Private models
Private models let you enter your own pump performance data: after you enter a rated-speed performance table or a multi-speed test table, the system generates the same family of speed curves, iso-efficiency lines and iso-NPSHr lines as for catalog curves, and the curves are matched automatically against the duty in Data Search, Filter Search and duty simulation. Private curves are visible only to you (and to your teammates when you are in a team). Entry point: “My Private Models” in the left Workspace.
Requirements
Premium
Creating, editing, copying, previewing and bulk importing private curves require Premium membership (team members can also do this while their team is active). Regular users and users whose membership has expired can still view and delete existing curves and continue to use them in searches. See Membership and curve watermarks.
Quantity limits
Each account can have at most 200 private curves (only curves you created count); beyond that the message “At most 200 private curves” appears.
Team permissions
Team members need the “Private models” permission set to “Edit own” to create, import and modify their own private curves, and “Manage all” to modify and delete teammates' private curves. See Team Edition.
Private models list
The page title is “My Private Models”, and the subtitle explains what private curves are for. When there are no curves, “No private curves yet. Click "New private curve" and enter a rated-speed table or a multi-speed test table.” is shown. Double-click a row to view the curve.
New private curve (button)
Opens the create page. When a regular user clicks it, the message ““My Private Models” is a Premium feature” appears. Greyed out for team members whose “Private models” permission is “No access”.
Bulk import (button)
Opens the bulk import page, where you can import multiple curves at once from Excel / CSV; see Bulk import. When a regular user clicks it, the message ““Bulk import” is a Premium feature” appears. Greyed out for team members whose “Private models” permission is “No access”.
Impeller quick estimate (button)
Opens the impeller quick estimate, which estimates a curve from the impeller geometry and can save it as a private model; see Impeller quick estimate. When a regular user clicks it, the message ““Impeller quick estimate” is a Premium feature” appears.
Membership notice
When regular users and users whose membership has expired open the list page, the message box ““My Private Models” is a Premium feature” and a “Get Premium” button are shown above the buttons; the list is displayed as usual.
Range Chart (button)
Opens the Range Chart; see Range Chart in this chapter. The button is disabled when there are no private curves.
Refresh
Reloads the list.
Mine / Whole team (private models)
Shown when sharing within a team: “Mine” lists only your own curves; “Whole team” also includes your teammates' curves.
Model (column)
The pump model; click the column header to sort.
Size (column)
The pump size; click the column header to sort.
Curve name (column)
The curve name; empty if not entered.
Created by (private models list)
Shown when sharing within a team: the member who entered the curve; your own entries are shown in blue.
Input (column)
“Rated-speed table” or “Multi-speed test table”.
Alignment (column)
Horizontal, Vertical or Submersible.
Speed r/min (column)
The speed range covered by the curve, “min–max”, with the rated speed in parentheses.
BEP (column)
The best efficiency point at rated speed, “flow m³/h · head m · efficiency %”. Whatever units were used for entry, this column is always shown in m³/h and m.
Updated (column)
The time of the last save.
View curve
Opens the curve page of the curve in a new window, in the same way as for catalog curves; see Curve Viewer.
Edit (actions)
Opens the edit page. Greyed out for non-members or without modify permission.
Duty Simulation (private models list)
Opens the duty simulation with the best efficiency point of the curve at rated speed as the design point (clear water, no piping entered). Greyed out for non-members.
Duplicate
Copies the curve as a new curve under your name, with “ (2)” appended to the curve name (if the curve name is empty, the size name with “ (2)” is used); the message “Duplicated” appears. For a teammate's curve the button shows “Copy to mine”, and the copy keeps the original name. Greyed out for non-members or without create permission. If you already have 200 private curves, the message “At most 200 private curves” appears; without team permission, or when your membership has expired, a corresponding message is shown as well.
Delete (actions)
After you confirm “Delete private curve "name"? This cannot be undone.”, the curve is deleted and the message “Deleted” appears. Deleting does not require membership; it is greyed out without modify permission (a teammate's curve and the “Private models” permission is not “Manage all”, or when the team is in its grace period). Saved selections and project selections that reference the curve will no longer be able to open it.
If the deletion fails, a message gives the reason: if the curve has already been deleted, “Not found — it may have been deleted” is shown and the list is refreshed; without team permission, “You don't have team permission for this. Please contact the team owner”; if the team has expired, “The team has expired; shared data is read-only”; if your session has expired, “Your session has expired. Please sign in again”.
Create and edit page
Enter the data on the left of the page; the curve preview on the right updates in real time. The title is “New private curve” or “Edit private curve”; “Back to list” at the top right returns to the private models list without saving the current changes.
Auto-saved draft
Once you change any input, the system automatically saves what you have entered as a draft in the current browser, separate for each account; the new-curve page and the edit page of each curve each have their own draft.
When you open the same page again (a new curve, or editing the same curve), the draft is restored automatically, and the message “Your unfinished input from last time has been restored (saved time) · Clear” is shown. Click “Clear” to discard the draft: the new-curve page returns to a blank form, and the edit page returns to the curve's saved content.
The draft is cleared automatically after a successful save.
The draft is only in the current browser; it is not carried over when you change browser or computer.
Leave page reminder
When there are unsaved changes, clicking “Back to list” or switching to another page brings up a “Leave page” confirmation: “You have unsaved changes (saved as a draft that will be restored next time you open this page). Leave anyway?” Click “Leave” to continue, or “Stay on page” to cancel. When you close the tab or refresh the page, the browser also shows a leave confirmation.
Basic information
Pump model
Meaning: the model name of the private curve; it appears in the “Pump Model” drop-down of Data Search and Filter Search (in the “Private models” group).
Values / rules: required, up to 64 characters. While you type, your existing private model names are suggested; if several curves use the same model name, they are grouped under the same model.
Pump size
Values / rules: required, up to 64 characters. Shown in the “Pump” column of search results and in the curve title.
Curve name
Values / rules: optional, up to 64 characters. Used to distinguish different curves of the same size (for example, different impellers).
Alignment
Values: Horizontal, Vertical, Submersible; default Horizontal.
Effect: determines under which category the curve falls in the Data Search “Type” and the Filter Search pump type; the NPSHa check is performed only for horizontal curves.
Units
Values: “L/s, m”, “m³/min, m”, “m³/h, m” (default), “USGPM, ft”.
Effect: the flow, head and NPSHr in the performance point table, and the values of the iso-NPSHr lines, are all interpreted in the selected units. Speed is always in r/min, and the construction data are always metric.
Note: changing the units does not convert numbers already entered.
Input
The two buttons at the top of the input card switch the input mode. The data of the two modes are kept separately; switching does not clear what you have entered in the other mode, but only the currently selected mode is used when saving.
Rated-speed table
Hint: “Enter 5–50 performance points at rated speed; speed lines, iso-efficiency and NPSHr lines are generated by the affinity laws.” Suitable when you only have one test curve at rated speed.
Multi-speed test table
Hint: “Enter 2–12 measured lines at different speeds (3–50 points each). Interpolation only covers the measured speed range, so include the lowest and highest speed.” Suitable when you have variable-speed test data; the result is closer to the measurements.
Import from PDF
The "Import from PDF" button at the top right of the entry card reads a performance curve PDF exported from a manufacturer's selection software, recognizes the speed, efficiency and NPSH lines, and after you confirm fills them into the multi-speed test table, so you don't have to copy points by hand.
Supported files
Vector PDFs: PDFs exported or saved from selection software, Word, Excel and so on, whose lines stay sharp when you zoom in.
Scanned or photographed PDFs (each page is one image) are not supported. You will see "No vector curves found"; please enter the data manually.
Files up to 5MB. For multi-page PDFs you can choose which page to recognize.
The file is used only for recognition and is not stored on the platform.
Note: recognition cannot be 100% accurate. Check each line’s type and value against the original before filling in, then check the curve preview.
Recognition result
The left side redraws the curves on the original coordinates, colored by type: speed lines blue, efficiency lines green, NPSH lines yellow, BEP line red, dashed for "Ignore". The right side lists each line with its type and value (speed r/min, efficiency %, NPSH value). The counts are shown above, for example "10 speed lines · 8 efficiency lines · 4 NPSH lines".
Review and correct
Click a line in the chart or a row on the right; both are highlighted so you can compare.
Change the type or value if it is wrong; set unwanted lines to "Ignore".
Lines without a value are reported above as "N lines have no value yet" and their value box has an orange border.
Flow unit, head unit
Detected from the axis titles on the chart (m³/h, L/s, m³/min, USGPM; m, ft). Change them if the detection is wrong. When filling in the table, values are converted to m³/h and m.
Ask Xiaorui
If the automatic result is uncertain, click “Ask Xiaorui”. Xiaorui, the recognition assistant, uses the line positions and chart text to complete lines that have no matching label or no value; lines already identified from the chart labels are left unchanged. Rows Xiaorui completed are marked “Xiaorui”; please review them.
Up to 30 times per person per day.
Fill in table
After you click "Fill in table":
The entry switches to the multi-speed test table, one group per speed line, with points taken from the original curves. Efficiency and NPSHr come from where the efficiency and NPSH lines cross each speed line; the best efficiency point is estimated where the BEP line crosses the speed line.
The efficiency and NPSH levels of the original chart are filled into Advanced settings, so the generated curve matches the original.
The highest-speed line with enough efficiency points is set as the rated line.
If only one speed line is recognized, it is filled in as a rated speed table.
If the table already has data you are asked to confirm the replacement; the model, size, installation and structural parameters you entered are kept.
The impeller diameter, number of vanes, minimum passage (MAX. SOLIDS etc.) and pump size (e.g. 12 x 10 inches converted to inlet/outlet size) on the chart are read as well; the impeller type (e.g. “5 VANE Closed”), seal type and frame code shown on the chart are read too. When ticked, they fill only the empty fields in Structural parameters; the frame code is filled into the first row only when the frame table is empty, and the rated power must be entered by hand.
Then review the preview as usual, enter the model and size, and save.
Recognition messages
Message · Meaning
No vector curves found · The file is a scan or an image; enter the data manually
No axis scales recognized · This page is not a performance curve chart, or the scales are not text; try another page of a multi-page PDF
This PDF is encrypted · Remove the password protection before uploading
No efficiency lines · The generated curve has no efficiency
More than 12 speed lines · 12 are kept evenly
Highest and lowest speeds differ by more than 5× · The lowest lines are removed
If recognition is not accurate
Situation · What to do
A line has the wrong type (e.g. the BEP line taken as an efficiency line) · Correct the type of that row on the right; set unwanted lines to “Ignore”. Lines of one kind usually share a color; compare the color swatch at the start of each row
A value is wrong or empty (orange-bordered value box) · Click the line in the chart to find its row and enter the speed, efficiency or NPSH value from the chart label
Not sure which lines were missed · Click “Ask Xiaorui” to complete lines without a matching label or value, then review the rows marked “Xiaorui”
A speed line is missing · Fill in the table first, then click “Add speed line” in the “Multi-speed test table” and enter that line manually
Wrong flow or head unit · Change “Flow unit” / “Head unit” at the top of the recognition window before filling in
A multi-page PDF read the wrong page · Click “Choose another file”, pick the file again, select the correct page number and click “Recognize this page”
“No vector curves found” or “No axis scales recognized” · The file is a scan or an image, or this page is not a performance curve chart. Enter the data manually, or paste it from Excel in one go with “Paste whole table (with speed column)”
The preview differs from the original after filling in · Edit or delete points directly in the performance point table, or run “Import from PDF” again and fill in once more
Speed (Rated-speed table)
Rated speed
Meaning: the speed to which the performance point table applies; it is also the speed shown in bold on the curve page and the speed at which the best efficiency point is taken.
Values / rules: 100–10000 r/min, default 1480; must lie between the minimum and maximum speed.
Min speed
Meaning: the lowest speed of the generated curve family; searches and simulations will not give results below this speed.
Values / rules: 100–10000 r/min, default 800; must be less than the maximum speed.
Max speed
Values / rules: 100–10000 r/min, default 1800; cannot exceed 5 times the minimum speed.
Speed line step
Meaning: the speed difference between two adjacent speed lines on the curve chart.
Values / rules: leave empty for “Auto”: a value is chosen from 10, 20, 25, 50, 100, 150, 200, 250, 500, 1000, 2000 r/min according to the speed range, so that there are about 12 speed lines or fewer. When entered manually, there can be at most 100 speed lines, and “number of speed lines × number of points” cannot exceed 450.
How the speed curves are generated
Based on the performance points at rated speed n₀, values are converted to any speed n by the affinity laws:
Q = Q₀ × (n / n₀)
H = H₀ × (n / n₀)²
NPSHr = NPSHr₀ × (n / n₀)²
η(n) = 100 − (100 − η₀) × (n₀ / n)^m
where m is the “Low-speed efficiency exponent m”. Head lines are displayed after a 4th-order polynomial fit; a note is given if the fit deviates significantly from the entered points.
Speed lines (Multi-speed test table)
Speed line n
Each speed line has its own box, whose header contains:
Speed: the measured speed of this line, 100–10000 r/min.
Rated: a radio button that marks the rated-speed line. The rated line is the main curve; the best efficiency point is taken from it, and it must have at least 3 efficiency values greater than 0.
✕: deletes the speed line; it cannot be deleted when only 2 lines remain.
Inside the box is the performance point table for that speed, 3–50 points per line.
Add speed line
Adds an empty speed line at the end, up to 12 lines.
Paste whole table (with speed column)
Click to open the paste window, with the hint: “Paste a table copied from Excel with five columns: speed, flow, head, efficiency, NPSHr. Rows are split into lines by speed.”
The column order must be: speed, flow, head, efficiency, NPSHr; efficiency and NPSHr can be empty.
Rows whose first or second column is not a number (such as header rows) are skipped automatically.
After you click “OK”, all existing speed lines are replaced, arranged from the highest speed to the lowest, and the line with the highest speed is automatically set as the rated line.
Multi-speed rules
2–12 speed lines, with the speeds of the lines differing by at least 1%.
The maximum speed cannot exceed 5 times the minimum speed.
The curve covers only the measured range from the lowest to the highest speed; between adjacent speed lines, values are interpolated using the affinity relationships. Be sure to include speed lines at the lowest and highest speeds of the range you will use.
Points
Points table columns
Column · Meaning · Rules
# · Row number · —
Flow · Unit follows “Units” · Required; cannot be negative; can be 0 (shut-off point)
Head · Unit follows “Units” · Required; must be greater than 0
Eff % · Efficiency at the point · Optional; greater than 0 and at most 100; 0 is allowed only at the shut-off point with zero flow
NPSHr · Net positive suction head required, in the same unit as head · Optional; if entered, must be greater than 0
✕ · Deletes the row · Cannot be deleted when only 1 row remains
The points can be in any order; they are sorted by increasing flow when the curve is generated. The same table cannot contain two identical flow values.
Add row
Adds an empty row at the end of the table, up to 50 rows.
Clear
Clears the whole table, leaving one empty row.
Paste from Excel
Hint: “Paste directly from Excel (flow, head, efficiency, NPSHr)”.
When you paste multi-row (or tab-separated) content into any cell of the table, the whole table is replaced by the pasted data, up to 50 rows.
The column order is flow, head, efficiency, NPSHr; missing columns are left empty.
Rows whose first cell is not a number (such as header rows) are skipped automatically.
Cells can be separated by tabs, semicolons, spaces or commas; thousands separators (e.g. 1,250.5) and decimal commas (e.g. 12,5) are recognized.
If you paste a single value, it is treated as normal input.
Minimum points for efficiency and NPSHr
The rated-speed table (or the rated line of a multi-speed table) must have at least 3 efficiency values greater than 0.
At least 2 NPSHr values are needed to generate NPSHr curves; if you enter no NPSHr, the curve has no NPSHr data, and when NPSHa is entered in a search it is evaluated as “Unable to predict NPSHr”.
Incomplete rows
Rows in which only the flow or only the head is filled in (or only the efficiency or NPSHr) are not used for generation, and the preview area shows an orange “Incomplete rows” note: “Row(s) N, M are only partly filled (both flow and head are required) and are ignored” (for multi-speed tables, prefixed with “Speed line n:”).
Note: “Row N” in errors and notes counts only the complete rows used for generation. When the table contains incomplete rows, the row number may not match the # on the left of the table; complete or delete the incomplete rows first.
Advanced
Click “Advanced” to expand.
Low-speed efficiency exponent m
Meaning: the correction exponent for efficiency when the speed differs from the rated speed. Real pumps lose efficiency at low speed, and the pure affinity laws (m = 0) overestimate the efficiency at low speed.
Values / rules: 0–0.3, step 0.05, default 0.15. Shown and used only in the “Rated-speed table” mode.
Formula:
η(n) = 100 − (100 − η₀) × (n₀ / n)^m
Page hint: “0 = pure affinity; 0.1–0.2 matched real slurry pumps best, default 0.15.”
Example (hypothetical numbers): at the rated 1480 r/min a point has efficiency η₀ = 78%, m = 0.15; converted to n = 1000 r/min: (1480/1000)^0.15 ≈ 1.061, η = 100 − 22 × 1.061 ≈ 76.7%.
Iso-efficiency lines (%)
Meaning: the efficiency values for which iso-efficiency lines are drawn on the curve chart.
Values / rules: leave empty for automatic; when entered manually, separate the values with commas (full-width or half-width), semicolons or spaces, e.g. “60, 65, 70, 75”. Only values greater than 0 and below the maximum efficiency are kept; duplicates are removed automatically.
Automatic rule: values are taken at even intervals of 1, 2, 2.5, 5 or 10 percentage points, from the largest of “the lowest entered efficiency, the maximum efficiency − 40, and 10” up to the maximum efficiency, with at most 8 lines.
NPSHr lines
Meaning: the NPSHr values for which iso-NPSHr lines are drawn on the curve chart; the unit follows “Units” (m or ft is shown after the label).
Values / rules: leave empty for automatic; manual entry follows the same rules as iso-efficiency lines, and only values within the data range are kept.
Automatic rule: values are taken at even intervals between the minimum and maximum NPSHr, with at most 10 lines.
Construction data (optional)
Click “Construction data (optional)” to expand. Hint: “Used by selection checks: tip speed needs impeller diameter and max tip speed, casing pressure needs the rated working pressure; otherwise those checks show "no data".”
Impeller diameter mm
Used to calculate the tip speed (tip speed = π × impeller diameter × speed ÷ 60).
Vane diameter mm
Used by the “WB Pump Based” HR/ER method; if empty, the impeller diameter is used. If both are empty, Filter Search cannot use the pump-type methods.
Max tip speed m/s
The limit for the tip speed check, used together with the impeller diameter.
Impeller material
Text, up to 64 characters, for record and display only.
Casing working pressure kPa
The limit for the casing pressure check.
Casing material
Text, up to 64 characters, for record and display only.
Suction mm
The pump suction size, shown in the specifications.
Discharge mm
The pump discharge size; used for the efficiency correction when a mechanical seal is selected.
Min passage mm
The largest particle size that can pass through the pump, shown in the specifications.
Impeller vanes
An integer, shown in the specifications.
Impeller type
Text, e.g. Closed or Open; shown in the spec panel of the curve page as “Impeller / Type”.
Seal type
Text. Entering Gland, Centrifugal or Mechanical is shown as “Gland Sealed Pump” and similar on the curve page; other wording (e.g. “packed seal”) is shown as entered. This is for record and display only; the seal derating in the filter is still calculated from the “Seal Type” chosen in step 5.
Nameplate spec tables
Below “Construction data (optional)” there are three small tables. Click “+ Add row” to add a row, and “Delete” at the right of a row to remove it; each table holds at most 12 rows. Rows that are completely empty are removed automatically on save. What you enter is shown in the spec panel of the curve page, row by row, in the same way as the spec panel of catalog curves.
Table · First column · Second column · Purpose
Impeller part no / material · Part no · Material · Shown under “Impeller”
Frames · Frame (e.g. G, GG) · Rating kW · Shown under “Frame (Rating - KW)”; used by the “Frame Power” check in the filter
Liners · Liner material (e.g. Polymer, Metal) · Max speed r/min · Shown under “Liner (Norm Max r/min)”; used by the “Liner Speed” check in the filter
One model can have several frames or several liner types; enter one row for each. If the frame rating or the liner max speed is left blank, “-” is shown and the matching filter check does not appear. For the check rules see Select Assist.
Data for advanced filter calculations (optional)
Click “Data for advanced filter calculations (optional)” to expand. This data is used in step 5 of the filter for bearing life, critical speed, centrifugal seal pressure, flange loads and casing pressure, with the same calculation as built-in curves. Anything left empty shows “N/A”. All values are metric.
Impeller mass data
Item · Unit · Purpose
Impeller mass · kg · Bearing load, shaft stress, critical speed
Impeller width · mm · Radial force
CG distance d · mm · Distance from the impeller's centre of gravity to its back face; bearing load and critical speed
Agitator mass · kg · Fill in for a vertical pump with an agitator
Impeller has back vanes · Tick box · Affects axial force
Allowable flange loads (forces N, moments N·m)
Eight values: suction Fz, Fxy (N), Mxy, Mz (N·m); discharge Fy, Fxy (N), Mxy, My (N·m). If any one of them is entered, the “Flange Load” tab is shown in step 5 of the filter.
Casing pressure table
Each row: casing material, liner material (optional), rated working pressure kPa. Once this table is filled in, the filter's “Casing Pressure” check lists every row and passes if any one row is sufficient; the “Casing pressure” column of the bearing life table takes the highest rating. If this table is left empty, the single “Casing working pressure” under “Construction data” is still used.
Expellers (centrifugal seal)
One card per expeller: part no, whether it is Hi-Seal (high-seal expeller), and 8 dimensions (mm): expeller OD, expeller ID, expeller ring ID, back vane OD, back vane ID, back vane height (outer), back vane height (inner) and back vane clearance. All 8 dimensions must be filled in before the seal pressure can be calculated; if any is missing, the card shows “Dimensions incomplete”.
In step 5 of the filter, after choosing centrifugal seal as the “Seal Type”, you can choose between “Std Expeller” and “Hi-Seal”; the “Seal Pressure” check and the “Expeller Curve” are calculated from the dimensions entered here.
Bearing assemblies (frame + shaft + bearings)
One card per bearing assembly on a frame. Click “+ Add bearing assembly” to add one; “Copy” duplicates the current card so you can edit the copy. Each card contains:
Part · Content
Assembly code, frame code · Choose the frame code from the “Frames” table above (or type a new one); one frame can have several assemblies
Frame and lubrication · Lubrication (Grease G / Oil O), grease type (EP or blank), max bearing speed r/min, coupling/pulley mass kg
Shaft dimensions mm (grey = optional) · Required: a, b, ds1, ds2, dss; optional (grey): e, dbs, do, dc, dtd, lth. For vertical cantilever pumps enter a as a negative value (cantilever length = shaft depth + a), on the same basis as the built-in data
Impeller thread mm · Nominal dia, minor dia, pitch (effective) dia, pitch; can be filled in automatically with “Pick from standard data”
Shaft material · Tensile strength, yield strength MPa, density kg/m³, Young’s modulus MPa; can be filled in automatically with “Pick from standard data”
Wet-end (impeller side) bearing and dry-end (drive side) bearing · Type, qty, dynamic rating C90 N, K factor, bore, OD mm, e', Y1, Y2; can be filled in automatically with “Pick from standard data”
At the bottom of each card:
“Missing: …” lists the required items not yet entered; until they are, bearing life and critical speed cannot be calculated for this assembly.
“Wet end … / dry end … is not a supported combination” means bearing life uses a calculation method chosen by the combination of wet-end and dry-end bearing types and quantities; unsupported combinations show “-”. Click “Supported bearing combinations” next to the note to see all supported combinations.
“Complete” means the data is ready, and bearing life, shaft stress and critical speed can be calculated.
When this private model is selected in step 5 of the filter, the “Private model parameters” card shows “Frame” and “Bearing Assembly” dropdowns. The frame is chosen automatically as the smallest frame whose rating covers the slurry shaft power (as for built-in curves), and the bearing assembly is the first one on that frame. The bearing life table (horizontal pumps) or critical speed table (vertical pumps) lists all assemblies. See Filter Search 5: Configuration.
Preview and save
Auto preview
When there is enough data (at least 5 complete points for a rated-speed table; at least 2 lines with at least 3 complete points each for a multi-speed table), a preview is generated automatically about 0.8 seconds after each change. The preview area embeds the full curve page, where you can drag readings and zoom, exactly as on the final curve. When there is not enough data, “The preview is generated automatically once data is entered” is shown.
Preview
Generates a preview immediately; while generating, the button shows “Generating…”.
Summary
When the preview succeeds, the following is shown: “BEP Q m³/h · H m · E%, speed min–max r/min (rated n), N speed lines”. In the summary, flow is always shown in m³/h and head in m.
Open in new window
Opens the preview curve full size in a new window.
Save
Click “Save”: after the checks pass, the curve is saved, the message “Saved” appears and you return to the list. If there are errors, the message “Please fix” appears, the errors are listed at the top of the preview area, and nothing is saved. A newly saved curve can be used in searches immediately.
Other messages when saving is not possible:
Message · Reason
“New private curve” is a Premium feature (“Edit private curve” when editing) · Your membership has expired; see Membership and curve watermarks
You don't have team permission for this. Please contact the team owner · The team member lacks permission to create or modify private models
The team has expired; shared data is read-only · The team is in its grace period; teammates' curves cannot be modified
At most 200 private curves · The quantity limit has been reached
Not found — it may have been deleted · The curve has been deleted elsewhere
Save conflicts
When the same curve is edited in two windows at the same time (or by two teammates), the one who saves later gets a “Version conflict” dialog: “This curve was changed and saved while you were editing it (perhaps in another window or by a team member). Your input is still on the page. Choose:”
Button · Action
“Overwrite with my version” · Saves the content currently on your page, overwriting the version saved elsewhere
“Discard my changes” · Discards your changes; the page loads the latest version of the curve and shows “The latest version has been loaded”, so you can modify it again on that basis
Close the dialog (✕ at the top right) · Does not save; stay on the page and keep editing; your input is not lost
Note: choosing “Overwrite with my version” will discard the changes made elsewhere. When working in a team, if you are not sure what the other person changed, first open the curve in another window to check.
Please fix (errors)
The red “Please fix” box at the top of the preview area lists the errors that must be corrected, in the format “Field: error”. Field names include Points, Pump model, Pump size, Curve name, Rated speed, Min speed, Max speed, Speed line step, Speed lines, Units, Alignment, Input and Low-speed exponent, as well as “Speed line n” and “Speed line n Speed”.
Required
The pump model or pump size is empty. Fill it in.
At most 64 characters
The pump model, pump size or curve name is longer than 64 characters; shorten it.
Invalid units
The units are not one of the four options. Select the units again.
Invalid alignment
Select the alignment again.
Invalid input mode
Click the input mode again.
Must be between 0 and 0.3
The low-speed efficiency exponent m is out of range; change it to a value between 0 and 0.3.
N–M points required (now K)
Too few or too many complete points: a rated-speed table needs 5–50 points, and each line of a multi-speed table needs 3–50 points. Add or remove data points; note that half-filled rows are not counted.
Duplicate flow values
Two points in the table have the same flow. Delete or change one of them.
Row N: invalid number
The flow or head in this row is not a valid number. Check whether text or special characters have slipped in.
Row N: flow cannot be negative
The flow must be greater than or equal to 0.
Row N: head must be > 0
The head must be positive; enter the shut-off head at the shut-off point too.
Row N: efficiency must be above 0 and at most 100 (0 is allowed only at shut-off)
The efficiency is outside 0–100, or 0 was entered at a point where the flow is not 0. If you do not know the efficiency, leave it empty.
Row N: NPSHr must be > 0
NPSHr was entered as 0 or a negative value. Leave it empty if you have no data.
Row N: flow too large
After conversion the flow exceeds 20000 L/s (72000 m³/h). Check whether the wrong units are selected.
Speed must be 100–10000 r/min
The rated, minimum or maximum speed, or the speed of a speed line, is out of range.
Need min < max and rated between them
Adjust the relationship between the three speeds.
Max/min speed ratio cannot exceed 5
Narrow the speed range.
Too many speed lines (max 100); increase the step
The speed line step is too small; increase it, or leave it empty to use “Auto”.
Too many speed lines × points
The full message is “Too many speed lines × points (N × M > 450); increase the step or use fewer points”. Increase the speed line step, leave it empty to use “Auto”, or reduce the number of performance points.
At least 3 efficiency values required
Fewer than 3 efficiency values greater than 0 in the rated-speed table (or the rated-speed line). Add efficiency data.
2–12 speed lines required
The number of speed lines in the multi-speed table is wrong.
Line speeds must differ by at least 1%
Two speed lines have speeds that are too close (or identical). Merge them into one, or change the speed.
Generated curve failed self-check
The full message is “Generated curve failed self-check (item); please check the data”. Abnormally shaped data prevented a usable curve from being generated (for example, an abnormal head curve, too few efficiency points or too narrow a spread). Check the data and, if necessary, add data points or extend the flow range.
Curve generation failed
The full message is “Curve generation failed: reason”. An exception occurred during generation; check the data and try again. If it still fails, contact customer support.
At most 200 private curves
The quantity limit has been reached; delete curves you no longer use before creating or copying new ones.
Input too large
The input exceeds the storage limit; reduce the number of data points or speed lines.
Modified in another window; please reload before saving
The curve has been changed elsewhere. When you save on the edit page in this situation, a “Version conflict” dialog appears, where you can choose to overwrite or load the latest version; see Save conflicts above.
Notes (saving still allowed)
The orange “Notes (saving still allowed)” box in the preview area lists suspicious data; you can save, but it is advisable to check it.
Row N: head is more than 5% above the previous point (drooping curve?)
After sorting by flow, the head at this point is more than 5% higher than at the previous point; the curve may have a hump, or the data may have been entered incorrectly. Curves with a hump may be unstable in parallel operation and at low flow.
Peak efficiency is at maximum flow; right-hand iso-efficiency branches will be missing
The entered efficiency is still rising at the maximum flow, so there is no data to the right of the best efficiency point; the right-hand branches of the iso-efficiency lines cannot be drawn, and the best efficiency point may be underestimated. Add data at high flow if possible.
Row N: efficiency differs from the previous point by more than 15 points
The efficiency jumps too much between adjacent points; check for entry errors (for example, the position of the decimal point).
NPSHr does not increase at high flow
The NPSHr of the last point is smaller than that of the second-to-last point, which is contrary to the usual pattern; please check.
Max deviation of the 4th-order fit from the entered head N%
The head lines of the rated-speed table are displayed after a 4th-order polynomial fit, and the maximum deviation from the entered points exceeds 2%. This happens when the curve shape is complex or there are individual outliers; check the outliers or add more points.
Interpolated speed at BEP differs from rated speed
The full message is “Interpolated speed X at BEP differs from rated speed Y”. The speed obtained by back-calculation at the best efficiency point deviates from the rated speed by more than 2% (1% for multi-speed tables), meaning the data are not consistent enough near the rated point; the predicted speed returned by searches may be off.
At least 2 NPSHr values are needed to build NPSHr curves
Only 1 NPSHr value was entered, so no NPSHr curve can be generated. Add NPSHr data or leave all NPSHr cells empty.
Using private curves in selection
In Data Search
The “Private models” group of the “Pump Model” drop-down lists your (and your teammates') models; a teammate's model shows the creator in parentheses.
When neither model nor size is selected, private curves are included in the search automatically; they are not included when catalog sizes are selected, only catalog models are selected, or an “Impeller Name” is entered (private curves have no impeller part number).
Results are placed in the “Private models (N)” group at the end, with a “Private” tag, and the price column shows “Private”.
Predicted speed and efficiency are calculated normally, and the efficiency and NPSHa criteria are evaluated.
See Data Search.
In Filter Search
They take part in searches and in calculations such as HR/ER and NPSHa together with catalog curves.
Step 5 shows “Private model parameters” and an “Edit” link.
If no construction data are entered, the note “No structural parameters entered: tip speed and casing pressure checks are N/A; pump-based HR/ER methods are unavailable.” is shown.
Private curves have no impeller, material, frame or expeller data, so the centrifugal seal, critical speed, bearing life and flange load do not apply.
See Filter Search 5: Configuration.
In Duty Simulation
Your own private curves can be simulated directly (Premium membership required); open the simulation from the “Duty Simulation” button in the list or from the search results. See Duty Simulation.
Features that do not apply
eQuote export needs catalog data such as impeller diameter, frame and suction size, so selections with private curves usually cannot be exported.
Bearing life, critical speed, flange load and centrifugal seal pressure checks do not apply.
Who can see private curves
Only you can see them; after you join a team, your teammates can also view and use them during the team's validity period and grace period. Other users cannot search for or view your private curves.
Range Chart
Plots the workspaces of your private models (including teammates' models when shared with a team) on one flow-head chart. It shows which duties the product range covers and where there are gaps; you can also enter a duty to see which models cover it. Available to Premium members. Click “Range Chart” in the private models list to open it, and “← My Private Models” to return.
How the workspace is defined
“Operating envelope”: uses each curve's own operating envelope (the envelope line on the curve page); curves without an envelope are drawn by speed range. Default.
“Speed range”: the part of the rated-speed curve between 70% and 120% of the flow at best efficiency, shifted to the minimum and maximum speeds by the affinity laws, enclosed as an area. Suited to pumps with variable-speed drives.
“Fixed speed”: the same part at rated speed, enclosed together with the matching part for an impeller trimmed by about 10% (flow ×0.9, head ×0.81). Suited to fixed-speed pumps with trimmed impellers.
Chart
Each curve is one semi-transparent area; the same model has the same colour. The best-efficiency point is marked with a small black dot and labelled with the size name (labels are omitted when there are more than 60 curves).
Hover over an area to show the model, size, best-efficiency flow / head / efficiency and rated speed; click an area to open that curve in a new window.
“Log scale”: ticked by default; flow and head both use logarithmic axes so that large and small sizes can be seen on one chart. Clear it to switch to linear axes.
“All installations”: limit the chart to horizontal, vertical or submersible curves.
“Mine / Whole team”: when you have joined a team, switch between your own curves and the whole team's.
“Export image”: saves the current chart as PNG.
Duty lookup
On the right, enter the flow (m³/h) and head (m). The duty is marked on the chart with a red diamond, and the model sizes whose workspace contains this point are listed below; click a name to open its curve. If no model covers the duty, “No model covers this duty” is shown.
Model legend
On the right, all models on the chart are listed (the heading shows the number of models and curves). Click a model to hide or show its areas; colours do not change when hidden. Curves with insufficient data (missing efficiency or too few points) cannot be drawn as workspaces; a note below reads “… more curves lack data and are not drawn”.
Series planning
Enterprise team members also have a “Series planning (Enterprise)” card below the range chart, for planning a product series:
1. Enter the target range: the lower and upper limits of flow Q (m³/h) and head H (m). If “Suggested speed” is 0, the rated speed of the nearest model is used; you can also enter the speed you plan to use.
2. Click “Analyse”. The platform divides the target range into a grid on logarithmic axes and counts how many of the team’s private models (using the current workspace definition and installation type) cover each cell.
3. On the chart, the target range is outlined with a red dashed frame. Light red cells are gaps (not covered by any model), light orange cells are overlaps (covered by 3 or more models), and red pins mark the positions of suggested new sizes, with their numbers.
4. The card shows the coverage rate, the overlap ratio and the number of models included. The table below lists suggested new sizes from the largest gap area to the smallest: suggested centre duty (flow, head), gap range, specific speed ns calculated at the suggested speed, suggested speed, nearest model and number of gap cells. Large gaps are split into several blocks, each with its own suggestion.
Click “Clear” to remove the planning marks from the chart. Specific speed ns = 3.65·n·√Q / H^0.75 (Q in m³/s); it helps choose the impeller type for a new size, and the size can then be designed at the centre duty in Hydraulic design.