Glossary
This chapter explains, by topic, the pump, slurry, piping, engineering check, bearing, duty simulation and platform terms and symbols used in PUMPVIZ. Each term is given with its English name or symbol and a brief explanation; for detailed calculation methods, see the linked chapters.
Pump performance
Flow rate (Q)
The volume of liquid or slurry delivered by the pump per unit time. Available units: L/s, m³/h, m³/min, USGPM.
Head (H)
The energy imparted by the pump to a unit weight of liquid, expressed as the height of a liquid column, in m or ft.
Water head (Hw)
The head of the pump when pumping clear water. Manufacturers' performance curves are all clear-water curves.
Slurry head (Hm)
The actual head of the pump when pumping slurry, expressed as a column of slurry: slurry head = water head × HR.
Shut-off head
The pump head at zero flow. If the pump's shut-off head is lower than the system static head, the pump cannot deliver any flow.
Speed (n)
Revolutions of the pump shaft per minute, in r/min (rpm).
Rated speed
The reference speed of the performance table or curve. All speed lines on the curve page have the same line width; the rated speed is shown in the “Rated speed n r/min” label at the top of the regular curve page. %BEP is also based on the best efficiency point at the rated speed.
Predicted speed
The speed the pump needs to operate at a given flow and head, interpolated from the curve's speed surface. See Data Search.
Efficiency (η)
The ratio of the hydraulic power delivered by the pump to the input shaft power, in %.
Best Efficiency Point (BEP)
The duty point with the highest efficiency at the rated speed. The farther from the BEP, the lower the efficiency and the greater the vibration and wear.
%BEP (percent of BEP flow)
The duty flow as a percentage of the BEP flow at the equivalent head: %BEP = Q ÷ (Q_BEP × √(H ÷ H_BEP)) × 100. See Duty Simulation.
Preferred Operating Region (POR)
The flow range of roughly 70%–120% of BEP; within it the pump runs with high efficiency, low vibration and long life.
Shaft power / absorbed power (P)
The input power required at the pump shaft, in kW. For slurry it is corrected for the slurry specific gravity and ER: P ≈ 9.81 × Q (L/s) × H (m) × Sm ÷ (1000 × η × ER), where H is the slurry head and η is a decimal (e.g. 0.70).
Net Positive Suction Head required (NPSHr)
The minimum suction energy the pump needs at a given duty to avoid cavitation; it is determined by the pump itself and increases with flow.
Net Positive Suction Head available (NPSHa)
The suction energy the suction system can actually provide, determined by the suction level, atmospheric pressure, vapor pressure and suction pipe losses. See Filter Search 2: Head details.
NPSH margin
NPSHa − NPSHr. Cavitation is likely when the margin is too small (less than 10% of NPSHr or 0.6 m).
Cavitation
The phenomenon in which bubbles form when the pump inlet pressure drops below the liquid's vapor pressure and then collapse in the high-pressure region, causing head loss, noise and impeller damage.
Affinity laws
The relationships for converting performance when the speed or impeller diameter of the same pump changes: flow is proportional to speed, head to the square of speed, and power to the cube of speed.
Impeller trimming
Machining down the impeller outside diameter to reduce head and flow; performance changes according to the similarity relationships. See Duty Simulation.
Specific speed (nq)
A parameter characterizing the hydraulic type of an impeller: nq = n × √Q_BEP ÷ H_BEP^0.75 (r/min, m³/s, m). Typically 10–120 for centrifugal pumps.
Suction specific speed (nss)
A parameter characterizing suction performance: nss = n × √Q_BEP ÷ NPSHr_BEP^0.75.
Tip speed
The peripheral velocity at the impeller outer edge: π × impeller outside diameter × speed ÷ 60, in m/s. Excessive tip speed accelerates wear; the check compares it with the allowable value for the impeller material.
Performance curve
A chart showing the relationship between pump flow and head, efficiency, power and NPSHr. See Curve Viewer.
Speed curves
Flow–head curves at different speeds on the same curve chart, each labeled with its speed.
Diameter curves
Some curves are organized by impeller diameter: flow–head curves for different trimmed diameters at the same speed, each labeled with its diameter (mm). For these curves, readings and simulations use “Impeller Diameter” instead of “Speed”. See Curve Viewer.
Slip factor (σ)
A correction factor for the deviation of the flow leaving the impeller from the vane direction with a finite number of vanes; the closer to 1, the smaller the loss of theoretical head. See Impeller quick estimate.
Iso-efficiency curves
Lines on the curve chart connecting points of equal efficiency, usually U-shaped, with the highest efficiency on the innermost line.
Iso-NPSHr curves
Lines on the curve chart connecting points of equal NPSHr, shown as vertical dashed lines.
Rising / drooping head curve
A curve whose head first rises and then falls as flow increases. Operation to the left of the hump, or in parallel, may be unstable.
System and piping
System curve
The curve of the head required by the piping system as a function of flow; it starts at the static head (including terminal pressure) and rises with the square of the flow.
Operating point
The intersection of the pump curve and the system curve, i.e. the flow and head at which the pump actually operates.
Duty point
The flow and head required by the design; also the point marked on the curve chart.
Static head
The height difference between the discharge liquid level and the suction liquid level; it does not change with flow.
Terminal pressure
The gauge pressure that must be maintained at the end of the discharge pipe (e.g. cyclone inlet pressure), in kPa; it is converted by P ÷ (9.81 × Sm) and added to the system head. See Filter Search 2: Head details.
Total Equivalent Length (TEL)
The straight pipe length of the piping plus the equivalent length of the fittings, used to calculate friction losses.
Fitting resistance coefficient (K factor)
The local resistance coefficient of fittings such as bends, tees and valves; local loss = K × v² ÷ 2g. Note: in the Filter Search piping input, the “K Factor” of a pipe section under the Darcy model is the absolute pipe wall roughness (mm), not a fitting resistance coefficient; the fitting resistance coefficient is entered in the “Factor” of the “Fittings” row. See Filter Search 2: Head details.
Darcy–Weisbach equation
The general formula for calculating pipe friction losses from a friction factor; the default friction model in Filter Search.
Hazen-Williams equation (C factor)
An empirical friction loss formula for clear-water piping; the C factor indicates the smoothness of the pipe wall — the larger the value, the lower the resistance.
Pipe velocity
The average velocity of the slurry in the pipe, in m/s. Too low a velocity causes deposition; too high a velocity accelerates wear.
Wave speed (a)
The propagation speed of the pressure wave in the pipe during pump-trip water hammer; it depends on the pipe material, wall thickness and fluid.
Pipe period (2L/a)
The time for a pressure wave to travel to the end of the pipe and back. Water hammer is most severe when the valve closing time is shorter than the pipe period.
Water hammer
Pressure surges caused by a sudden change in pipe velocity when a pump trips or a valve closes suddenly; they can cause overpressure or column separation. See Duty Simulation.
Slurry properties
Solids specific gravity (S)
The ratio of the density of the solid particles to the density of water.
Liquid specific gravity (Sw)
The specific gravity of the liquid in the slurry; 1 for clear water.
Slurry specific gravity (Sm)
The specific gravity of the slurry as a whole, determined by S, Sw and the concentration.
Concentration by volume (Cv)
Solids volume as a percentage of the total slurry volume.
Concentration by weight (Cw)
Solids mass as a percentage of the total slurry mass. See Filter Search 1: Fluid details.
Median particle size (d50)
50% of the particles by mass are smaller than this size, in µm.
Fines content (Cwfp)
The weight percentage of fine particles smaller than 75 µm in the total solids; it affects derating and settling velocity.
Head Ratio / Efficiency Ratio (HR / ER)
The reduction factors for head and efficiency relative to clear water when pumping slurry: HR = slurry head ÷ water head, ER = slurry efficiency ÷ water efficiency; both are not greater than 1. See Filter Search 3: More options.
Settling velocity (V_L)
The critical pipe velocity at which solid particles begin to deposit at the bottom of a horizontal pipe; below it there is a risk of deposition and pipe blockage.
Critical velocity
The pipe velocity at which a non-Newtonian slurry changes from laminar to turbulent flow; used to determine the recommended pipe inside diameter.
Non-Newtonian fluid
A slurry whose viscosity varies with shear rate, such as a high-concentration fine-particle slurry; commonly described by the Bingham plastic model.
Yield stress (τ₀)
The minimum shear stress needed for a Bingham plastic slurry to start flowing, in Pa.
Froth Volume Factor (FVF)
The ratio of the froth slurry volume to the volume of liquid and solids in it; used to calculate the aerated flow (Qf = Q × FVF) and froth derating. The maximum value in Filter Search is 1.75. See Filter Search 1: Fluid details.
Solids mass flow rate
The mass of solids delivered per unit time, in t/h.
Engineering checks and components
Select Assist (selection assistant)
The panel of 15 engineering checks shown in real time at the bottom of Filter Search. See Select Assist (Engineering checks).
Casing pressure
The maximum pressure the pump casing is subjected to, compared with the casing's rated working pressure.
Gland seal
A seal in which packing is compressed around the shaft; usually requires gland water.
Centrifugal seal / expeller
A dynamic seal that uses the centrifugal force generated by an expeller to prevent slurry from leaking out. It leaks when the inlet pressure is too high, so the seal pressure must be checked.
Mechanical seal
A seal in which the faces of a rotating ring and a stationary ring are pressed together; low leakage.
Liner
The wear-resistant layer inside the pump casing, in materials such as metal and rubber; each liner has a rated maximum speed.
Frame
The component that supports the shaft and bearings; it determines the power that can be transmitted.
Bearings and rotor
Bearing L10 life
The number of operating hours that 90% of a batch of identical bearings will reach. In Filter Search, values below 5000 h are marked red. See Bearing Life, Critical Speed and Flange Load.
Drive End / Wet End (DE / WE)
The drive end is the bearing on the motor side; the wet end is the bearing on the impeller side.
Shaft stress
The calculated shaft stress at the drive end, wet end and thread, expressed as a percentage of the allowable value; 100% means the limit is exceeded.
Critical speed (NCr1)
The speed at which the rotor resonates. The safe zone is an operating speed below 0.8 × NCr1, or between 1.2 and 1.6 × NCr1.
Nozzle loads
The pipe forces and moments the pump suction and discharge flanges are allowed to carry.
Duty Simulation
Design point
The design flow and slurry head given by the duty in the simulation, shown on the chart as a gray hollow circle; when no duty or piping is given, the BEP at the curve's rated speed is used as the design point. See Duty Simulation.
Throttling
Closing the discharge valve partially to increase system resistance, moving the operating point toward lower flow.
Variable Frequency Drive (VFD)
Regulating the flow by changing the motor speed; usually more energy-efficient than valve throttling.
Series / Parallel
Series: several pumps connected end to end, with their heads added; parallel: several pumps feeding the same pipeline simultaneously, with their flows added.
Level variation
Changes in the suction or discharge liquid level change the static head, and the operating point moves accordingly.
Platform features
Catalog curve
A pump curve from the platform's curve library; some must be purchased before they can be viewed.
Public manufacturer curve
A curve generated from the performance data tables published on a manufacturer's website; for reference only, and tagged “Public”.
Partly estimated
A curve in which one section is not original data but has been filled in by estimation based on the general characteristics of centrifugal pumps (e.g. the shut-off point and high-flow end of public manufacturer curves, or curves saved from the impeller quick estimate); allow a margin when reading values in these sections. See Curve Viewer.
Private model
A pump curve you entered yourself, visible only to you and your teammates. See Private models.
Saved selection
A single selection saved in Filter Search. See Saved Selections.
Project / Duty / Selection
A project contains multiple duties (equipment items); each duty has one primary selection and any number of alternative selections. See Projects.
Primary / Alternative
Each duty has exactly one primary selection; the others are alternatives.
Tag number
The number identifying the equipment in the process flow.
Needs recalculation
A selection imported from a file or added from Data Search that does not yet have complete calculation results. See Projects.
eQuote
The project data file format used by the quotation system; projects can be exported as eQuote XML.
Coin
The platform's unit of settlement, used to purchase curves and to subscribe to membership and teams. See Top-up and account.
Premium membership
The membership status that unlocks duty simulation, private model entry, impeller quick estimate and custom watermarks. See Membership and curve watermarks.
Team
The team edition in which several people share projects, saved selections, private models and purchased curves. See Team Edition.
Team owner
The person who set up the team; has all permissions, and the team balance is their account balance.
Team balance
The team owner's account balance, which authorized members can use to purchase curves for the team.
Grace period
The read-only period after a team expires; members can still view shared data but cannot modify it.
Two-step verification (2FA)
When signing in, in addition to the password, a time-based code generated by an Authenticator app on your phone is verified. See Account and security.
Recovery code
8 one-time codes generated when two-step verification is turned on; use them instead of a verification code to sign in if you lose your phone.
Watermark
Text or an image tiled diagonally across the curve chart to identify its source. See Membership and curve watermarks.