Bearing Life, Critical Speed and Flange Load
This chapter covers the two tabs that appear from step 4 onward, below the content of the current step: “Bearing Life” for horizontal pumps (“Critical Speed” for vertical and submersible pumps) and “Flange Load”. They appear only after a curve has been selected. Based on the step 5 configuration, they calculate bearing L10 life, shaft stress and critical speed, and list the allowable loads on the pump's inlet and outlet flanges.
Tabs and when they appear
Tab · When shown
Bearing Life · Horizontal pumps. Data is available only after a curve is selected and you have entered step 5
Critical Speed · For vertical and submersible pumps, after you enter step 5 the “Bearing Life” tab is renamed “Critical Speed” and its content is replaced by the critical speed table
Flange Load · Shown from step 4 on; not shown when the selection is a private model or a public manufacturer curve
Tip: If the selected curve has not been purchased, the bearing life and critical speed tables are empty; after purchasing, search again and select the curve. Private models and public manufacturer curves have no frame or bearing data, so the tables are empty; see Filter Search 5: Configuration.
Motor parameters
Both tabs have a row of motor parameters at the top. They are used in the bearing life, shaft stress, critical speed and “Motor Power” checks.
Motor Power
Meaning: the rated power of the intended motor.
Unit: kW.
Default: empty.
Effect on calculations and results: used only for the “Motor Power” check in “Select Assist”: recommended motor power = slurry shaft power × safety factor, and the motor power must be greater than the recommended value. If it is not filled in, this check gives the warning “No motor selected”. See Select Assist for details.
Safety Factor
Meaning: the power margin factor for the motor power and the shaft calculations.
Default: 1.2.
Effect on calculations and results:
Recommended motor power = slurry shaft power × safety factor;
The shaft torque is calculated from “slurry shaft power × safety factor”, so a larger safety factor gives higher stresses at all three locations;
With a belt drive it also affects the belt design power.
Shaft torque T (N·mm) = 9.55 × 10⁶ × P (kW) / n (r/min)
P = slurry shaft power × safety factor
Worked example: slurry shaft power 32.7 kW and safety factor 1.2 give P ≈ 39.2 kW; at a pump speed of 1000 r/min, T ≈ 374 400 N·mm (about 374 N·m).
Drive Type
Options:
Option · Description
Direct · Default. The motor drives the pump directly through a coupling; the coupling end is calculated with the standard overhang distance
Belt · The motor drives the pump through V-belts. The system automatically selects the belt section, number of belts and pulleys from the design power and speed ratio, and includes the belt tension and pulley weight in the drive-end bearing loads and shaft stresses
Gearbox · The motor drives the pump through a gearbox and a coupling. Bearing loads and shaft stresses are calculated as for a direct drive (the pump end is still a coupling)
Motor with VFD · A variable-frequency motor drives the pump directly through a coupling, and its speed follows the pump speed. Bearing loads and shaft stresses are calculated as for a direct drive
Effect on calculations and results: with a belt drive, the belt tension is about 4T/D (T is the shaft torque, D the pulley diameter) and acts on the shaft extension; it usually lowers the drive-end bearing life and raises the drive-end stress. If no suitable pulley size can be found, the calculation is made without pulley loads: neither the belt tension and pulley weight nor the coupling weight are included, so the result may be more optimistic than with a direct drive; check it separately against the pulleys you actually use.
Motor RPM
Meaning: the rated speed of the motor.
Unit: r/min.
Default: 1450.
Effect on calculations and results: used only with a belt drive: together with the pump speed it determines the speed ratio (higher speed / lower speed), the service factor for speed-up drives and the pulley sizes. With a direct drive, a gearbox or a VFD motor, the pump speed equals the predicted speed, and the motor speed does not affect the calculations.
Bearing Life table
The “Bearing Life” table for horizontal pumps lists all frame/bearing assembly combinations available for the selected curve and impeller; each combination takes one row per pump (stage), so they can be compared side by side.
Stage
Meaning: for several pumps in series, which pump (1, 2, …) the row refers to; for a single stage there is only 1.
Effect on calculations and results: in series, the later stages have a higher inlet pressure, so a larger axial force acts on the shaft sleeve; the bearing life of later stages is therefore usually shorter.
Frame (column)
The frame model.
Assembly
The bearing assembly part number.
DE L10 Life
Meaning: the basic rating life L10 of the drive-end (Drive End, DE, motor side) bearing, i.e. the operating hours that 90% of a batch of identical bearings will reach.
Unit: h (hours).
Calculation:
L10h = 10⁶ / (60 × n) × ( C / (fa × P) )^p
n: pump speed (predicted speed; multiplied by 1.18 when “Use differential impeller” is ticked), r/min;
C: basic dynamic load rating of the bearing;
P: equivalent dynamic load, combined from the impeller radial hydraulic load, impeller weight, coupling or pulley load and axial force;
fa: application factor, 1.0 for water; for slurry it ranges from 1.0 to 1.6 depending on d50 relative to the pump inlet diameter, larger for coarser particles;
p: life exponent, 10/3 for roller bearings and 3 for ball bearings.
The exact way the loads are combined depends on the bearing type and arrangement and is determined automatically by the system from the selected bearing assembly.
Worked example (assumed data): C = 100 kN, P = 10 kN, fa = 1.2, n = 1450 r/min, p = 10/3:
C / (fa × P) = 100 / 12 ≈ 8.33
8.33^(10/3) ≈ 1174
L10h = 10⁶ / (60 × 1450) × 1174 ≈ 13 500 h
Display rules:
Display · Meaning
< 5000 · Life below 5000 h, red
A number from 5000 to 100000 · Calculated life, rounded to hundreds of hours, green
> 100000 · Over 100 000 h, green
No data · Cannot be calculated due to missing data, red
WE L10 Life
Meaning: the L10 life of the wet-end (Wet End, WE, impeller side) bearing.
Unit, calculation, display rules: same as DE L10 Life. The wet-end bearing carries both the impeller radial load and the axial force and is usually the end that governs life.
DE Stress
Meaning: the combined stress in the shaft section at the drive-end bearing as a percentage of the allowable stress.
Calculation: combined bending and torsion:
τ = 16 × T / (π × d³) torsional shear stress
σ = 32 × M / (π × d³) bending normal stress
τeq = √(τ² + σ² / 4)
Allowable stress = min(0.3 × yield strength, 0.18 × tensile strength)
Stress ratio = τeq / allowable stress × 100%
Worked example (assumed data): T = 374 400 N·mm, drive-end shaft diameter d = 60 mm, bending moment M = 300 000 N·mm; shaft material yield strength 550 MPa and tensile strength 750 MPa, so allowable stress = min(165, 135) = 135 MPa.
τ = 16 × 374400 / (π × 60³) ≈ 8.83 MPa
σ = 32 × 300000 / (π × 60³) ≈ 14.15 MPa
τeq = √(8.83² + 14.15² / 4) ≈ 11.3 MPa
Stress ratio = 11.3 / 135 ≈ 8%
Display rules: below 100% it shows “n %” (green); at or above 100% it shows “FAIL n %” (red); with missing data it shows “No data” (red).
WE Stress
The stress ratio in the shaft section at the wet-end bearing. In addition to torque, it includes the bending moment from the impeller radial load and the axial tension from the impeller thread. Display rules as above.
Thread Stress
The stress ratio in the root section of the impeller connecting thread, including torque, the axial force from tightening the impeller, and bending moment. Display rules as above.
Bearing Speed
Meaning: whether the pump speed is within the maximum speed allowed for the frame bearings, and the lubrication method.
Display rules:
Display · Meaning
Lubricate 'G' 3000rpm (green) · The pump speed does not exceed the frame's maximum bearing speed of 3000 r/min; the code in quotes is the lubrication method, G for grease and O for oil
G 3000rpm (red) · The pump speed exceeds the maximum bearing speed
Casing Pressure (column)
Meaning: whether rated pressure data exists for this pump with the current casing material and liner material combination.
Display · Meaning
OK (0 kPa - max n kPa) (green) · Rated pressure data is available; n is the upper limit of the rated working pressure
Insufficient data for casing pressure checks. (red) · No usable rated pressure data
Tip: This column only states the rated pressure limit; to see whether the working pressure exceeds it, look at the “Casing Pressure” check in “Select Assist”; see Select Assist.
Red highlighting rules
DE/WE L10 life below 5000 h;
Any stress at or above 100%, or no data;
Pump speed above the frame's maximum bearing speed;
No casing rated pressure data.
Cells meeting any of these conditions are shown in bold red.
Blue row
Rows with a light blue background belong to the frame currently selected in step 5 (all bearing assemblies and stages of that frame are highlighted). The other rows are other frames available for the same curve, for comparison: if the current frame has red cells while another frame is all green, you can go back to step 5 and switch to that frame.
Pulley selection for belt drive
When “Belt” is selected, the system automatically:
1. Calculates design power = shaft power × safety factor × belt service factor; when the pump speed is higher than the motor speed (speed-up drive), it is further multiplied by the speed-up service factor for the range the speed ratio falls in;
2. Determines the belt section from the design power and the higher speed (SPZ, SPA, SPB, SPC; the higher the power, the larger the section);
3. Selects the driver and driven pulley pitch diameters from the minimum pulley diameter and the speed ratio, and determines the number of belts;
4. Includes the pulley weight, the pulley face width (the overhang distance increases by half the face width) and the belt tension in the drive-end loads and stresses.
Critical Speed table
The shafts of vertical and submersible pumps are long cantilevers and must run clear of the first critical speed. The “Critical Speed” table has one row for each standard shaft depth.
Shaft Depth
Meaning: the length size of the vertical pump shaft (the greater the shaft depth, the longer the overhang and the lower the critical speed).
How to choose: click a row in the table to select that shaft depth; the row is shown with a light blue background. When you enter step 5, the first row is selected by default. The selected shaft depth is used for the “Critical Speed” check in “Select Assist”.
1st Range
Shows “N < x”, where x = 0.8 × NCr1, i.e. the first safe zone: the duty speed is below 80% of the first critical speed.
2nd Range
Shows “a < N < b”, where a = 1.2 × NCr1 and b = 1.6 × NCr1, i.e. the second safe zone: the duty speed is between 1.2 and 1.6 times the first critical speed (running above the critical speed).
Critical speed safe zone
The first critical speed is estimated from the static deflection of the shaft:
NCr1 (r/min) = (30 / π) × √(g / y)
g = 9810 mm/s², y is the static deflection of the shaft under its own weight and the impeller weight (mm)
Worked example (assumed data): y = 0.1 mm gives NCr1 = 9.549 × √98100 ≈ 2991 r/min.
Zone · Speed range · Conclusion
First safe zone · N < 2393 r/min (0.8 × NCr1) · Safe
Resonance zone · 2393–3589 r/min (0.8–1.2 × NCr1) · Not allowed
Second safe zone · 3589 < N ≤ 4786 r/min (1.2–1.6 × NCr1) · Safe
Overspeed zone · N > 4786 r/min (above 1.6 × NCr1) · Not allowed
A predicted speed of 1450 r/min falls in the first safe zone; a predicted speed of 3000 r/min falls in the resonance zone, so that shaft depth cannot be used.
Life and stress columns (Critical Speed table)
The meaning, calculation and display rules of the five columns “DE L10 Life”, “WE L10 Life”, “DE Stress”, “WE Stress” and “Thread Stress” are the same as in the bearing life table; for vertical pumps the stresses also include the shaft's own weight. The critical speed table has no “Stage”, “Frame”, “Bearing Speed” or “Casing Pressure” columns.
Why a row is red
A whole row shown in red means that shaft depth fails on speed or stiffness:
Resonance: the predicted speed falls between 0.8 and 1.2 × NCr1, or exceeds 1.6 × NCr1;
Deflection: the static deflection of the shaft exceeds 1/400 of the overhang length.
In addition, individual red cells indicate:
Life: DE or WE L10 life below 5000 h;
Stress: any stress at or above 100%.
The “Critical Speed” check in “Select Assist” requires the selected shaft depth to satisfy the speed safe zone, all three stresses below 100% and both bearing lives of at least 5000 h at the same time; if any one is not met, it shows a red cross.
Choosing the shaft depth
1. First rule out shaft depths whose whole row is red;
2. Among the remaining rows, choose a shaft depth whose life and stress values are all green;
3. As long as process requirements (liquid level, sump depth) are met, choose the shortest possible shaft depth: the critical speed is higher and the stresses are lower;
4. Click that row and confirm that “Critical Speed” in “Select Assist” changes to pass.
If no shaft depth passes, try a different shaft material, bearing assembly or pump size.
Flange Load
The “Flange Load” tab lists the piping loads (forces and moments) that the suction and discharge flanges of the selected pump may carry, for checking the piping design. The actual loads that the piping applies to the pump flanges should not exceed the values in the table.
Axis convention
z axis: along the axis of the suction flange (for horizontal end-suction pumps, the pump shaft direction);
y axis: along the axis of the discharge flange (vertical for top discharge);
x axis: the horizontal direction perpendicular to y and z.
The “Suction” and “Discharge” rows in the table are group headings in bold on a yellow background. Forces are in N and moments in Nm. Missing data is shown as “-”; the data of the selected pump is loaded only after you enter step 5, so “-” is shown in step 4.
Suction: Axial Load (Fz)
The force (tension or compression) along the axis of the suction flange, in N.
Suction: Force in x-y (Fxy)
The resultant shear force perpendicular to the suction axis, in the x-y plane, in N.
Fxy = √(Fx² + Fy²)
Worked example: if the piping applies Fx = 1500 N and Fy = 2000 N to the suction flange, then Fxy = 2500 N, which should not exceed the allowable value in the table.
Suction: Bending Moment (Mxy)
The resultant bending moment about the x and y axes, in Nm: Mxy = √(Mx² + My²).
Suction: Torsional Moment (Mz)
The torsional moment about the suction flange axis (z axis), in Nm.
Discharge: Axial Load (Fy)
The force along the axis of the discharge flange (y axis), in N.
Discharge: Force in x-z (Fxz)
The resultant shear force perpendicular to the discharge axis, in the x-z plane, in N: Fxz = √(Fx² + Fz²).
Discharge: Bending Moment (Mxz)
The resultant bending moment about the x and z axes, in Nm: Mxz = √(Mx² + Mz²).
Discharge: Torsional Moment (My)
The torsional moment about the discharge flange axis (y axis), in Nm.
FAQ
Bearing Life table is empty
No curve is selected, step 5 has not been entered, or the selected curve has not been purchased;
The speed cannot be predicted at the duty point (life is not calculated when the speed is 0);
The selected curve is a private model or a public manufacturer curve.
Critical Speed table is empty
For vertical and submersible pumps, once the impeller is selected in step 5, the frame and bearing assembly are selected automatically from the slurry shaft power and the critical speed table is calculated; the table refreshes automatically when you change the impeller, frame or bearing assembly. If it is still empty, usually the speed cannot be predicted at this duty point, or the impeller has no frame or bearing data.
How to increase bearing life
Switch to a frame with a higher power rating (bearings with a higher dynamic load rating); lower the speed (choose a larger pump size); change to a direct drive; or check whether d50 has been entered too high (which raises the application factor).