Filter Search 3: More options
This chapter describes step 3 of Filter Search, “Preferences”: setting the pump system (single stage or multi-stage in series) and the number of pumps, recording the pump application, and choosing the calculation method for the head ratio / efficiency ratio (HR/ER). HR/ER determines the conversion between slurry head and water head and between slurry efficiency and water efficiency, and directly affects the curve search, speed prediction and power calculation.
Page overview
Area · Content
Pump System · Single Stage / Multi Stage (toggle buttons); after choosing Multi Stage, Series / Parallel and No. of Pumps appear on the same row
Pump Application · Drop-down list; the options change with the pump type and slurry type
HR/ER Method · HR/ER method drop-down, with “HR: value ER: value” shown live on the right; when the method is “User Defined...”, “Edit custom HR/ER...” appears
Changes on this page immediately recalculate HR/ER and refresh the right-hand “Select Assist” panel.
If you change the pump system, the number of pumps or the HR/ER method and then go to the “4 Curve Selection” page, the previous search results are cleared and you need to search again. The automatic switch of the HR/ER method from “WB Slurry Based” to “WB Standard” when a curve is selected does not count as a change and does not clear the results.
The “5 Configuration” page has the same HR/ER method drop-down (titled “HR/ER Method”); both are the same setting; see Filter Search 5: Configuration.
Pump System
Single Stage
Meaning: one pump handles the whole flow and head of the system.
Default: selected.
Effect on calculation: the duty of the pump is the system flow Q and the system head; the curve search and speed prediction use water head = slurry head ÷ HR.
Multi Stage
Meaning: the system is handled by several pumps in combination; when selected, “Series”, “Parallel” and “No. of Pumps” appear.
Availability: only horizontal pumps can be multi-stage. If you change the pump type to Vertical or Submersible on the “1 Flow Details” page, the pump system automatically returns to single stage and the number to 1; even if you choose “Multi Stage” again afterwards, the calculation is still done as single stage.
Linked behavior:
With Multi Stage selected, the “Zl (Dredging)” input on the “2 Head Details” page is hidden (dredging supports only horizontal single stage).
With Multi Stage and more than 1 pump, the seal type on the “5 Configuration” page does not offer the centrifugal seal; a previously selected centrifugal seal changes to a gland seal automatically.
With more than 1 pump, the view mode of the curve toolbar on the “5 Configuration” page offers both “Single Stage Curve” and “Multi Stage Curve”.
Series
Meaning: several pumps connected end to end, with the same flow and added heads; used for long-distance or high-head transport where one pump does not give enough head.
Default: selected by default after choosing “Multi Stage”.
Duty of each pump:
Flow per pump = Q
Water head per pump = slurry head ÷ HR ÷ n
n is the number of pumps.
Example (hypothetical data): slurry head 90 m, HR = 0.90, 3 pumps in series; each pump's curves are searched with a water head of 90 ÷ 0.90 ÷ 3 ≈ 33.3 m and flow Q.
Parallel
Meaning: several pumps running side by side, with the same head and added flows.
Availability: in the current version this option is grayed out and cannot be selected. If you need a parallel arrangement, select each pump separately with “Single Stage” using the flow per pump (Q ÷ number of pumps).
No. of Pumps
UI text: “No. of Pumps”, a number box with increase/decrease buttons.
Shown when: “Multi Stage” is selected.
Range: 1–20, default 1.
Effect on results: in series, each pump takes 1/n of the total head; the number is also shown in “No of Pumps:” of the selection summary on the “6 Project Options” page and is saved with the selection report.
Common mistake: choosing “Multi Stage” but leaving the number at 1, so each pump still carries the whole head.
Pump Application
UI text: the “Pump Application” drop-down.
Purpose: records the category of service the pump is used for, saved with the selection as part of the duty information. In the current version it is not used for curve filtering or any calculation: choosing “All” does not miss any curves, and choosing another option does not reduce the search results.
Available options and automatic selection
Options depend on conditions:
Condition · Options
Slurry type is Froth · All, Froth
Pump type is Vertical or Submersible (not froth slurry) · All, Chemical
Other (horizontal pumps) · All, Severe Duty (Class 4), Heavy Duty (Class 3), Medium Duty (Class 2), Light Duty (Class 1), Froth, Milling, Dredging
Default: All.
Automatic selection rules (applied when you change the slurry type, pump type, Zl or pump system):
1. When the slurry type is Froth or Non-Newtonian, it is set to “Froth” automatically (if that option is in the current list).
2. Otherwise, if Zl is entered on the “2 Head Details” page, it is set to “Dredging” automatically.
3. If the current option is not in the new list, or “Froth” is selected but the slurry type is no longer froth/non-Newtonian, it returns to “All”.
Tip: A manually chosen application may be overwritten automatically when the conditions above change; check it once more before you finally save the selection.
All
No application specified.
Severe Duty (Class 4)
Coarse particles, high concentration, highly abrasive duties, e.g. mill discharge and coarse tailings transport.
Heavy Duty (Class 3)
General slurry transport with fairly strong abrasion, with less wear than severe duty.
Medium Duty (Class 2)
Duties with medium particle size and concentration and moderate abrasion.
Light Duty (Class 1)
Fine particles, low concentration, mildly abrasive duties, e.g. fine tailings and thickener overflow.
Froth (application)
Transport of aerated slurries such as flotation froth. Selected automatically when the slurry type is Froth or Non-Newtonian.
Milling
Pumps in grinding and classification circuits, e.g. cyclone feed pumps.
Dredging
Duties drawing sediment from under water, such as dredging and sand mining. Selected automatically when Zl is entered.
Chemical
Transport of chemical media where corrosion is the main concern. Appears only for Vertical and Submersible pumps.
Head ratio / efficiency ratio (HR/ER)
What HR and ER mean
When pumping a slurry containing solids, both the head and the efficiency of the pump are lower than with water. This derating is described by two ratios:
HR = slurry head ÷ water head ER = slurry efficiency ÷ water efficiency
Water head = slurry head ÷ HR Slurry efficiency = water efficiency × ER
Slurry shaft power P (kW) ≈ 9.81 × Q (L/s) × H (m) × Sm ÷ (1000 × η_water × ER)
Pump manufacturers' performance curves are water curves, so the program first converts the slurry head into water head with HR, then searches and predicts the speed on the water curves; for power and the motor check, the efficiency is then corrected with ER.
HR and ER are generally not greater than 1 (except user-defined values); the smaller the value, the greater the derating. When the slurry type is “Water”, HR = ER = 1 and the selected method does not affect the result.
Example (hypothetical data): slurry head 28.1 m, HR = 0.90, so the pump is selected on the water curve at 28.1 ÷ 0.90 ≈ 31.2 m; with Q = 50 L/s, Sm = 1.23, water efficiency 70% and ER = 0.90, the slurry shaft power ≈ 9.81 × 50 × 28.1 × 1.23 ÷ (1000 × 0.70 × 0.90) ≈ 26.9 kW.
Available methods
The content of the “HR/ER Method” drop-down depends on the slurry type and on whether a curve has been selected on the “4 Curve Selection” page:
Slurry type · No curve selected · After selecting a curve
Single Solid, Two Solid Mix, Coal Mixture · WB Slurry Based, Coal Industry, User Defined... · WB Standard, WB Pump Based, WB Slurry Based, Coal Industry, User Defined..., ANSI / HI 12.1 - 12.6
Water · WB Slurry Based, User Defined... · WB Standard, WB Pump Based, WB Slurry Based, User Defined..., ANSI / HI 12.1 - 12.6
Froth · Froth, User Defined... · Froth, User Defined...
Non-Newtonian · Non-Newtonian, User Defined... · Non-Newtonian, User Defined...
Default method: WB Slurry Based; switching to Froth changes it to “Froth” automatically, switching to Non-Newtonian changes it to “Non-Newtonian”, and switching to Water changes it to “WB Slurry Based”.
After selecting a curve: if the current method is WB Slurry Based, it changes to “WB Standard” automatically (it stays WB Slurry Based for private models without a vane diameter; see Private models).
If the current method is not in the new list, it changes to the first item of the list automatically.
Special types: when the slurry type is “Coal Mixture”, HR/ER always comes from the HR and ER in the Coal Mixture block on the “1 Flow Details” page, and the method chosen here has no effect; for “Two Solid Mix” the preset values of the mixture type are used, and only with “User Defined...” or “Coal Industry” do the values in the dialog apply.
HR/ER displayed values
Location: to the right of the method drop-down, “HR: value ER: value”, with 2 decimal places; “-” when it cannot be calculated.
They are the same results as Hr and Er at the bottom of the “1 Flow Details” page.
Methods compared
Method · Main inputs · Vane diameter needed? · How ER is obtained
WB Slurry Based · d50, S, Cw · No · Same as HR
WB Pump Based · Vane diameter, d50, S, Cv · Yes · Same model; additional reduction when Cv exceeds 20%
WB Standard · Vane diameter, d50, S, Cv, Cwfp · Yes · Derived from HR and Cv
ANSI / HI 12.1 - 12.6 · Vane diameter, d50, S, Cv, Cwfp · Yes · Estimated (derived from HR and Cv)
Froth · Froth volume factor FVF · No · Calculated from FVF
Non-Newtonian · Slump plate reading · No · Value taken by reading band
Coal Industry · Pump function preset · No · Preset value
User Defined... · Manual entry · No · Manual entry
The vane diameter comes from the impeller of the selected curve and is used once the impeller is determined on the “5 Configuration” page.
WB Slurry Based
Meaning: an empirical method that estimates the derating from the slurry properties, without needing to know the size of a specific pump.
When to use: the preliminary stage before a pump has been chosen; all kinds of ordinary single-solid slurries.
Inputs needed: particle size d50, solids SG S, concentration by weight Cw.
Characteristics: ER takes the same value as HR. The larger d50 and S and the higher Cw, the greater the derating; for very fine particles HR = ER = 1.
WB Pump Based
Meaning: an empirical method that adds the impeller size to WB Slurry Based. For the same slurry, a large impeller is derated less than a small one.
When to use: when a curve has been chosen and the derating needs to be assessed for the specific pump.
Inputs needed: vane diameter, d50, S, concentration by volume Cv.
ER: uses the same model as HR; equal to HR when Cv does not exceed 20%, reduced further above 20%.
Availability: appears only after a curve is selected on the “4 Curve Selection” page. Until the vane diameter is determined (before the impeller is determined on the “5 Configuration” page), the HR/ER shown on this page falls back to the WB Slurry Based method.
WB Standard
Meaning: the standard derating method taking into account impeller diameter, particle size, solids SG, concentration by volume and fines content; it is the default method after a curve is selected.
When to use: ordinary slurry selection once a curve has been chosen; recommended as the first choice.
Inputs needed: vane diameter, d50, S, Cv, fines content Cwfp (“Fines (-75µm) wt% of total solids” on the “1 Flow Details” page).
ER: derived from HR and Cv: when Cv does not exceed 20%, ER equals HR; above 20%, it is reduced further as Cv increases.
Availability: appears after a curve is selected. Until the vane diameter is determined, HR falls back to the WB Slurry Based method.
ANSI / HI 12.1 - 12.6
Meaning: calculates HR by the method of the American National Standard / Hydraulic Institute ANSI/HI 12.1–12.6 (rotodynamic centrifugal slurry pumps).
When to use: when the project specification requires slurry derating to be assessed to the ANSI/HI standard.
Inputs needed: vane diameter, d50, S, Cv, fines content Cwfp.
ER: an estimate, derived from HR and Cv by the same rule as WB Standard; in the “User Defined HR / ER” dialog this row is labeled “ANSI/HI (ESTIMATED ER)”.
Availability: appears after a curve is selected. Until the vane diameter is determined (before the impeller is determined on the “5 Configuration” page), HR is estimated by the WB Slurry Based method and ER is then derived from that HR by the rule above; during the search, each curve is calculated with the vane diameter of its own impeller.
Froth (HR/ER method)
Meaning: estimates the derating of aerated slurries from the froth volume factor FVF.
When to use: when the slurry type is Froth, it is the only calculation method (User Defined is also available).
Inputs needed: the froth volume factor FVF on the “1 Flow Details” page.
Characteristics: when FVF does not exceed 1.4, a fixed small derating is applied; above 1.4, HR and ER drop markedly as FVF increases, with FVF capped at 1.75 in the calculation. If FVF is empty, the WB Slurry Based method is used.
Non-Newtonian (HR/ER method)
Meaning: takes the derating for Bingham plastic slurries from the slump plate reading.
When to use: when the slurry type is Non-Newtonian, it is the only calculation method (User Defined is also available).
Inputs needed: the Slump Plate Reading on the “1 Flow Details” page.
Characteristics: HR and ER take fixed values by reading band; the 5-7 band is derated less than the 3-5 band; ER is derated more than HR.
Coal Industry
Meaning: typical empirical HR/ER values for the various pumps of a coal preparation plant.
When to use: cyclone feed, flotation feed, dense medium, thickener underflow, tailings and other pumps in a coal preparation plant.
Inputs needed: choose the pump function in the “Coal Industry HR / ER” dialog that opens.
Availability: not shown when the slurry type is “Water”. When the slurry type is “Coal Mixture”, choosing this item does not open the dialog; HR/ER is taken directly from the Coal Mixture block.
Note: the HR and ER written by the dialog are the same values as the HR and ER in the Coal Mixture block on the “1 Flow Details” page. To change the pump function, first switch to another method, then choose “Coal Industry” again.
User Defined...
Meaning: specify HR and ER directly.
When to use: when you have manufacturer test data or field measurements, or the owner has specified derating factors.
Inputs needed: fill in the “User Defined HR / ER” dialog that opens.
Note: when the slurry type is “Water” or “Coal Mixture”, custom values have no effect (the values are 1 and the Coal Mixture block values, respectively).
Edit custom HR/ER...
Shown when: the method is “User Defined...”; this link button appears below the drop-down.
Purpose: reopens the “User Defined HR / ER” dialog, pre-filled with the current custom HR and ER, which you can change and confirm.
User Defined HR / ER dialog
Opens when you choose “User Defined...” in the method drop-down or click “Edit custom HR/ER...”. The left column of the dialog shows the values calculated by each method (read-only reference), and the right column is for custom input.
CALCULATED (left column)
Lists the HR and ER calculated by each method for the current duty, with 2 decimal places; “-” where they cannot be calculated:
Row · When it has a value
WB Slurry Based · Always calculated
WB Pump Based · When the vane diameter is determined
ANSI/HI (ESTIMATED ER) · When the vane diameter is determined
WB Standard · When the vane diameter is determined
Froth · When the slurry type is Froth
Non Newtonian · When the slurry type is Non-Newtonian
You can compare these values before deciding on your custom values.
Custom HR and ER (right column)
HR, ER: number boxes with increase/decrease buttons, minimum 0.01, step 0.01, 2 decimal places.
Pre-filled values: when you first choose “User Defined...” from the method drop-down, the WB Pump Based values are pre-filled if you are on the “5 Configuration” page; otherwise the current HR and ER are pre-filled; if neither exists, 1 is pre-filled. When opened through “Edit custom HR/ER...”, the custom values last confirmed are pre-filled.
Common mistake: entering HR and ER as percentages (e.g. 90); enter 0.90 instead.
OK and Cancel (custom HR/ER)
OK: saves the custom values and recalculates immediately; an empty input is treated as 1.
Cancel (or closing the dialog): does not save the changes. If custom values have never been confirmed before, the method reverts to the one in use before you chose “User Defined...”.
Coal Industry HR / ER dialog
Opens when you choose “Coal Industry” in the method drop-down (not when the slurry type is Coal Mixture).
Pump Function preset table
Columns: selection marker (▶), Pump Function, HR, ER.
Preset rows: Cyclone Feed(40mm coal size), Cyclone Feed(8mm coal size), Flotation Feed, Filtrate, Correct Density Medium, Over Dense Medium, Dilute Medium, Thickener Underflow, Tailings Disposal (Fine Coal Only). The HR and ER of each row are shown directly in the table.
Selected by default: the row whose values equal the current HR and ER (usually the first row when opened for the first time).
Operation: click a row to select it; double-clicking a row is the same as selecting it and clicking OK.
OK and Cancel (Coal Industry)
OK: writes the HR and ER of the selected row into the duty and recalculates immediately. The button is grayed out when no row is selected.
Cancel (or closing the dialog): HR and ER are not changed. If no row is selected in the table, the method reverts to the one in use before you chose “Coal Industry”; if a row is already selected, “Coal Industry” stays and the current values are kept.
Common mistakes
You want several pumps in series but only chose “Multi Stage” without changing the number of pumps, so each pump is still searched with the whole head.
You choose “Multi Stage” for a vertical or submersible pump; the calculation is still done as single stage.
You assume that “Pump Application” filters curves; it is only saved with the selection as a record.
You want to use WB Standard, WB Pump Based or ANSI/HI before selecting a curve; these three methods appear only after a curve is selected on the “4 Curve Selection” page.
After choosing ANSI / HI 12.1 - 12.6, HR is first estimated by the WB Slurry Based method until the impeller is determined, and during the search each curve is calculated with the vane diameter of its own impeller; once the impeller is determined on the “5 Configuration” page, the ANSI/HI values of that impeller are shown.
You look at the old search results right after changing the HR/ER method; when you return to the “4 Curve Selection” page you need to search again.