Filter Search 4: Curve selection

This chapter covers step 4 of Filter Search, “Curve Selection”: search for usable pump performance curves based on the duty entered in the first three steps, compare and pick one curve in the results table, then go on to step 5, “Configuration”. A row of filter criteria, the number of curves and the “Search” button are at the top; the results table is below.

Workflow

1. Fill in the flow, head and slurry parameters in the first three steps (see Filter Search 1: Fluid details, Filter Search 2: Head details, Filter Search 3: More options).

2. Go to step 4, “Curve Selection”, and restrict the pump type, size and efficiency criteria as needed.

3. Click “Search”, then click a row in the results table to select a curve.

4. Click “Next” in the title bar to go to step 5, “Configuration”.

Tip: The “Select Assist” panel in the right column is visible in every step; watch for red crosses and warnings in it both before and after searching. See Select Assist (Engineering checks) for details.

Search criteria

Pump Type

Meaning: restricts the pump models (series) included in the search; multiple selection is allowed.

Range: the drop-down lists only models that match the “Pump Type” of step 1 (horizontal/vertical/submersible) and whose casing rated working pressure is not lower than the working pressure of this duty. The working pressure is estimated from the slurry specific gravity and the slurry head:

Working pressure (kPa) = Sm × 1000 × 9.81 × slurry head (m) / 1000

For example, with Sm = 1.4 and a slurry head of 40 m, the working pressure is about 549 kPa; models rated below this value do not appear in the list.

Default: none selected. Selecting no model is the same as searching all models in the list.

Options:

When there are only catalog models, the drop-down is a flat list.

When public manufacturer curves or your private models exist, the drop-down is grouped: “Catalog models”, “Public manufacturer curves · Slurry pumps” and so on (public curves are grouped by pump category), and “Private models”. Private models shared within a team show the owner in parentheses after the name. Private models appear only when you are signed in; see Private models for details.

Each time you enter this page, the model list is reloaded for the current duty; models that were selected but no longer meet the conditions are removed automatically.

Size

Meaning: restricts the pump sizes; multiple selection is allowed.

Range: lists only the sizes of the catalog models selected in “Pump Type”; if only private models or public curves are selected, the size list is empty.

Default: none selected, equivalent to all sizes of the selected models.

Related messages: after you change “Pump Type”, the selected sizes are cleared.

Select all / Clear all buttons

To the left of both the “Pump Type” and “Size” boxes there is a red double-arrow button (tooltip “Select all / Clear all”):

When not everything is selected, clicking it selects all items in the list (for “Pump Type”, select all includes catalog models, public manufacturer curves and private models);

When everything is already selected, clicking it clears all.

Efficiency at duty must satisfy

Meaning: when ticked, results are filtered by an efficiency condition; when not ticked, no efficiency filtering is done and the two radio buttons and input boxes below are grayed out.

Default: not ticked.

Options: when ticked, choose one of two.

Option · Input · Default · Pass condition

% Best Efficiency Flow · Two percentages joined by “to” · 70 to 100 · The duty flow as a percentage of the curve's best efficiency point (Best Efficiency Point, BEP) flow at the duty speed falls within the range (inclusive)

Min Efficiency · One percentage · 40 · The clear-water efficiency at the duty point is strictly greater than this value

%BEP flow = duty flow / BEP flow at duty speed × 100%

Worked example: a curve has a BEP flow of 60 L/s at the duty speed and the duty flow is 48 L/s, so %BEP = 80%, which is within the default range of 70–100: pass.

Effect on calculation: for single-stage pumps the check uses the clear-water head (slurry head ÷ HR), consistent with the point used for the predicted speed.

Related messages: curves that fail are hidden in the results; with “Show all curves” ticked they are shown in red, with “Failed BEP range criteria”, “Failed Min Eff criteria” or “Efficiency not predicted” in the comment column.

Filter using NPSHa

Meaning: when ticked, the net positive suction head available (Net Positive Suction Head available, NPSHa) is compared with the curve's net positive suction head required (NPSHr) at the duty point; curves with NPSHa − NPSHr ≤ 0 are judged as failing.

Default: not ticked.

Applies to: horizontal pumps only; ticking it has no effect for vertical and submersible pumps. If the curve cannot provide NPSHr, it is treated as passing.

Required input: NPSHa comes from the value calculated from the suction piping in step 2, or the value entered manually in “Override NPSHa”.

Note: If you tick this option without an NPSHa (suction piping not entered and not overridden), every curve that can provide NPSHr is judged as failing. Confirm NPSHa first in Filter Search 2: Head details.

Related messages: failing rows show “Failed NPSHa criteria” in the comment column.

Show all curves

Meaning: when ticked, the results also list curves that fail the efficiency/NPSHa conditions (red), superseded curves (gray), and unpurchased curves whose duty point is outside their operating range (red).

Default: not ticked; only curves that pass everything are listed.

How to choose: tick it when you want to find out “why a certain model does not appear”, and read the reason in the comment column.

Search button

Click “Search” to start searching; while searching, the results area shows “Data Searching”. When finished, “Curves: n” (n being the number of results) is shown below the button.

Before searching, the system performs two checks:

1. If the slurry head is in “Define” mode and the head is empty (or ≤ 0), the message “Please enter or calculate the slurry head first” appears and the search is not run.

2. If the nominal value of any of Flow (Q), Sm, Sw, Cw, Cv, Mass Flow Rate, Water (H), Slurry Head and Temperature in “Select Assist” has a red cross, a confirmation box appears.

Confirmation when inputs have errors

Title: Warning

Content: “There is at least one error in the inputed values (visible in the panel "Select Assist" in the dashboard). Do you want to execute the search ?”

Click “Yes”: ignore the errors and continue searching; the results may be empty or unreliable.

Click “No”: cancel the search and go back to the previous steps to correct the inputs.

Search rules

How candidate curves are chosen

The curve's flow range and head range must cover the duty point of each pump: single-stage pumps are compared using the clear-water head (slurry head ÷ HR); for multiple pumps in series, the head per pump = total head ÷ number of pumps.

The curve's alignment must match the “Pump Type” of step 1.

For a “Use Range” duty, the predicted speed, efficiency etc. in the results table are calculated at the maximum duty point.

The predicted speed is obtained after calculating the head ratio HR separately from the vane diameter of each row's impeller, so different impellers of the same model may have different predicted speeds.

When results are cleared automatically

When you return from the first three steps to step 4, “Curve Selection”, if the flow, head, pump type, pump system (single/multistage, number of pumps), duty mode, maximum flow/maximum head, slurry type or HR/ER calculation method differ from the last search, the results and the selected curve are cleared and you need to search again.

Tip: After you select a curve, if the HR/ER calculation method was “WB Slurry Based”, it is switched automatically to “WB Standard” (the same applies to private models with a vane diameter). This automatic switch does not count as a duty change: if you go back to a previous step and return to this page, the results and the selected curve are kept; they are cleared only if you change the HR/ER method yourself.

Results table

By default the results table is grouped by “Pump” (size), with group header rows in bold on a gray background. Public manufacturer curves are grouped by pump category (e.g. “Public manufacturer curves · Slurry pumps (5)”, light blue background), and private models form a separate group “Private models (n)” (light yellow background); these groups are always placed after the catalog curves. When there are more than 100 rows, a pagination bar appears below the table, with 100 rows per page.

Before a search, the table shows “Set criteria and click Search”; if a search returns no results, it shows “No matching results, please adjust criteria”.

Pump (column)

The pump size name. Clicking this column header sorts by the pump's discharge size rather than alphabetically by name.

Curve (column)

The curve name.

Pump Type (column)

The pump model (series) name.

Comment (column)

The conditions the curve failed, with multiple reasons separated by commas; “-” is shown if everything passes. For the meaning of each comment, see Comment meanings below.

Predicted speed (column)

Meaning: the pump speed interpolated from the curve family at the duty point (the clear-water head for single-stage pumps).

Unit: r/min.

“-” is shown when it cannot be predicted; unpurchased curves show a lock icon.

BEP (column)

Meaning: the efficiency at the curve's best efficiency point.

Unit: %, two decimal places.

Only values between 0 and 100 are shown; otherwise “-” is shown. Unpurchased curves show a lock icon.

Efficiency (column)

Meaning: the efficiency read from the clear-water efficiency surface at the flow per pump and the slurry head (not divided by HR), without ER or seal efficiency corrections. The “Min Efficiency” filter uses the clear-water head for single-stage pumps, so the two may differ slightly.

Unit: %, two decimal places; same rules as above.

Seal (column)

The seal type configured for the curve.

Liner Mtl (column)

The liner material configured for the curve.

Impeller Mtl (column)

The impeller material configured for the curve.

Type (column)

Alignment (horizontal/vertical/submersible).

Impeller (column)

Impeller part number; when a curve has several impellers, they are joined with commas.

Min Passage Size (column)

The maximum particle size the impeller can pass, in mm. “-” is shown when there is no data.

Vane σ (column)

Impeller vane diameter in mm; used in the pump-based HR/ER calculation. “-” is shown when there is no data.

Vane (column)

Vane information (number of vanes, type and other text).

Speed (column)

The rated maximum speed of the liner, in r/min. This column is hidden by default; you can show it via “Show” in the context menu.

Price (column)

Appears when curve payment is enabled; not included in the column settings:

Display · Meaning

Owned (with a check mark) · Purchased by you or your team; fully viewable

Private · Your own private curve; no purchase needed

Free · The curve is free

n coins · The price to buy the curve; see Curve purchases

After you buy a curve in the curve pop-up, the price column refreshes automatically when you return to this page (the window regains focus).

Row colors

Color · Meaning

Blue text · All conditions passed

Red text · At least one condition not met (only when “Show all curves” is ticked)

Gray text · Curve superseded (only when “Show all curves” is ticked)

Light blue background · The currently selected curve

Comment meanings

Comment · Meaning · What to do

Failed NPSHa criteria · “Filter using NPSHa” is ticked and NPSHa is not greater than the curve's NPSHr · Raise the suction level, enlarge the suction pipe diameter or choose a pump with a lower NPSHr

Failed BEP range criteria · The %BEP of the duty flow is not within the set range · Widen the range, or choose a better-sized pump

Failed Min Eff criteria · The efficiency at the duty point is not higher than the set minimum efficiency · Lower the threshold or choose another pump

Efficiency not predicted · The duty point lies outside the efficiency surface, so no efficiency can be obtained; treated as failing · Usually means the duty is outside the usable region of this curve

Curve Superseded · The curve status is superseded; it has been replaced by a newer version · Prefer valid curves

Within duty range · buy to see speed/efficiency · Unpurchased curve: the duty point is within its operating range, but readings such as speed and efficiency are shown only after purchase · Purchase, then search again

Duty point outside this curve's range · Unpurchased curve: the duty point is outside its operating range (red, only with “Show all curves”) · This curve can generally be ignored

Private, public and locked curves

Private curves: the first column has a “Private” tag; curves shared within a team show “Private · owner”. Private curves have no impeller, material, frame or other configuration data, so step 5 shows their structural parameters instead; see Filter Search 5: Configuration for details.

Public manufacturer curves: the first column has a “Public” tag; they come from manufacturers' published data and are for reference only; see Curve purchases for details.

Locked curves: unpurchased curves have a lock icon in the first column (tooltip “Not purchased: buy to view the curve, predicted speed and efficiency”), and the predicted speed, BEP and efficiency columns show lock icons. Unpurchased curves are not subject to the NPSHa, BEP range and minimum efficiency filters; only whether the duty point is within their operating range is checked.

Note: An unpurchased curve can be selected and taken to step 5, but it has no predicted speed or efficiency, so you cannot proceed to step 6; “Select Assist” shows “Curve not purchased: checks and bearing / critical speed calculations require buying this curve”. After purchasing, search again.

Table actions

Click to select

Click a row to select that curve (light blue background); “Select Assist” refreshes immediately and the “CurveVersion” item changes to passed. Group header rows cannot be selected.

Double-click to view

Double-click a row to open the curve in a new window, with the duty point marked automatically for the current duty. For how to use the curve window, see Curve Viewer.

Sorting by column header

Click a column header to sort ascending by that column; click again to sort descending. An up/down triangle is shown after the column name. Until you click a column header, the system default order is kept. The sort order is saved in the current browser.

Context menu

Right-clicking a result row first selects the row and then opens the menu; you can also right-click the table header to open the menu (in that case “View” and “Duty Simulation” are unavailable).

Show

The submenu lists all columns; checked columns are currently shown. Click to toggle show/hide. At least one column must remain. Column settings are saved in the current browser.

Group By

The first submenu item is “No Grouping”, followed by the currently shown columns; click one to group by that column's values. Grouping is by “Pump” by default. If you hide the column used for grouping, grouping is switched off automatically.

View

Same as double-clicking: opens the curve in a new window with the duty point marked.

Duty Simulation

Opens Duty Simulation in a new tab, carrying over all current duty, slurry and piping parameters; see Duty Simulation for details.

Going to the next step

The “Next” button and step 5, “Configuration”, in the left column become available only after you select a curve. When you click, the page shows a “Calculating configuration” overlay while the system calculates the impeller, frame, bearing assembly, materials, checks, bearing life and so on in one go; when done, it switches to step 5 automatically. If the same curve has already been calculated, you go straight in without recalculating.

FAQ

No search results

Check whether flow and head have red crosses in “Select Assist”.

If the “Pump Type” list is empty or very short, the slurry head may be too high and exceed the casing's rated pressure.

Tick “Show all curves” to see the filtered-out curves and the reasons.

If the “CurveVersion” item shows “No curves available for your flow system head. Check your flow and system head”, no curve covers the duty point at all.

Step 6 is greyed out

The selected curve has no predicted speed or efficiency (for example, it is unpurchased or the duty point lies outside the efficiency surface). Choose another curve, or purchase it and search again.