Duty Simulation
Duty Simulation uses the selected pump curve and your piping system to find the pump's actual operating point, and lets you drag parameters such as speed, valve, impeller trim, wear, slurry and piping to watch in real time how the operating point changes. This chapter covers how to open the simulation page, each operating parameter, each reading and how it is calculated, the chart and the analysis tabs, the warnings, and export and printing. The simulation page is under “Duty Simulation” in the left Workspace.
Requirements
Sign-in and Premium
Duty Simulation requires signing in and is a Premium feature. When a regular user opens it, the message ““Duty Simulation” is a Premium feature” and a “Get Premium” button are shown. For how to subscribe, see Membership and curve watermarks.
Curve purchase
If the curve used for the simulation must be purchased and has not been, the same purchase panel as on the curve page is shown; the page refreshes automatically after purchase. See Curve purchases.
Private curves
Your own Private models, private models shared by teammates after you join an enterprise team, and public manufacturer curves can all be simulated; private curves that do not belong to you and are not shared within your team cannot be simulated (the message “This curve has no usable speed curve set” appears).
Opening a simulation
The simulation page does not select curves itself; it must be opened from one of the entry points below, carrying a curve and a duty. The opened simulation is remembered, so next time you can open it directly from the Workspace.
Opening from Data Search
In the Data Search results, right-click a curve and choose “Simulate”, or select a row and click the “Simulate” button in the results bar. The simulation uses the search duty (clear water) and the units of the last search; no piping is entered, and the system curve is estimated from the design point. If no duty was entered in the search, the BEP at the curve's rated speed is used as the design point. NPSHa entered in Data Search is not carried into the simulation; NPSHa and NPSH margin show “-”. The tab row shows “From Data Search (water duty, no piping)”.
Opening from Filter Search
In Filter Search, right-click a curve in step 4 and choose “Simulate”, or click the “Simulate” button in step 5 or step 6. The simulation carries the complete Filter Search duty: slurry parameters, Hr/Er, seal, number of pumps and arrangement, piping, NPSHa and so on. This is the most complete way to simulate. See Filter Search 4: Curve selection.
Opening from the left Workspace
Click “Duty Simulation” in the left Workspace to open the most recent simulation directly (the record is saved in the current browser). If you have never run a simulation, the guide page “How to start a duty simulation” is shown, explaining how to open a simulation from Data Search and from Filter Search and that “The last simulation is remembered”, with two buttons, “Go to Data Search” and “Go to Filter Search”.
Other entry points
“Simulate” in each row of the Private models list: uses the BEP at the curve's rated speed as the design point, clear water, no piping.
The “Simulate” button of saved selections in Saved Selections and Projects: opens in a new tab with the Filter Search duty as it was saved.
Page layout
Tab row and Status
The top of the page shows, in order: the pump size and curve name; the tag when opened from Data Search; “Series × n” or “Parallel × n” for multiple pumps; “Impeller trim x%” when the impeller trim is below 100%; and “Wear (head decay) x%” when wear is applied. The operating status is on the far right: the dot color indicates the status, and the text is the first warning, or “Operating normally” when there are no warnings.
Dot color · Meaning
Green · Operating normally, or informational messages only
Orange · Outside the allowed BEP range, efficiency unavailable, low NPSH margin, outside the preferred operating region
Red · Cannot deliver, runaway flow, no system curve, cavitation risk, risk of pipe deposition, flow too low or too high
Three columns and lower area
Left: the “Operating Parameters” panel with all adjustable parameters.
Center: the “Pump & System Curves” chart.
Right: the “Readings” panel and the list of warnings.
Below: the analysis tabs (Performance curves, Speed control, etc.), plus “Piping Diagram” and “Energy Grade Line” when piping is present.
Every parameter change triggers an automatic recalculation; if a calculation takes longer than about 0.4 seconds, “Calculating” is shown on the chart and a spinning circle appears to the right of the Readings panel title.
Top-right buttons
“Add to comparison”, “Export CSV” and “Print”; see Comparison tab and Export and print.
Units
The flow and head units follow the unit system of the page the simulation was opened from: L/s, m³/min, m³/h or USGPM, with head in m, or ft (for USGPM). When opened from a private model, the units are m³/h and m. Power is always in kW, pipe diameter in mm and velocity in m/s.
Operating Parameters
Parameter groups
From top to bottom, the “Operating Parameters” panel contains: speed (or impeller diameter) with the “Sweep speed” and “Reset to design” buttons, impeller trim, wear and valve opening; then groups under subheadings: “Slurry” (Cw, d50), “Piping” (when piping is present) or “System” (static head ratio when there is no piping), “Operating conditions” (level variation, fluid temperature, altitude), and “Pumps”. Parameters and groups whose display conditions are not met do not appear.
Speed
A slider that adjusts the pump speed, in r/min, in steps of 1 r/min.
Range: from the lowest to the highest speed line in the curve family.
Default: the speed required to pass through the design point (marked “Design” on the slider); the rated speed if there is no design point.
How to use: after dragging, the operating point moves along the system curve and the readings refresh in real time. The design speed changes with impeller trim and wear: after trimming or wear, a higher speed is needed to reach the same design point.
Impeller Diameter (Operating Parameters)
When the curve is organized by impeller diameter (same speed, different diameters), the first slider becomes the impeller diameter, in mm, in steps of 0.5 mm, ranging from the smallest to the largest diameter in the curve, and “Speed” in the readings and tables also changes to “Impeller Diameter”. In this case “Impeller trim” is not shown (the diameter slider itself is the trim).
Sweep speed
After you click “Sweep speed”, the speed changes back and forth automatically between the lowest and highest values (one step every 0.12 seconds, about 60 steps each way), so you can watch the operating point slide along the system curve. The button changes to “Stop”; click it again to stop.
Reset to design
Restores all operating parameters to their initial values when the simulation was opened (speed back to the design speed, valve fully open, trim 100%, wear 0, etc.) and stops the sweep.
Impeller trim
The performance after the impeller outside diameter is trimmed, expressed as a percentage, with the diameter ratio shown alongside (e.g. “D×0.950”).
Range: 70%–100%, in steps of 0.5%; default 100% (no trim).
Calculation: the clear-water curve of each pump is converted with the trimming affinity laws, where t is the trim ratio:
Q' = Q × t
H' = H × t²
Efficiency loss: after trimming, the efficiency is reduced by an empirical amount (percentage points):
Δη = 15 × (1 − t)^1.5
Trim ratio t · Efficiency reduction
95% · About 0.2 percentage points
90% · About 0.5 percentage points
80% · About 1.3 percentage points
70% · About 2.5 percentage points
Effect on results: the pump curve shifts down and to the left as a whole, and the flow, head and power at the operating point decrease. With heavy trimming, the actual efficiency loss may be greater than the empirical value.
Trim needed to meet the duty point
The hint below the impeller trim slider: “Trim to x% to meet the duty point”. This is the trim ratio at which, at the current speed and wear, the pump curve passes exactly through the design point (system flow, slurry head). Click “Apply” next to it to set the trim slider to that value.
Shown only when trimming is needed (below about 99.9%).
Not shown when the design point cannot be reached even without trimming at the current speed, or when trimming below 50% would be needed.
Wear (head decay)
Simulates the drop in pump head after wear of the impeller and liners.
Range: 0%–30%, in steps of 1%; default 0.
Calculation: at wear w, the flow is unchanged, the head drops proportionally, and the efficiency also decreases:
H' = H × (1 − w)
η' = η × (1 − 0.8 × w)
Worked example (hypothetical figures): with w = 10% and an original efficiency of 70%, η' = 70 × 0.92 = 64.4%.
Effect on results: the operating point moves toward lower flow; when efficiency, NPSHr and %BEP are read, the head is restored by ÷(1 − w) to the unworn curve for the lookup.
Valve Opening
The opening of the control valve at the end of the discharge pipe, in %. Shown only when piping is present.
Range: 5%–100%; default 100% (fully open).
Effect on results: as the opening decreases, the system curve becomes steeper, and the operating point flow decreases while the head increases. A valve symbol appears at the outlet in the piping diagram.
Added K
“Added K = …” shown below the valve opening: the local resistance coefficient produced by the valve, added as a fitting to the last discharge pipe section. The relationship between the opening x (0–1) and K is an illustrative characteristic:
K = 0.5 × (1 / x² − 1)
Valve loss hv = K × v² / (2g)
Opening · K
100% · 0
50% · 1.5
25% · 7.5
10% · 49.5
5% · 199.5
Actual characteristics vary greatly between valves; the simulation result depends only on the K value. If you know the actual K value of your valve, you can use this table to work back to the corresponding opening.
Cw
The concentration of solids in the slurry by weight, in %. Shown only when the slurry type in Filter Search is “Single Solid” and the known pair of values includes Cw (S + Cw or Sm + Cw).
Range: 0%–70%, in steps of 0.5%; default is the value from Filter Search.
Effect on results: Cw changes the slurry specific gravity Sm, the head ratio Hr and the efficiency ratio Er, and therefore the slurry head, power and settling velocity.
d50
The median particle size of the solids, in µm. Same display condition as Cw.
Range: 10–5000 µm, in steps of 10; default is the value from Filter Search.
Effect on results: the larger the particle size, the higher the settling velocity (the pipe deposits more easily), and Hr/Er are usually smaller.
Discharge ID
The inside diameter of the first discharge pipe section, in mm. Shown only when piping is present (same below).
Range: 40% of the initial value (not less than 10 mm) to 2 times the initial value.
Effect on results: as the diameter decreases, the velocity increases and the friction loss rises roughly with the fifth power, making the system curve steeper; at the same time, the ratio of velocity to settling velocity increases.
Discharge length
The length of the first discharge pipe section, in m.
Range: 1 m to 4 times the initial value (at least 50 m).
Effect on results: the longer the pipe, the greater the friction loss and the steeper the system curve.
Discharge static head
The elevation of the discharge outlet relative to the pump centerline, in m (or ft).
Range: 0 to 2.5 times the initial value (at least 60 m), in steps of 0.5.
Effect on results: the whole system curve shifts up or down.
Suction static head
The elevation of the sump liquid level relative to the pump centerline, in m; positive means flooded suction (level above the pump), negative means suction lift. Shown only for horizontal pumps.
Range: −10 to 20 m, in steps of 0.5.
Effect on results: affects the system static head and NPSHa; the sump level in the piping diagram changes accordingly.
Pipe roughness
A roughness multiplier for aged or scaled pipes (tooltip “Increase for aged or scaled pipes”).
Range: ×1 to ×20, in steps of 0.5; default ×1 (new pipe).
Calculation: applies to the suction pipe and all discharge sections. When friction is calculated with the Darcy formula, the absolute roughness is multiplied by this factor f; with the Hazen-Williams formula, the C value is divided by f^0.15. For example, at f = 4 a pipe with C = 140 becomes about 114.
Static head ratio
Shown only when there is no piping (replacing the piping parameter group): the proportion of the design head that is static head. Tooltip “When no piping is entered, the share of design head that is static head (higher = flatter system curve)”.
Range: 0%–90%, in steps of 5%; default 0 (the system curve is a parabola through the origin).
Calculation: see Source of the system curve.
Level variation
The amplitude by which the suction or discharge level fluctuates up and down, ± m.
Range: 0 to 20 m, in steps of 0.5; default 0.
Effect on results: when greater than 0, the system curve is shifted up and down by this amplitude; two pink dashed lines and two triangular operating points appear on the chart, and the “Operating range” tab appears.
Fluid temperature
The temperature of the pumped fluid, in ℃. Shown only when piping is present and the pump is horizontal.
Range: 0–95 ℃; default is the value from Filter Search (20 ℃ if none).
Effect on results: the higher the temperature, the higher the saturated vapor pressure and the smaller the NPSHa.
Altitude
The altitude of the pump station, in m. Same display condition as fluid temperature.
Range: 0–5000 m, in steps of 50; default is the value from Filter Search.
Effect on results: the higher the altitude, the lower the atmospheric pressure and the smaller the NPSHa.
Note: If NPSHa was entered directly in Filter Search, the simulation uses that fixed value, and temperature and altitude no longer affect NPSHa.
Pumps and Arrangement
Three buttons, “Single”, “Series” and “Parallel”; after choosing series or parallel, a box for the number of pumps appears (2–8 pumps). Shown only for horizontal pumps.
Series: every pump has the same flow; total head = head per pump × number of pumps.
Parallel: every pump has the same head; total flow = flow per pump × number of pumps.
Effect on results: the pump curve on the chart is the combined curve; in the readings, flow and slurry head are system totals, efficiency, NPSHr and %BEP are calculated per pump, and power is given both per pump and in total. The “Multiple pumps” tab appears.
Source of the system curve
With piping entered
When discharge piping (inside diameter and length) has been entered in the duty, the system head is calculated point by point from the piping:
H_system(Q) = static head + head equivalent of terminal pressure + friction loss of each section + local loss of each fitting (incl. valve K) + velocity head
The calculation is the same as for the system head in Filter Search 2: Head details; friction is calculated with the Darcy or Hazen-Williams method selected in the duty, and the valve is included as an additional fitting in the last discharge section.
Without piping
The system curve is estimated as a quadratic curve through the design point; “No piping entered: system curve estimated as a parabola through the design point” is shown next to the chart title, and the system curve is drawn as a dashed line:
Hs0 = static head ratio × H_design
H_system(Q) = Hs0 + (H_design − Hs0) × (Q / Q_design)²
Worked example (hypothetical figures): Q_design = 100 L/s, H_design = 40 m. With a static head ratio of 0, at Q = 80 L/s H_system = 40 × 0.64 = 25.6 m; with a ratio of 50%, Hs0 = 20 m and H_system = 20 + 20 × 0.64 = 32.8 m. The larger the ratio, the flatter the system curve and the more the flow changes when the speed changes.
Without a duty
When there is neither piping nor a design duty (e.g. when opened from a private model or from a Data Search without a duty), the BEP at the curve's rated speed is used as the design point to estimate the system curve, and “No duty or piping: system curve estimated as a parabola through the BEP” is shown next to the chart title. For multiple pumps, the design point is combined by the number of pumps (parallel: flow × n; series: head × n).
Solving the operating point
The operating point is the intersection of the (combined) pump slurry curve and the system curve: starting from low flow, the interval where the pump head changes from above to below the system head is found and then refined by bisection. The system curve is drawn only up to 1.3 times the shut-off head at maximum speed, to avoid stretching the vertical axis too far.
Pump & System Curves chart
The chart in the center, with flow on the horizontal axis and slurry head on the vertical axis. Hovering shows a crosshair and the values of each curve; click a legend item to hide or show the corresponding curve.
Pump (slurry)
Solid green line: the pump slurry head curve at the current speed (and trim, wear, number of pumps), = water head × Hr; the combined curve for multiple pumps. The operating point lies on this line.
Pump (water)
Dotted blue line: the clear-water head curve at the same speed (not multiplied by Hr).
System (legend)
Red line: the head required by the piping system. Solid when piping is present, dashed when estimated.
Operating point (legend)
A dot with a ripple, labeled with flow and head. Its color matches the operating status: green normal, orange caution, red warning.
Design point
Gray hollow circle: the design flow and slurry head of the duty (system totals). The distance between the operating point and the design point shows at a glance how far the current parameters deviate from the design.
BEP (legend)
Blue diamond: the point of highest efficiency at the current speed.
Speed range
Two light gray dashed lines: the pump slurry curves at the lowest and highest speeds, showing the range that speed control can cover.
Preferred operating region
The light green vertical band around the BEP diamond, labeled “Preferred operating region”: 70%–120% of the BEP flow at the current speed.
Level variation band
When the level variation is greater than 0: the two pink dashed lines are the system curve ± the variation amplitude, and the two pink triangles are the corresponding two operating points.
Settling flow
Brown vertical dashed line, labeled “Settling flow”: the flow at which the velocity in the first discharge section equals the settling velocity. When the operating flow is to the left of it, the pipe is at risk of deposition.
Readings
The “Readings” panel on the right. “-” is shown when there is no value.
Flow (Readings)
The total system flow at the operating point (the sum of all pumps in parallel).
vs design
The small text below the flow, “±x% vs design”:
vs design = (Q_operating ÷ Q_design − 1) × 100%
It turns orange when the deviation exceeds ±10%.
Slurry head
The system slurry head at the operating point (the sum of all pumps in series), i.e. the vertical coordinate of the intersection of the pump slurry curve and the system curve.
Water head (per pump)
The clear-water head of each pump:
H_water = slurry head per pump ÷ Hr
In series, slurry head per pump = slurry head ÷ number of pumps.
Speed (Readings)
The current speed, in r/min (impeller diameter in mm for diameter curve sets).
Efficiency (Readings)
The efficiency of each pump at the operating point, in %. It is interpolated on the curve's efficiency surface at the flow per pump and the clear-water head (after wear restoration), and then the following deductions are applied in turn:
η = (η_curve × (1 − 0.8 × wear) − trim efficiency loss) × (1 − seal efficiency loss)
Seal efficiency loss: 3% for a centrifugal seal (expeller) (plus another 9% with a differential impeller); for a mechanical seal it is looked up from a table by speed and pump discharge size; no deduction for a gland seal. When the operating point is outside the efficiency data range, “-” is shown.
Shaft power
“Shaft power” is shown for a single pump and “Shaft power (per pump)” for multiple pumps, in kW:
P_per pump = Sm × Q_per pump (L/s) × H_slurry per pump (m) × 0.981 ÷ (η (%) × Er)
For froth slurry, Sm is further divided by the froth volume factor. Worked example (hypothetical figures): Q = 100 L/s, H_slurry = 30 m, Sm = 1.3, η = 70%, Er = 0.9, P = 1.3 × 100 × 30 × 0.981 ÷ (70 × 0.9) ≈ 60.7 kW.
Total power
Shown for multiple pumps: shaft power per pump × number of pumps.
%BEP
The operating point flow as a percentage of the best efficiency point flow; the allowed range set in the duty is given in parentheses (e.g. “(70–120)”), and the value turns orange when outside it.
Calculation:
1. Per pump: in parallel, the flow per pump Q_per pump = total flow ÷ number of pumps is used; in series, the head per pump is used.
2. Slurry head to water head: H_water = slurry head per pump ÷ Hr.
3. Wear restoration: H' = H_water ÷ (1 − wear), restoring the worn point to the original curve.
4. Conversion along the affinity parabola: compared with the BEP at the curve's rated speed.
%BEP = Q_per pump ÷ ( Q_BEP × √(H' ÷ H_BEP) ) × 100
Q_BEP and H_BEP are the best efficiency point at the curve's rated speed. Impeller trim needs no separate correction: by the affinity laws, an impeller with trim ratio t at speed n performs the same as the original impeller at speed n·t, so the same (Q, H) point can be compared directly on the original curve.
Worked example (hypothetical figures): Q_BEP = 100 L/s, H_BEP = 40 m; 2 pumps in parallel, total flow 180 L/s, slurry head 33 m, Hr = 0.9, wear 10%. Q_per pump = 90 L/s; H_water = 33 ÷ 0.9 ≈ 36.67 m; H' = 36.67 ÷ 0.9 ≈ 40.74 m; √(40.74 ÷ 40) ≈ 1.009; %BEP = 90 ÷ 100.9 × 100 ≈ 89%.
%BEP vs BEP at current speed
When the operating point flow is exactly equal to the “BEP at current speed” flow in the readings, %BEP is not necessarily exactly 100%, because the two use different references:
%BEP is referenced to the BEP at the curve's rated speed, converted to the operating head along the affinity parabola (H ∝ Q²); “BEP at current speed” is the point of highest efficiency found directly along the current speed curve. The iso-efficiency islands of a real pump do not move strictly along the affinity parabola, and the difference grows the farther the speed is from rated.
“BEP at current speed” is the highest-efficiency point among about 50 calculation points on the current curve, so it has a certain spacing.
In parallel, the flow of “BEP at current speed” is the total system flow on the combined curve, whereas %BEP is calculated with the flow per pump.
Therefore the “Preferred operating region” band on the chart (70%–120% of the BEP at current speed) and the warning “Operating point is outside the preferred operating region” based on %BEP may not match exactly near the boundaries. For engineering judgment, %BEP is authoritative.
NPSHr
The net positive suction head required by each pump at the operating point, interpolated on the curve's NPSHr surface at the flow per pump and the clear-water head (after wear restoration).
NPSHa
The net positive suction head available from the installation. If NPSHa was entered directly in Filter Search, that value is used; otherwise, for a horizontal pump with a suction pipe entered, it is calculated as follows (flow per pump):
NPSHa = (Ha − Hv) ÷ Sm + suction static head − suction pipe losses (entrance + friction + fittings) − slurry column correction
Ha is the local atmospheric pressure head (decreasing with altitude, about 10.34 m at sea level), and Hv is the saturated vapor pressure head at the fluid temperature. In all other cases “-” is shown.
NPSH margin
NPSH margin = NPSHa − NPSHr
Red below 0, orange between 0 and 1 m, green above 1 m.
Hr / Er
The head ratio Hr (slurry head ÷ water head) and efficiency ratio Er (slurry efficiency ÷ water efficiency), to three decimal places, derived from the HR/ER method and slurry parameters selected in Filter Search; both are 1.000 for a clear-water duty. See Filter Search 1: Fluid details.
Sm
Slurry specific gravity (relative density of the mixture), to three decimal places; 1.000 for clear water.
Max power over full curve (per pump)
The maximum shaft power per pump calculated along the whole pump curve at the current speed, in kW. Used for the motor check: when the operating flow changes because of level, valve or other changes, the power may rise to this value.
BEP at current speed
The flow and efficiency at the point of highest efficiency on the current speed curve, e.g. “120.5 m³/h · 68.2%”.
Status and warnings
Warnings are shown below the readings (red list); the first one is also shown in the status area at the top right of the page.
Operating normally
There are no warnings at all.
This curve has no usable speed curve set
The curve lacks a speed or diameter curve set usable for simulation, so it cannot be simulated. This message also appears for other users' private curves.
Shut-off head is below the static head; the pump cannot deliver
At the current speed, the pump head at zero flow does not exceed the system static head, so there is no intersection. Increase the speed, reduce the static head, or reduce trim or wear.
Pump and system curves do not intersect; operation runs out past the curve end
The system resistance is too low, and the end of the pump curve is still above the system curve. The operating point is taken at the rightmost end of the curve; the actual flow will exceed the curve range, with a risk of overload and cavitation. You can reduce the valve opening or lower the speed.
NPSHa is below NPSHr: cavitation risk
The NPSH margin is negative. Raise the suction level, enlarge the suction pipe diameter, or reduce the speed or flow.
Operating point is outside the allowed BEP range
%BEP is outside the minimum/maximum BEP percentage set in Filter Search.
Velocity in some pipe section is below settling velocity: risk of deposition
The velocity in at least one pipe section is below the settling velocity of that section (the critical velocity for non-Newtonian fluids). This item is not checked when the flow runs away.
Operating point is outside the efficiency surface; efficiency/power unavailable
The operating point is outside the curve's efficiency data range; efficiency and power show “-”.
No design flow/head to estimate a system curve
There is no piping, and no design duty or BEP is available, so no system curve can be established.
NPSH margin is low (below 10% of NPSHr or 0.6 m); allow sufficient margin
NPSHa is greater than NPSHr, but NPSHa < 1.1 × NPSHr, or NPSHa − NPSHr < 0.6 m.
Operating point is outside the preferred operating region (70%–120% BEP)
%BEP is between 50% and 70% or between 120% and 125%.
Flow below 50% BEP; risk of recirculation, vibration and heating
%BEP < 50%.
Flow above 125% BEP; risk of cavitation and excessive power
%BEP > 125%.
System curve estimate notice
“No piping entered: system curve estimated as a parabola through the design point” or “No duty or piping: system curve estimated as a parabola through the BEP”, shown next to the chart title (small orange text); not counted as a warning.
Operating risks
The “Operating risks” card below the readings card checks 7 risks of the current operating point against engineering rules of thumb: operating region, suction specific speed, NPSH margin ratio, blade passing frequency, radial thrust, critical speed margin and tip speed. Each item shows a level tag, and the items are sorted by severity (risks first). Next to the card title is the overall rating: if any item is “Risk”, the overall rating is Risk; otherwise, if any item is “Caution”, it is Caution.
These criteria are suitable for selection and comparing alternatives; they cannot replace factory tests and field vibration measurements. They update in real time with the operating point as you drag the speed, valve, trim and other parameters.
Risk levels
OK (green): within the recommended range.
Caution (orange): operation is possible, but vibration, wear or NPSH margin is worse than recommended; keep an eye on it over the long term.
Risk (red): not suitable for long-term operation here, or the combination of design parameters is prone to resonance.
Info (blue): only a value is given, with no upper limit to compare against (e.g. tip speed when no impeller material is selected).
No data (gray): data required for the calculation is missing; the explanation states what needs to be added.
Operating region
Judged by which range the operating point's %BEP falls in:
Below the minimum continuous flow: Risk. Suction and discharge recirculation, vibration and temperature rise are significant; not suitable for long-term operation.
Minimum continuous flow to the lower limit of the allowable region: Caution (part load).
Lower limit of the allowable region to 70%: Caution.
70%–120%: OK (preferred operating region).
120%–125%: Caution (high flow; NPSHr and power rise).
Above 125%: Risk (beyond the allowable region).
The lower limit of the allowable region is generally 50% BEP; it is raised to 60% when the suction specific speed exceeds 11000. If the minimum continuous flow is not entered, it is estimated from the suction specific speed (marked “(est.)”): 25% for Nss ≤ 9000, 35% for ≤ 11000, 50% for ≤ 13000, and 60% above that; 30% when NPSHr data is missing.
On the chart, the allowable region is marked with a light orange background and the minimum continuous flow with a red dotted line; the preferred operating region is still the light green background. The %BEP colors in the speed control, multiple pumps and operating range tables follow the same boundaries.
Suction specific speed
Calculated from the flow at the BEP at the current speed (half for a double-suction impeller) and the NPSHr at that point: Nss = n·√Q / NPSHr^0.75, given in both US units (r/min, gpm, ft) and metric units (r/min, m³/s, m). In US units, above 11000 is Caution and above 13000 is Risk. The higher the suction specific speed, the earlier recirculation appears at low flow and the narrower the allowable region. If the curve has no NPSHr data, “No data” is shown.
NPSH margin ratio
NPSHa ÷ NPSHr. Recommended minimum: 1.1 when the operating point is within the preferred operating region, 1.3 outside it; add 0.2 when the suction specific speed exceeds 11000. Below 1 is Risk; below the recommended minimum is Caution. NPSHa is required: enter the suction piping in Filter Search, or enter NPSHa directly.
Blade passing frequency
Running frequency = speed ÷ 60, blade passing frequency = number of vanes × speed ÷ 60; the 2× frequency is also given. High peaks at these two frequencies in a field vibration spectrum are often related to off-design operation or too small a gap between the impeller and the cutwater.
Rotor–stator interaction is also checked:
Diffuser casing: Risk (prone to resonance) when the number of vanes Z and the number of diffuser vanes Zd satisfy m·Z = ν·Zd (m = 1, 2; ν = 1, 2, 3); Caution when · m·Z − ν·Zd · = 1 or the two have a common divisor.
Double volute with an even number of vanes: Caution (both cutwaters are hit by the vanes simultaneously).
Radial thrust
Estimated with the Stepanoff formula: F = K × slurry density × g × head per pump × impeller outside diameter × outlet width. The coefficient K varies with %BEP and casing type: for a single volute it is smallest near the BEP and largest at shut-off; for a double volute it is about one quarter of the single volute value; diffuser/annular casings use a small constant. The farther from the BEP, the greater the radial thrust, and shaft deflection and bearing loads rise accordingly. Requires the impeller outside diameter and outlet width.
Critical speed margin
The relative difference between the running speed and the 1st critical speed. Below 10% is Risk, below 20% is Caution. You must enter the 1st critical speed yourself (from manufacturer data or a rotordynamic calculation); for vertical pumps, the critical speed check can be done in Filter Search step 6.
Tip speed
π × impeller outside diameter × speed ÷ 60. For speed curve sets, the outside diameter is already converted by the impeller trim ratio; for diameter curve sets, the diameter on the slider is used. When an impeller material has been configured in Filter Search, the tip speed is compared with that material's upper limit: exceeding it is Risk, exceeding 90% of it is Caution; when there is no material limit, only the value is shown (Info).
Design data
On the right of the card are the design parameters used in the calculation. Impeller vanes, impeller diameter and impeller outlet width directly show the values of the current curve and impeller in the impeller data (or the private model), and the source is noted below the input box (from impeller data / from private model). When there is no data, the input box is empty and “unknown, please enter” is shown. When you open the simulation with a different curve or impeller, these items are automatically replaced with the data of the new impeller.
Changed values are marked “Edited” below the box; click “Restore impeller data” to return to the values in the impeller data. Changing a value back to the same as the impeller data also counts as unedited.
Impeller vanes: the number of impeller vanes.
Casing type: Single volute, Double volute, Diffuser / annular; affects the radial thrust coefficient and the rotor–stator interaction check.
Diffuser vanes: appears when the casing type is a diffuser.
Impeller diameter (mm): the untrimmed outside diameter; shown only for speed curve sets. When the impeller trim is below 100%, “Current OD after trim: xxx mm” is shown below, and radial thrust and tip speed are calculated with the trimmed outside diameter.
Impeller outlet width (mm): used for radial thrust.
Running speed (r/min): shown only for diameter curve sets; speed curve sets use the slider speed directly.
Min. continuous flow (%BEP): if left empty, estimated from the suction specific speed.
1st critical speed (r/min).
Double suction: when ticked, the suction specific speed is calculated with half the flow per suction eye.
Changed values are stored per curve and impeller in this browser, and are filled in automatically the next time you open the same curve with the same impeller; if you change the impeller, the data of the new impeller is used. “Reset” clears all entries. The printed report includes the operating risks section.
Piping Diagram
An (animated) diagram shown when piping is present; from left to right: sump, suction pipe, pump, the discharge pipe sections, and the outlet.
Pipe width and color
The pipe width is proportional to the inside diameter. The color depends on the ratio of the velocity v to the settling velocity vs:
Color · Condition
Green · v ≥ 1.1 vs
Orange · vs ≤ v < 1.1 vs
Red · v < vs; risk of deposition
Gray · No settling velocity data
The speed of the dashes flowing in the pipe is proportional to the velocity, and the pump impeller rotates faster or slower with the speed.
Section labels
Above each section, “Sect.n Øxxx · v m/s” gives the section number, inside diameter (mm) and velocity; below it are “Settling vel. x” (“Critical vel. x” for non-Newtonian fluids, m/s) and “Loss x” (friction + fitting losses of that section, in the same unit as the head). The suction pipe is labeled only with the inside diameter, velocity and settling velocity, without a section number or loss.
Outlet and valve
The top of the vertical outlet pipe is labeled “Outlet Hd x”, i.e. the discharge static head. When the valve opening is less than 100%, a red valve symbol is shown at the outlet.
Energy Grade Line
The “Energy Grade Line” chart shown when piping is present: horizontal axis “Length along line (m)”, vertical axis “Total head (m slurry)”, with the pump centerline as 0.
For a horizontal pump with a suction pipe, it starts at the sump level (= suction static head) and drops along the suction pipe by the entrance loss (0.5 times the velocity head) and the suction pipe losses; in other cases it starts at 0 at the pump inlet;
At “Pump” it jumps up by the pump head;
Along each discharge section (labeled “Sect.n”) it drops section by section by the friction and fitting losses, ending at “Outlet”;
The brown horizontal dashed line “Hd x” is the discharge static head. The part of the end point above this line is the residual head at the outlet.
Performance curves tab
The performance of each pump versus flow at the current speed:
Solid blue line “Efficiency” (left axis, 0–100%);
Solid red line “Shaft power (per pump)” (right axis, kW);
Dashed brown line “NPSHr” (far right axis);
The light green vertical band is the preferred operating region, and a green vertical dashed line marks the “Operating point”.
Three lines of information below the chart:
BEP at current speed info
“BEP at current speed: flow · head · efficiency”.
Preferred operating region range
“Preferred operating region (70%–120% BEP): x – y”, i.e. 0.7–1.2 times the BEP flow at the current speed.
Max power over full curve info
Same as Max power over full curve (per pump) in the readings.
Speed control tab
7 evenly spaced speeds between the lowest and highest speeds are taken, plus the current speed (if it is within 3% of the speed range of one of those steps, that step is replaced by the current speed), and the operating point is found for each.
Speed control chart
The horizontal axis is speed (or impeller diameter); green “Flow” (left axis), red “Total power” (kW axis) and dashed blue “Efficiency” (% axis); the dots are the calculated values for each step.
Speed control table
Column · Meaning
Speed · The speed of each step; the current speed is preceded by ▶
Flow · The operating flow at this speed
Slurry head · The operating head at this speed
Eff % · Efficiency per pump
Total power kW · Total for all running pumps
%BEP · Green 70%–120%, orange 50%–70% or 120%–125%, red <50% or >125%
Status · Messages such as cannot deliver or runaway flow at this speed
Multiple pumps tab
Shown for multiple pumps in series or parallel: “Operating points as pumps are brought online one by one, at the current speed and system curve.”
Pump-by-pump table
Column · Meaning
Pumps running · k / n, with k from 1 to the total number of pumps
Flow · System flow with k pumps running
Slurry head · System head with k pumps running
Flow per pump · Flow ÷ k in parallel; equal to the system flow in series
Eff % · Efficiency per pump
Total power kW · Total for k pumps
%BEP · Per pump; same coloring rules as the speed control table
Status · Messages such as cannot deliver or runaway flow
When fewer parallel pumps are running, the flow per pump often increases substantially; watch %BEP and NPSH.
Operating range tab
Shown when the level variation is greater than 0: “Range of operating points when suction/discharge level variations change the static head.”
Operating range table
Three rows: “Min static head” (system curve shifted down by the variation amplitude, maximum flow), “Current”, and “Max static head” (system curve shifted up, minimum flow); the columns are flow, slurry head, Eff %, total power kW, %BEP and NPSHr.
Motor & energy tab
Motor check
The maximum power over the full curve is multiplied by the safety factor, and the standard motor rating not smaller than that value is selected (“Max power over the full curve × safety factor, rounded up to the next standard motor rating.”). The standard ratings are: 0.12, 0.18, 0.25, 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90, 110, 132, 160, 185, 200, 220, 250, 280, 315, 355, 400, 450, 500, 560, 630, 710, 800, 900, 1000, 1120, 1250, 1400, 1600, 1800, 2000, 2240, 2500, 2800, 3150, 3550, 4000, 4500, 5000 kW. Above 5000 kW, “-” is shown.
Power safety factor
The factor by which the motor power exceeds the pump's maximum shaft power (Service Factor).
Range: 1–1.5, in steps of 0.05; default 1.15.
Based on max power at current speed
Required power = max(shaft power per pump at operating point, max power over full curve at current speed) × safety factor
Shown as “required kW → standard kW”. Worked example (hypothetical figures): 60 kW at the operating point, 66 kW maximum over the full curve, factor 1.15: required 75.9 kW → 90 kW selected.
Based on max power at maximum speed
Required power = max shaft power per pump over full curve at maximum speed × safety factor
Used for motor selection when the pump may be run at a higher speed in the future.
Energy & cost
The following three inputs (together with the currency symbol) are saved in this browser and reused next time.
Annual operating hours
Operating hours per year, h. Range 100–8760, in steps of 100; default 6000.
Electricity price (per kWh)
Electricity price per kWh, range 0–100, up to 3 decimal places; default 0.7. The small box on the right is the currency symbol, default “¥”, which can be changed to another symbol.
Motor efficiency source
Selects how the motor efficiency used in the input electrical power is obtained:
Option · Description
Manual entry (default) · Uses the fixed value in the “Motor efficiency” box below; the same calculation as before
Per motor · Select a motor and take the efficiency from its load characteristic at each pump's load factor; see Per motor
Motor efficiency
Shown when “Manual entry” is selected. Motor efficiency, %, range 50–99; default 95.
Per motor
After “Per motor” is selected, a “Selected motor” section appears below:
Motor selection: by default, an IE3 standard motor whose rating follows the recommended power in “Motor check” (the larger of the values at the current speed and at maximum speed), with the pole count matched to the pump speed: for direct coupling, the pole count whose rated speed is within 5% of the pump speed; for VFD direct coupling, the largest pole count whose synchronous speed is not below the pump speed; otherwise 4 poles. You can change it to another efficiency class, power, poles, voltage or frequency, or to a motor from “My Motor Library”; a motor chosen by hand applies only to the current pump (model and curve), and after switching to another pump it returns to automatic recommendation. When the recommended power exceeds 1000 kW, it is outside the standard motor range and the message “Required power exceeds the standard motor range (1000 kW). Please enter a high-power motor in My Motor Library.” is shown; in this case the motor efficiency entered by hand is still used for the calculation. After a change, “Restore auto recommendation” is shown. See Motor Selection & Analysis.
Operating data: load factor, motor efficiency, power factor and current, overall unit efficiency (pump × drive × motor), allowable pump shaft power (rated × service factor × drive efficiency; for VFD operation at reduced speed, further multiplied by the speed ratio) and maximum shaft power over the full curve.
Check results: messages such as the full-curve overload check failing, light load, and speed mismatch with direct coupling; see Operating analysis messages.
Detailed analysis & start-up check →: opens Motor Selection & Analysis with the current simulation's shaft power, speed, drive type, impeller diameter and pump power curve.
With “Per motor”:
Load factor per motor = shaft power per pump ÷ drive efficiency ÷ rated motor power
Electrical input power = number of pumps × shaft power per pump ÷ drive efficiency ÷ motor efficiency at this load factor (with VFD, also ÷ VFD efficiency)
The two rows in “Throttling vs VFD” below also take the motor efficiency at their own load factors. The power chart on the “Performance curves” tab gets a dashed line “Motor x kW limit”, which is the allowable pump shaft power; the part of the power curve above this line overloads the motor. The drive type is taken from “Drive Type” in step 5 of Filter Search; when opened from Data Search, direct coupling is assumed.
Electrical input power
Electrical input power = total shaft power ÷ motor efficiency
Annual consumption
Annual consumption (kWh) = electrical input power × annual operating hours
Annual electricity cost
Annual electricity cost = annual consumption × electricity price
Specific energy
Electricity consumed per 1 m³ of fluid pumped:
Specific energy (kWh/m³) = annual consumption ÷ (flow (m³/h) × annual operating hours)
Worked example (hypothetical figures): total shaft power 60 kW, motor efficiency 95%, input 63.2 kW; at 6000 h the annual consumption is about 378,900 kWh; at a price of 0.7 the annual cost is about 265,300; at a flow of 360 m³/h the specific energy is about 0.175 kWh/m³.
Throttling vs VFD
Titled “Same flow x: valve throttling vs VFD”, this compares two ways of reaching the current operating flow:
Control method · Speed · Pump head · Notes
Fixed speed + valve throttling · Rated speed (maximum speed if the rated speed cannot reach the flow) · The pump head at this flow and speed; the excess head is consumed by the valve · Electrical input power = shaft power ÷ motor efficiency
VFD speed control (valve fully open) · The speed at which the pump head just equals the system head with the valve fully open · System head with the valve fully open · Electrical input power = shaft power ÷ motor efficiency ÷ VFD efficiency (taken as 97%)
The table columns are control method, speed, pump head, total power kW and electrical input power kW. Below the table:
Annual savings (kWh) = (throttling electrical input power − VFD electrical input power) × annual operating hours
Saving ratio = (1 − VFD electrical input power ÷ throttling electrical input power) × 100%
Shown as “VFD saves x kWh per year, about ¥ y (z% saving)”.
VFD comparison notes
“Not comparable at this duty (rated speed cannot reach this flow, or efficiency data is missing).”: the required head cannot be reached even at maximum speed, or efficiency data is insufficient.
“VFD is at minimum speed; some throttling is still required.”: even at the curve's lowest speed the pump head is still higher than the system requires, so the VFD case is calculated at the lowest speed.
Pump-trip surge tab
Estimates the upper limit of the pressure surge in the discharge pipe for a sudden pump trip (instantaneous flow stoppage) (Joukowsky formula). Without discharge piping, “Enter the discharge piping to estimate.” is shown.
Pipe material
The pipe material, which determines the pipe wall modulus of elasticity E:
Pipe material · E
Steel · 207 GPa
Ductile iron · 170 GPa
HDPE · 0.8 GPa
PVC · 3 GPa
Concrete · 30 GPa
Rubber-lined hose · 0.05 GPa
Default: steel.
Wall thickness
Pipe wall thickness e, mm, range 1–100; default 8.
Valve closing time
The time T for the valve or check valve to go from fully open to fully closed, s, range 0–600, in steps of 0.5; default 0 (instantaneous closure).
Wave speed
The propagation speed a of the pressure wave in the pipe, m/s:
a = 1 / √( ρ × (1/K + D / (E × e)) )
ρ = 1000 × Sm (kg/m³), K = 2.2 GPa (bulk modulus of the liquid), and D is the inside diameter of the first discharge section. The softer the pipe material and the thinner the wall, the lower the wave speed.
Pipe period 2L/a
The time for the pressure wave to travel there and back once, s; the total discharge pipe length L is given in parentheses:
Tc = 2L / a
Max pressure change
ΔH = a × v / g
v is the operating velocity in the first discharge section. When the valve closing time T is longer than the pipe period, the value is reduced proportionally: ΔH × Tc / T. The converted pressure is also shown (≈ x kPa, = ΔH × ρ × g ÷ 1000).
Worked example (hypothetical figures): steel pipe, D = 200 mm, e = 8 mm, Sm = 1, a ≈ 1318 m/s; at v = 2 m/s, ΔH ≈ 1318 × 2 ÷ 9.81 ≈ 269 m (about 2640 kPa). With L = 1000 m, Tc ≈ 1.52 s; if T = 20 s, ΔH ≈ 269 × 1.52 ÷ 20 ≈ 20 m.
Max pressure (pump outlet)
Max pressure = operating slurry head + ΔH
Min pressure (pump outlet)
Min pressure = operating slurry head − ΔH
Shown in red when below 0.
Column separation warning
When the minimum pressure is below 0, “Min pressure below 0: column separation may occur; consider air valves or surge protection.” is shown.
Note: The above is an engineering upper-bound estimate; actual behavior depends on check valves, pipeline elevation profile and so on. For important projects, perform a dedicated transient analysis.
Comparison tab
Add to comparison
After adjusting parameters, click “Add to comparison” at the top right to save the current result as a scenario (message “Added to comparison”); the tab name shows the number of scenarios, “Comparison (n)”. When there are no scenarios, the tab shows “After adjusting parameters, click “Add to comparison” at the top right to compare scenarios side by side here.”
Comparison table
Column · Meaning
Case · Named automatically, e.g. “Speed 1450 · Valve Opening 60% · Impeller trim 95% · Wear (head decay) 10% · Parallel×2”, listing only parameters that differ from the defaults
Speed · The speed (or impeller diameter) of the scenario
Flow, Slurry head · Operating point
Eff % · Efficiency per pump
Total power kW · Total
%BEP · Same coloring rules as the speed control table
NPSH margin · NPSHa − NPSHr
The ✕ at the end of each row deletes that scenario. Scenarios are kept only in the current page and are cleared on refresh.
Export and print
Export CSV
Downloads “simulation-SIZE.csv” (SIZE being the pump size; UTF-8, opens directly in Excel), containing in order:
1. The title row (Duty Simulation, pump size, curve name) and the speed;
2. Operating point: flow, slurry head, efficiency, total power, NPSHr, NPSHa, %BEP;
3. Point-by-point data of the pump curve at the current speed: flow, Pump (slurry), efficiency, Shaft power (per pump), NPSHr;
4. Point-by-point data of the system curve;
5. The speed control table.
Values are output in the current page units.
Print (simulation report)
Generates an A4 report and opens the print dialog (you can save as PDF); only the report is printed, not the interactive page. The report contains: operating point readings, operating parameters (only meaningful items), operating status and warnings, the Pump & System Curves chart, the performance curves chart, the speed control table, the multiple pumps table, the operating range table, the motor check, energy & cost, throttling vs VFD, pump-trip surge, the piping diagram and energy grade line, and the comparison. The footer states “Results are computed from the selected curve and the inputs; trim, wear, energy and surge values are engineering estimates for selection reference only.”