Filter Search 1: Fluid details

This chapter covers step 1 of Filter Search, “Flow Details”: here you choose the pump type, duty mode and units, and enter the flow and the slurry (mixture) properties. The page calculates the unknowns among S, Sm, Cv and Cw in real time, together with the head ratio HR, efficiency ratio ER, solids mass flow and settling velocity; these results are passed on to the head calculation, the curve search and the engineering checks that follow.

Where to open it: after signing in, click “Filter Search” in the left workspace (not “Data Search”).

Page overview

The Filter Search page has three columns:

Area · Content

Left column · Step navigation for the 6 steps (completed steps show a tick, steps not yet available are greyed out and can be clicked to jump directly), with the “Current duty” summary below: flow Q, head H, Sm, Cv, HR / ER, settling velocity Vs; once a curve is selected, “Selected curve” is also shown, with its predicted speed n and efficiency η

Middle · The content of the current step. A title bar at the top shows the step number and name, “? Help for this step”, “Back” and “Next”; the title bar stays at the top as the page scrolls

Right column · The “Select Assist” engineering check panel, visible in all 6 steps; see Select Assist (Engineering checks)

The content of this step, from top to bottom, is:

Position · Content

Top row · Pump type, units, slurry type, Single Duty / Use Range; when “Use Range” is selected, the Range Values box appears below

Main body · Known flow condition and known slurry condition, mixture properties, slurry properties, optional particle details, sections specific to a slurry type (Froth / Non-Newtonian / Two Solid Mixture / Coal Mixture), and the calculated results row (including the “Settling velocity method”)

Every time you change an input, the page recalculates automatically (after about 0.3 seconds); there is no button to click.

The “Select Assist” panel on the right refreshes at the same time, and the results of the flow, mixture, mass flow, temperature and other checks are shown immediately; see Select Assist (Engineering checks) for details.

When you are done, click “Next” in the title bar to go to Filter Search 2: Head details; “Back” returns to the previous step.

Tip: The fields shown depend on the slurry type. For the differences between types, see “Fields by Slurry Type” at the end of this chapter.

Common wizard actions

The following actions apply to all 6 steps of the filter.

Step progress and help for this step

In the left-column step navigation, the current step is highlighted and completed steps show a tick; click a step name to jump straight to that step (step 5 requires a curve to be selected first, and step 6 requires the selected curve to have a predicted speed and efficiency). In the middle title bar, the “? Help for this step” link opens the user guide chapter for the current step in a new tab, without affecting what you are entering.

Automatic draft saving

After you change any input in the filter, the system automatically saves your current inputs and step as a draft. The draft is kept in the current browser, separate for each login account, and does not use up your saved selection quota.

The next time you open the filter, the draft is restored automatically, with the message “Your unfinished input from last time has been restored (saved time) · Clear”. Click “Clear” to discard the draft; the filter returns to its initial state.

A draft restores up to step 4, “Curve Selection”: search results and selected curves are not kept in the draft. After restoring, click “Search” again in step 4 and select a curve to continue.

When you open the filter from “Saved Selections” or from a project option, it is restored from the saved selection and the draft is not used.

After “Save as selection”, “Save back to “…”” or “Add to project” succeeds, and after you confirm “New Search”, the draft is cleared automatically.

The draft is only kept in the current browser; it will not carry over to another browser or computer. To keep a selection for the long term, use “Save as selection” in step 6; see Filter Search 6: Project options.

Leave-page reminder

When there are unsaved changes (compared with when the page was opened or the last save):

If you switch to another page within the site, a “Leave page” confirmation appears: “You have unsaved changes (saved as a draft that will be restored next time you open this page). Leave anyway?” Click “Leave” to continue to the other page, or “Stay on page” to cancel.

When you close the tab or refresh the page, the browser shows its own leave confirmation.

Even if you choose to leave, your input has already been saved as a draft and can be restored the next time you open the filter.

Pump Type and duty mode

Pump Type

Meaning: the installation type of the pump: “Horizontal”, “Vertical” or “Submersible”.

Default: Horizontal.

Effect on calculations and results:

The curve search covers only curves of the selected pump type; after changing the pump type, the models and sizes already selected on the “4 Curve Selection” page are cleared.

Only horizontal pumps use the suction pipe and calculate NPSHa; vertical and submersible pumps ignore the suction pipe, and the NPSHa check shows “NPSHa Ignored.”.

Vertical and submersible pumps can only run single stage: when you switch to one of these pump types, the pump system in “3 Preferences” is automatically reset to single stage and the number of pumps to 1.

The “Zl (Dredging)” input is available only for horizontal single-stage pumps with slurry type Single Solid or Water; the options of “Pump Application” also change with the pump type; see Filter Search 3: More options for details.

Single Duty

Meaning: selection by one duty point (flow Q + head).

Default: selected.

When you choose Froth, Non-Newtonian, Two Solid Mix or Coal Mixture, the page switches back to Single Duty automatically.

When you switch from “Use Range” back to Single Duty, the min/max flow and min/max head in the Range Values box are cleared.

Use Range

Meaning: selection by three duty points (minimum, nominal and maximum), suitable where the flow or system resistance varies considerably.

Available when: the slurry type is “Single Solid” or “Water”; grayed out for other types.

Effect on calculations and results:

When selected, the “Range Values” box appears; enter three sets of flow and head.

The curve search first uses the nominal duty point to find candidate curves whose flow and head range cover it, then predicts speed and efficiency at the maximum duty point (maximum flow, maximum head) and applies the efficiency and NPSHa filters there, ensuring that the selected pump can cover the maximum duty.

The “Min” and “Max” columns of the “Select Assist” panel start giving results (flow, NPSHa, pipe velocities, expeller, etc.), and once a curve is selected the speeds at the minimum and maximum duties are predicted separately.

Min Flow (Range Values)

UI text: “Min:”, in row 1 of the Range Values box.

Unit: follows the unit system: L/s, m³/hr, m³/min or USGPM.

What to enter: the minimum operating flow that can occur in the system.

Related check: if left empty, the Min column of the “Flow (Q)” check shows a warning.

Nominal Flow (Range Values)

UI text: “Nominal:”.

It is the same value as the volume flow Q in “Mixture Properties” on the right; changing either one updates the other.

Max Flow (Range Values)

UI text: “Max:”.

Unit: same as Min Flow.

What to enter: the maximum operating flow that can occur in the system; it should not be less than the nominal flow.

Related check: if left empty, the Max column of the “Flow (Q)” check shows a warning; the maximum duty point cannot be determined either (likewise when Max Head is empty), and the search still uses the nominal point.

Calculate min & max head from system curve

Meaning: when ticked, the min head and max head are no longer entered by hand; instead, the system head is calculated for the min flow and the max flow from the piping entered on the “2 Head Details” page and filled in automatically.

Default: not ticked.

Prerequisite: the piping information on the “2 Head Details” page is complete (horizontal: inner diameter and TEL of the suction pipe and of discharge section 1 all greater than 0; vertical/submersible: inner diameter and TEL of discharge section 1 greater than 0). If the piping is incomplete, no values are filled in.

Linked behavior: when ticked, the Min Head, Nominal Head and Max Head boxes are grayed out. If you change the slurry head on the “2 Head Details” page from “Calculate” to “Define”, the “Min / Max Head” dialog pops up; see Filter Search 2: Head details for details.

Min Head (Range Values)

UI text: “Min Head”.

Unit: m; ft when the unit system is “USGPM, ft”.

Meaning: the slurry head at the minimum duty point.

Nominal Head (Range Values)

UI text: “Nominal Head”.

It is the same value as the “Slurry Head” on the “2 Head Details” page.

Max Head (Range Values)

UI text: “Max Head”.

Unit: same as Min Head.

Meaning: the slurry head at the maximum duty point; together with the max flow it is the filter point for the curve search.

Units

UI text: “Units:”.

Options:

Option · Flow unit · Head unit

L/s, m (default) · L/s · m

m³/hr, m · m³/hr · m

m³/min, m · m³/min · m

USGPM, ft · USGPM · ft

Scope: affects only the flow inputs (Q, min/max flow) and the head-type inputs (slurry head, min/max head, NPSHa override, Zl, suction/discharge static head). The following quantities always use fixed units: solids mass flow t/h, particle size µm, temperature °C, pipe inner diameter mm, TEL m, terminal pressure kPa, altitude m, all velocities m/s, aerated flow L/s, and the total slurry flow of the coal mixture L/s.

Remembered: the selected units are stored in the current browser and are still used after refreshing or the next time you open the page.

Conversions: 1 m³/hr = 1/3.6 L/s; 1 m³/min = 1/0.06 L/s; 1 USGPM ≈ 0.06309 L/s; 1 ft = 0.3048 m.

Tip: When you switch units, the flow and head values already entered are converted automatically to the new units; the duty itself does not change. For example, if you entered Q = 50 under “L/s, m”, switching to “m³/hr, m” shows Q = 180. When a selection is restored from “Saved Selections”, it is shown in the units it was saved with, without conversion.

Slurry Type and known conditions

Slurry Type

Meaning: the category of the pumped medium; it determines which fields the page shows and which HR/ER calculation method is used.

Options and default:

Option · Application · Automatic settings after switching

Single Solid (default) · Ordinary slurry: water with one kind of solid particles · The HR/ER method is kept or reset to the first item in the list

Water · Clear water · S = Sm = 1, Cv = Cw = 0, HR = ER = 1

Non-Newtonian · High-concentration, fine-particle slurries with Bingham plastic behavior (pastes, thickened tailings, etc.) · HR/ER method set to “Non-Newtonian”; slurry head forced to “Calculate”; if yield stress or rigidity is not filled in, the “Bingham Plastic Slurries” library opens automatically; for horizontal pumps the pump application is set to “Froth”

Froth · Aerated slurries such as flotation froth · HR/ER method set to “Froth”; pump application set to “Froth”

Two Solid Mix · Magnetite + coal in dense-medium coal preparation · Preset Sm, d50 and HR/ER are applied according to the selected mixture type

Coal Mixture · Coal slurry in coal preparation plants (coal + magnetite dense medium) · The “Coal Mixture” section is shown; Sm, Cw and HR/ER are determined by that section

Related note: apart from Single Solid and Water, all types can only use Single Duty.

Known Flow Condition

Options: “Volume Flow” (default) or “Solid Mass Flow”.

Shown when: hidden when the slurry type is “Water” or “Two Solid Mix”. If you switch to one of these types while “Solid Mass Flow” is selected, it is reset automatically to “Volume Flow” and the Q box becomes available again.

How to choose:

If you know the volume flow of slurry to be pumped, choose “Volume Flow” and enter Q under “Mixture Properties”.

If you only know how many tonnes of dry solids per hour must be transported, choose “Solid Mass Flow”: the Q box is then grayed out, a “Solid Mass Flow” box (t/h) is added below, and the volume flow is calculated back from the mass flow.

Known Slurry Condition

Meaning: which two of the four quantities S, Sm, Cv and Cw you know; the other two are calculated by the program.

Options: “S, Sm”, “S, Cv”, “S, Cw” (default), “Sm, Cv”, “Sm, Cw”.

Shown when: hidden when the slurry type is “Water” or “Two Solid Mix”.

Effect on the interface: in the “Slurry Properties” box, the two fields of the selected pair can be entered; the other two are grayed out and show the calculated results.

Known pair · Editable · Calculated

S, Sm · S, Sm · Cv, Cw

S, Cv · S, Cv · Sm, Cw

S, Cw · S, Cw · Sm, Cv

Sm, Cv · Sm, Cv · S, Cw

Sm, Cw · Sm, Cw · S, Cv

Common mistake: after switching pairs, a field that has just become editable may be empty and must be filled in; otherwise the “Sm, Sw, Cw, Cv” check fails.

Mixture Properties

Volume flow Q

Meaning: the volume flow of slurry pumped (the flow of the whole system). For froth, this is the flow after de-aeration; see “Aerated flow Qf”.

Unit: follows the unit system.

Default: 0.

Available when: grayed out when “Known Flow Condition” is “Solid Mass Flow”. The grayed-out box keeps the previously entered value for display only; the duty calculation uses the volume flow calculated back from the mass flow.

Related check: if Q is 0 or invalid, the “Flow (Q)” check fails with “Invalid flow rate. Please check flow rate”.

Effect on results: determines pipe velocities, pipe friction, system head, NPSHa, solids mass flow and the flow point of the curve search. With several stages in series, the flow of each pump equals Q (see Filter Search 3: More options).

Solid Mass Flow (input)

Meaning: the mass of dry solids transported per hour.

Unit: t/h.

Shown when: “Known Flow Condition” is “Solid Mass Flow”.

Relation:

Q (L/s) = M (t/h) ÷ (0.036 × Sm × Cw)

where Cw is entered as a percentage (e.g. 30 for 30%).

Related check: if the mass flow is 0 or invalid, the “Mass Flow Rate” check fails with “Invalid Mass Flow Rate. Check mass flow rate and d50”.

Liquid SG Sw

Meaning: the specific gravity of the carrier liquid (relative to clear water at 4 °C); 1.0 for clear water, slightly above 1 for saline water or a liquid phase containing fine slimes.

Default: 1.0.

Range: 1.0 ≤ Sw < 1.4. Outside this range the box turns red with the message “Invalid Sw value. Sw must be >= 1 and < 1.4”, and the “Sm, Sw, Cw, Cv” check fails with “Sw is out of range. Specify Sw between 1.0 and 1.4”.

Shown when: hidden for “Water”; grayed out for “Two Solid Mix”.

Effect on results: used in converting between S, Sm, Cv and Cw; for dredging, used in the Zl differential pressure loss calculation. For the Coal Mixture type it is the same value as Liquid S in the “Coal Mixture” section.

Particle Size d50

Meaning: the median diameter of the solid particles, i.e. 50% of the particles by mass are smaller than this size.

Unit: µm.

Default: 1 µm (equivalent to extremely fine particles, with HR and ER essentially 1); enter the actual particle size.

Shown when: hidden for “Water”; grayed out for “Non-Newtonian” and “Two Solid Mix”. For the Coal Mixture type it can be entered, but the calculation always treats the particles as extremely fine.

What to enter: take it from the particle size analysis report; if unknown, use “Particle Properties Lookup” to pick a reference value from common materials.

Effect on results: the larger d50, the lower the HR and ER calculated by methods such as WB Slurry Based (more head and efficiency derating); the settling velocity changes with d50.

Related checks: if d50 is invalid, the “Mass Flow Rate” check fails; the suction/discharge pipe velocity checks show “Settling velocity cannot be calculated.Check d50, S & Cv”.

Particle Properties Lookup

Interface: the “…” button to the right of “Particle Properties Lookup”.

Function: opens the “Solids Lookup” dialog; choose an item from the list of common materials to fill in the solids SG S and particle size d50 automatically.

Available when: hidden for “Water”; grayed out for “Two Solid Mix”.

For the dialog, see “Solids Lookup dialog” in this chapter.

Temperature T

Meaning: the slurry temperature.

Unit: °C.

Default: 20; if left empty, 20 °C is used.

Effect on results: used to calculate the saturated vapor pressure of the liquid, which affects NPSHa (the higher the temperature, the lower the NPSHa); see Filter Search 2: Head details.

Related check: below 0 °C the “Temperature” check fails with “Check temperature”.

Slurry Properties

This box is hidden when the slurry type is “Water”. Which two of the four SG/concentration fields can be entered is determined by “Known Slurry Condition”; the other two are grayed out and show calculated values.

Solids SG (S)

Meaning: the specific gravity of the solid particles themselves (relative to clear water). Common quartz sand is about 2.65, iron concentrate about 4.5–5.0.

Default: 1 (change it to the actual value).

Display precision: calculated values are shown with 2 decimal places.

Effect on results: used in the concentration conversions; the larger S, the higher the settling velocity and the larger the HR/ER derating.

Common mistake: keeping the default value 1 prevents Cv, Sm, etc. from being converted correctly.

Slurry SG Sm

Meaning: the overall specific gravity of the slurry (solids + liquid); it can be measured with a pycnometer or density meter.

Display precision: calculated values are shown with 3 decimal places.

Effect on results: used to convert pressures into slurry column heights (terminal pressure, NPSHa, working pressure) and to calculate the mass flow.

Vol. Conc. Cv

Meaning: the volume of solids as a percentage of the total slurry volume.

Unit: %.

Effect on results: affects the settling velocity and the HR/ER of methods such as WB Pump Based, WB Standard and ANSI/HI.

Weight Conc. Cw

Meaning: the mass of solids as a percentage of the total slurry mass.

Unit: %.

Default: 0. For slurry, Cw = 0 makes the “Sm, Sw, Cw, Cv” check fail with “Please check mixture properties S, Sm, Cw & Cv”.

Effect on results: affects the HR/ER of the WB Slurry Based method and the solids mass flow.

Fines (-75µm) wt% of total solids Cwfp

Meaning: the mass percentage of fines smaller than 75 µm in the total solids.

Values: 5% (default), 10%, 15%, 20%, 25%.

Effect on results: used by the WB Standard and ANSI/HI methods to calculate HR; the more fines, the smaller the derating. Other methods do not use this value.

Relations between S, Sm, Cv and Cw

The program converts between them using the following general relations (Cw and Cv in percent):

Sm = Sw / [1 − (Cw/100) × (S − Sw) / S]
Cv = (Sm − Sw) / (S − Sw) × 100
Cw = 100 / [1 + (Sw / S) × (100 − Cv) / Cv]
Solids mass flow M (t/h) = Q (L/s) × 0.036 × Sm × Cw

Worked example (assumed data): S = 2.65, Sw = 1.0, Cw = 30%, Q = 50 L/s.

Sm = 1.0 / [1 − 0.30 × (2.65 − 1.0) / 2.65] = 1.0 / 0.8132 ≈ 1.230
Cv = (1.230 − 1.0) / (2.65 − 1.0) × 100 ≈ 13.9 %
M  = 50 × 0.036 × 1.230 × 30 ≈ 66.4 t/h

Optional Particle Details

The box title is “Optional Particle Details (not used in calculations)”; it is hidden when the slurry type is “Water”. The data here is for record only: it is saved with the selection and is not used in any calculation or filtering.

Coarse Particle Duty

Meaning: the largest particle size that may occur in the duty.

Unit: mm.

Use: lets the person making the selection compare it with the pump's minimum passage size (the results list of “4 Curve Selection” can show a minimum passage column) and judge for themselves.

PH Value

Meaning: the acidity/alkalinity of the slurry, for reference when choosing wetted-part materials.

Solids Lookup dialog

Opened with the “…” button of “Particle Properties Lookup”; the title is “Solids Lookup”.

Material list

Column · Meaning

Solids Lookup · Material name

S · Solids SG of the material

d50 · Typical median particle size, in microns (µm)

OK (Solids Lookup)

The “OK” button becomes available only after you click to select a row.

Click “OK” to fill the S and d50 of the selected row into the page and close the dialog.

Note: The S filled in is used in the calculation only when “Known Slurry Condition” includes S (S, Sm / S, Cv / S, Cw); with “Sm, Cv” or “Sm, Cw” S is calculated by the program and the filled-in value has no effect.

Close (Solids Lookup)

Closes the dialog without making any changes.

Froth

When the slurry type is “Froth”, the “Froth” section appears. Froth contains many air bubbles, so the volume actually entering the pump is larger than that of the de-aerated slurry; the flow must be scaled up by the froth volume factor and derated.

Froth Type

Options: Brittle, Medium, Tenacious, Custom.

Default: Custom.

Linked behavior: when you switch the type, the froth volume factor is set automatically to the lower limit of that type and the allowed input range is restricted:

Froth type · FVF after switching · Allowed FVF range

Brittle · 1.1 · 1.1–1.25

Medium · 1.205 · 1.205–1.5

Tenacious · 1.5 · 1.5–1.75

Custom · 1.0 · 1.0–1.75

How to choose: choose Brittle for froth that breaks easily and de-aerates quickly; choose Tenacious for sticky, persistent froth that is hard to break; if you have a measured FVF, choose Custom and enter it directly.

Froth Volume Factor FVF

Meaning: the Froth Volume Factor, i.e. the ratio of the volume of aerated froth to the volume of the de-aerated slurry.

Range: see the table above; step 0.005, 3 decimal places.

Default: empty the first time Froth is selected.

Effect on results:

Flow used in calculations = entered Q × FVF.

The “Froth” HR/ER method calculates the derating from FVF: up to an FVF of 1.4 a fixed small derating is applied; above that, the derating increases rapidly with FVF. The maximum FVF is 1.75, the valid range of the empirical froth derating formula; larger values would bring HR close to 0 and make no sense.

Common mistake: if FVF is empty, the flow is not scaled up and HR/ER are calculated with the WB Slurry Based method, giving optimistic results. After choosing Froth, first choose a froth type or enter FVF directly.

Aerated flow Qf

Meaning: the flow actually entering the pump including the air bubbles, Qf = Q × FVF.

Unit: always L/s.

Shown when: the calculated flow is greater than 0 (read only).

Worked example (assumed data): Q = 40 L/s and FVF = 1.5 give Qf = 60 L/s.

Non-Newtonian

When the slurry type is “Non-Newtonian”, the “Non-Newtonian” section appears. The particle size d50 is then grayed out, the slurry head on the “2 Head Details” page is fixed in “Calculate” mode and the piping must be entered; pipe velocities are judged against the critical velocity instead; see Filter Search 2: Head details.

Yield Stress τ₀

Meaning: the shear stress that must be overcome for a Bingham plastic slurry to start flowing; the higher the concentration and the finer the particles, the higher the yield stress.

Unit: Pa.

Default: 0.

What to enter: take it from rheology tests, or use “From Library…” to pick data for a similar slurry from the Bingham plastic slurry library.

Effect on results: together with Sm it determines the critical velocity (laminar/turbulent transition velocity) and the recommended pipe inner diameter; after a change, the inner diameter of discharge section 1 is automatically changed to the critical diameter for the current flow.

Slump Plate Reading

Options: Reading 3-5 (default), Reading 5-7.

Meaning: the slump plate test reading, reflecting the flowability of the slurry; the higher the reading, the better the flowability.

Effect on results: the “Non-Newtonian” HR/ER method takes fixed HR and ER values according to the reading band; the derating for Reading 5-7 is smaller than for Reading 3-5.

Rigidity η

Meaning: the Bingham plastic viscosity (coefficient of rigidity).

Unit: Pa·s.

Note: recorded with the slurry data; at present HR/ER and the critical velocity are determined only by the yield stress, Sm and the slump plate reading.

From Library…

Function: opens the “Bingham Plastic Slurries” dialog; selecting an item fills in the yield stress and rigidity.

When you switch to Non-Newtonian and the yield stress or rigidity has not been filled in yet (not greater than 0), this dialog pops up automatically.

Bingham Plastic Slurries dialog

The title is “Bingham Plastic Slurries”; it lists the rheological parameters of a number of typical Bingham plastic slurries.

Slurry list

Column · Meaning

Label · Slurry name/number

Cw % · Weight concentration the data applies to

Particle Size (µm) · Particle size characteristic written as “percent% - size”; e.g. “80% - 75” means 80% of the particles are smaller than 75 µm

Yield Stress · Pa, 3 decimal places

Rigidity · Pa·s, 5 decimal places

Selecting a slurry

Click “OK” at the end of a row, or double-click the row, to fill the yield stress and rigidity of that row into the “Non-Newtonian” section and close the dialog.

The library data are typical values at the stated concentration and particle size; if your slurry's concentration or particle size differs, use measured values.

Close (Bingham Plastic Slurries)

Closes the dialog without filling in any values.

Two Solid Mix

When the slurry type is “Two Solid Mix”, the “Two Solid Mixture” section appears; it is used for slurries in dense-medium coal preparation in which magnetite and coal are present together. Sw, d50 and “Particle Properties Lookup” are then grayed out, and “Known Flow Condition” and “Known Slurry Condition” are hidden.

Mixture Type

Options: “Dilute Medium (magnetite + coal)” (default), “Heavy Medium (magnetite + coal)”.

Effect on results: each type has a set of preset slurry SG Sm, particle size and HR/ER; Heavy Medium has a higher Sm and more derating. Once selected, inputs such as S and Cw in the “Slurry Properties” box are not used in calculations, and HR/ER also follow the presets (when “User Defined...” or “Coal Industry” is selected in “3 Preferences”, the values in that dialog apply).

Related checks: the mass flow check passes directly; the suction/discharge pipe velocity checks show “Using two solid mixture” and pass, without a settling velocity assessment.

Coal Mixture

When the slurry type is “Coal Mixture”, the “Coal Mixture” section appears. The program calculates the slurry Cw and Sm from the coal feed rate, total slurry flow and the SGs of the components, and takes HR/ER according to the selected pump function. The S, Sm, Cv and Cw entered by hand in the “Slurry Properties” box are then not used: S is taken from Coal S, Sm and Cw from the results of this section, and the particles are treated as extremely fine.

Coal Feed Rate

Meaning: the amount of dry coal entering this pump.

Unit: t/h.

Total Slurry Flow

Meaning: the total slurry flow of coal + dense medium, used to calculate Cw and Sm.

Unit: always L/s, regardless of the unit system.

What to enter: usually the same duty as the volume flow Q in “Mixture Properties”; keep them consistent (note that Q is entered in the selected unit system).

Coal S

Meaning: the specific gravity of the coal.

Default: 1.4.

MAG S

Meaning: the specific gravity of the magnetite.

Default: 4.5.

Medium S

Meaning: the specific gravity of the dense medium (magnetite + liquid).

Default: 1.5.

Liquid S

Meaning: the liquid SG; the same value as the liquid SG Sw in “Mixture Properties”.

Default: 1.0.

Cyclone Diameter

Meaning: the diameter of the downstream dense-medium cyclone; used only to estimate the cyclone pressure and does not affect the selection calculations.

No. of Cyclones

Meaning: the number of cyclones in parallel; used only to estimate the cyclone pressure.

HR (Coal Mixture)

Meaning: head ratio. Default 0.85; clicking a row of the preset table below fills in that row's value automatically, and you can also change it by hand.

Effect on results: for the Coal Mixture type it is used directly as the HR of the duty; the HR/ER method selected in “3 Preferences” has no effect.

ER (Coal Mixture)

Meaning: efficiency ratio. Default 0.85; used in the same way as HR.

Cw / Sm / Cyclone Pressure (live calculation)

Three results are shown live in the middle of the section; “-” is shown when inputs are missing:

Cw: slurry weight concentration (%, 1 decimal place).

Sm: slurry SG (3 decimal places).

Cyclone Pressure: the cyclone pressure estimated from Sm and the cyclone diameter and number (kPa, rounded), for reference only; to include the cyclone inlet pressure in the system head, enter it as “Terminal Pressure” on the “2 Head Details” page.

How Cw and Sm are calculated (volumes in m³/h, masses in t/h):

Total slurry volume = total slurry flow (L/s) × 3.6
Coal volume         = coal feed rate ÷ Coal S
Medium volume       = total slurry volume − coal volume
Medium mass         = medium volume × Medium S
Magnetite mass      = medium mass × mass fraction of magnetite in the medium (from MAG S and Medium S)
Sm = (coal feed rate + medium mass) ÷ total slurry volume
Cw = (coal feed rate + magnetite mass) ÷ (coal feed rate + medium mass)

Pump Function preset table

Columns: Pump Function, HR, ER.

Preset rows: Cyclone Feed(40mm coal size), Cyclone Feed(8mm coal size), Flotation Feed, Filtrate, Correct Density Medium, Over Dense Medium, Dilute Medium, Thickener Underflow, Tailings Disposal (Fine Coal Only).

Use: click the row closest to the pump's purpose; HR and ER are filled into the boxes above and recalculated immediately.

Calculated results at the bottom

The bottom row of this step shows the calculated results for the current mixture; “-” is shown when a value is 0 or cannot be calculated. At the right end of the same row is the “Settling velocity method”.

Hr and Er

Meaning: the head ratio HR and efficiency ratio ER calculated with the current HR/ER method (2 decimal places).

Note: HR = slurry head ÷ water head, ER = slurry efficiency ÷ water efficiency; see Filter Search 3: More options for details.

Solid Mass Flow (calculated)

Meaning: the dry solids mass flow calculated from Q, Sm and Cw (t/h, 1 decimal place). When “Solid Mass Flow” is chosen as the known flow, the value shown here is the input value.

Settling Velocity

Meaning: the critical pipe velocity at which solid particles start to deposit at the bottom of a horizontal pipe (also called the limit deposit velocity); below it the pipe is at risk of blockage.

Unit: m/s (2 decimal places).

Calculation: determined by “Settling velocity method” below; by default the common Durand-type formula is used:

V_L = F_L × √(2g × D × (S − 1))

where D is the pipe inner diameter (m) and F_L is the settling velocity factor looked up from d50 and Cv.

Note: the settling velocity on this page is calculated for a reference pipe diameter of 100 mm and serves only as a quick indication of the slurry's settling behavior; the settling velocity of each actual pipe section is calculated for its own diameter on the “2 Head Details” page and compared with the pipe velocity.

Worked example (assumed data): S = 2.65, D = 0.1 m and an assumed F_L = 1.0 give V_L = 1.0 × √(19.62 × 0.1 × 1.65) ≈ 1.80 m/s.

Settling velocity method

Meaning: the formula used to calculate the settling velocity. Two methods are available; choose the one that fits your company's engineering practice.

Options:

Option · Description

Durand formula (all pipe diameters) · Default. The Durand formula above is used for all pipe diameters

Durand for pipes ≤200 mm, Kaev formula for >200 mm · Pipe sections with an inner diameter not greater than 200 mm still use Durand; sections greater than 200 mm switch to the Kaev formula

Kaev formula:

V_L = 1.04 × D^0.3 × (S − 1)^0.75 × ln(d50 / 16) × [ln(60 / Cv)]^0.13

where D is the pipe inner diameter (m), d50 is in µm and Cv is in %.

Applicable range: the Kaev formula requires d50 > 16 µm and Cv < 60% (otherwise the logarithm term is not greater than 0 and the formula has no meaning); if these are not met, that pipe section automatically uses the Durand formula.

Effect on results: this page shows results for a 100 mm reference pipe diameter, where both methods give the same result. With Kaev selected, the settling velocity of the suction and discharge pipe sections with an inner diameter greater than 200 mm on the “2 Head Details” page, the suction and discharge pipe velocity checks in “Select Assist”, and the settling judgment in duty simulation are all calculated with the Kaev formula. The selected method is saved with the plan and written into the selection report.

Worked example: D = 0.3 m, S = 2.65, d50 = 100 µm, Cv = 20%: V_L = 1.04 × 0.3^0.3 × 1.65^0.75 × ln(6.25) × (ln 3)^0.13 ≈ 1.04 × 0.697 × 1.456 × 1.833 × 1.012 ≈ 1.96 m/s.

Input checks and messages

Checks related to this step

The following items in the “Select Assist” panel are determined mainly by the inputs on this page:

Check · Message on failure · Action

Flow (Q) · Invalid flow rate. Please check flow rate · Enter a flow greater than 0; with Use Range, complete the min/max flow

Sm, Sw, Cw, Cv · Please check mixture properties S, Sm, Cw & Cv / Sw is out of range. Specify Sw between 1.0 and 1.4 · Complete the two known quantities; Sw must be 1.0–1.4

Mass Flow Rate · Invalid Mass Flow Rate. Check mass flow rate and d50 · Check flow, Sm, Cw and d50

Temperature · Check temperature · The temperature must not be below 0 °C

When the slurry type is “Water”, “Sm, Sw, Cw, Cv” shows “Water conditions” and passes. For full descriptions of each check, see Select Assist (Engineering checks).

Error confirmation before searching

When you click “Search” on the “Curve Selection” page and any of the flow, mixture, mass flow, head or temperature checks has failed, the message “There is at least one error in the inputed values (visible in the panel "Select Assist" in the dashboard). Do you want to execute the search ?” appears. Choose “Yes” to search anyway, or “No” to go back and correct the inputs.

Search again after changes

After a search, if you go back to an earlier step and change any of the following, the previous search results and selected curve are cleared when you return to “4 Curve Selection”, and you need to search again: flow Q, slurry head (and its Calculate/Define mode), pump type, pump system (single/multistage, series/parallel, number of pumps), duty mode, min/max flow, min/max head, slurry type, known slurry condition and flow condition, solids SG S, slurry SG Sm, concentration Cw/Cv, liquid SG Sw, particle size d50, fines content, temperature, froth volume factor, solids mass flow, HR/ER calculation method and custom HR/ER.

When a curve is selected, the system automatically replaces “WB Slurry Based” with “WB Standard”; this automatic switch does not count as a change and does not clear the results.

Fields by Slurry Type

Field / section · Single Solid · Water · Non-Newtonian · Froth · Two Solid Mix · Coal Mixture

Use Range · Available · Available · Not available · Not available · Not available · Not available

Known flow condition / known slurry condition · Shown · Hidden · Shown · Shown · Hidden · Shown

Liquid SG Sw · Editable · Hidden · Editable · Editable · Grayed out · Editable

Particle size d50 · Editable · Hidden · Grayed out · Editable · Grayed out · Editable (not used in calculations)

Particle Properties Lookup · Available · Hidden · Available · Available · Grayed out · Available

Slurry Properties box · Shown · Hidden · Shown · Shown · Shown (not used in calculations) · Shown (not used in calculations)

Optional particle details · Shown · Hidden · Shown · Shown · Shown · Shown

Specific section · None · None · Non-Newtonian · Froth · Two Solid Mixture · Coal Mixture

HR/ER source · Selected method · Fixed at 1 · Non-Newtonian method · Froth method · Preset values · Coal Mixture section

Common mistakes

Solids SG S left at the default 1 and weight concentration Cw left at the default 0, so the mixture check fails or HR/ER are always 1.

d50 left at the default 1 µm, so HR/ER are overestimated and the settling velocity is underestimated.

FVF not set for froth, so the flow is not scaled up and the derating is too small.

Sw entered as the slurry SG (e.g. 1.3 or more); it should be the SG of the liquid phase.

For the Coal Mixture type, only Q under “Mixture Properties” is entered, without the total slurry flow and coal feed rate in “Coal Mixture”, so Cw and Sm cannot be calculated.