” group (light orange header).

If you hide the column currently used for grouping, grouping is cancelled automatically.

Sorting

Click a column header to sort by that column; click again to reverse the order. The header shows ▲ or ▼. Numeric columns are sorted by value, text columns in natural order. Sorting applies within each group.

Paging

When the results (including group header rows) exceed 100 rows, they are paginated and page numbers appear below the table. After you change the search, grouping or sorting, you return to page 1.

Context menu

Right-click a result row to open the menu; the row is selected at the same time (you can also right-click a column header, but then only “Show” and “Group By” are available).

Show

The submenu lists all columns; those with ✓ are currently shown. Click to show or hide a column. At least one column must remain.

Group By (menu)

The submenu lists “No Grouping” and all visible columns; the one with ✓ is the current grouping.

View

Opens the curve, the same as double-clicking.

Duty Simulation (menu)

Opens the duty simulation for this curve, the same as the “Duty Simulation” button in the results pane.

Add to project

Adds the curve as a selection to a duty of a project; see Add to project dialog below. If you are not signed in, you are taken to the sign-in page.

Double-click and click

Click

Selects the row (light blue background), for use with the “View curve”, “Add to project” and “Duty Simulation” buttons on the toolbar.

Double-click

Opens the curve page in a separate floating window. By default the window is about 70% of the screen width and 80% of its height, centered; once you have resized a curve window, later curve windows open at the adjusted size. Double-clicking the same curve again reuses the window that is already open. In a duty selection, the search duty is marked automatically on the curve as duty point “DP01” (together with the NPSHa, if entered). For a curve you have not purchased, the purchase panel is shown first. See Curve Viewer.

Add to project dialog

Opened by clicking “Add to project” in the context menu or on the toolbar; the title is “Add to project”. The project selection list and “Add to project” in step 6 of Filter Search also use this same dialog.

Project (dialog)

Choose an existing project, or the last item, “+ New project”. By default the project you last used to add a selection is selected (remembered in the current browser); if that project no longer exists, the first project in the list is selected; if you have no projects, a new one is created by default.

Project name (dialog)

Appears when “+ New project” is selected; required, up to 128 characters, and must not have the same name as one of your existing projects.

Duty (dialog)

Lists the duties of the selected project (“No. Equipment name · Tag number”), or choose “+ New duty”. By default the duty used the last time you added a selection is selected, otherwise the first duty is selected; if the project has no duties, “+ New duty” is selected by default.

Equipment name (dialog)

Appears when “+ New duty” is selected; required, up to 128 characters.

Default tag number (dialog)

Appears when “+ New duty” is selected; the default tag number of the new duty. Can be left empty; up to 64 characters.

Add as

“Primary selection” or “Alternative selection”. When adding to a new duty or to a duty that has no selections, it can only be added as the primary selection. When you set it as primary, the duty's previous primary selection automatically becomes an alternative.

Tag number (dialog)

The tag number of this selection. Can be left empty (the duty's default tag number is then used); up to 64 characters.

OK

Saves and shows the message “Added to project”, with an “Open project” link in the message; click it to go directly into that project. Possible errors:

Message · Meaning

Please enter a project name / Please enter an equipment name · The name is empty when creating a new project or duty

A project with this name already exists · Choose another project name

You have reached the limit of 200 projects · Delete projects you no longer use

A project can have at most 100 duties · Add it to an existing duty or to another project instead

A duty can have at most 50 selections · Delete selections you no longer use

You don't have team permission for this. Please contact the team owner · You do not have team permission to modify this project

Selections added from Data Search

Data Search only has a clear-water duty (flow, head, NPSHa, based on clear water at 20 °C), with no slurry, piping or configuration. Selections added from it are therefore shown as “Needs recalculation” in the project, and the summary table and eQuote export lack their results. Open the selection in the project, click “Open in Filter Search”, complete the configuration and then click “Save back to…” to fill them in. See Projects.

Usage tips

When to use Filter Search

Data Search evaluates curves on a clear-water duty and does not take into account slurry derating, piping, materials or engineering checks. When pumping slurry, or when you need a formal selection report, use Filter Search.

Private curves not found

Make sure you have not selected only catalog models or sizes: clear both the model and size selections, or select your model in the “Private models” group of the model drop-down. Also clear “Impeller Name”, and make sure “Type” matches the installation type of the curve.

Loading... If the page does not appear, please make sure JavaScript is enabled in your browser.