Energy Efficiency Grade

The page has two tabs, “Efficiency grade” and “Life Cycle Cost”. The “Efficiency grade” tab rates a pump from its flow, head, speed and efficiency at the best efficiency point, and gives two assessments:

Under the national standard GB 19762-2025 Minimum allowable values of energy efficiency and energy efficiency grades for centrifugal pumps, it assigns energy grade 1, 2 or 3, or shows that the pump is below the minimum allowable value.

Under the EU ecodesign regulation for water pumps, (EU) No 547/2012, it calculates the Minimum Efficiency Index MEI and checks whether MEI ≥ 0.40 is met.

The best efficiency point can be entered by hand, or taken directly from a curve. The page is in the left workspace panel under “Energy Efficiency Grade”.

Requirements and access

Requirements

Energy Efficiency Grade is a Premium feature, and members of an enterprise team can use it too. When a regular user opens it, the message ““Energy Efficiency Grade” is a Premium feature” and a “Get Premium” button are shown. See Premium membership.

How to open

Click “Energy Efficiency Grade” in the left workspace panel.

On a curve page, click “File → Energy efficiency grade”. This opens the page in a new window and automatically fills in the best efficiency point on the curve's nominal-speed line; the top of the page shows “Best efficiency point taken from curve "…"”. The curve must be your own private model, a curve you have purchased, or a free curve. For a curve you have not purchased, the message “This curve has not been purchased, so its best efficiency point can't be read. Please enter it manually.” is shown.

The page remembers the last standard, pump type and inputs, and restores them the next time it is opened.

Inputs

Standard

“GB 19762-2025”: the national standard; the result is energy grade 1 / 2 / 3.

“EU 547/2012”: the EU ecodesign regulation for water pumps; the result is the MEI value.

Pump type

For GB 19762-2025, the options are:

Pump type · Description

Single-stage end-suction clean water pump · Applicable flow 5–10 000 m³/h

Single-stage double-suction clean water pump · Applicable flow 50–20 000 m³/h; specific speed is calculated at half the flow

Inline clean water pump · Applicable flow 5–3 000 m³/h

Multistage clean water pump · Applicable flow 5–3 000 m³/h; specific speed is calculated from the head per stage

Light multistage clean water pump (vertical / horizontal) · Applicable flow 5–300 m³/h; vertical and horizontal pumps have different requirements

Single-stage end-suction petrochemical pump / Single-stage double-suction petrochemical pump · Pumps for clean liquids, closed impellers

Multistage petrochemical pump · Pumps for clean liquids, closed impellers

For EU 547/2012, the options are: ESOB end suction own bearing, ESCC end suction close coupled, ESCCi end suction close coupled inline, MS-V vertical multistage, and MSS submersible multistage (borehole).

Best efficiency point

Parameter · Unit · Description

Flow · m³/h · Flow at the best efficiency point. For double-suction pumps, enter the total flow

Head (total) · m · Head at the best efficiency point. For multistage pumps, enter the total head

Speed · r/min · Rated speed

Stages · — · Shown only for multistage pump types; 2–60

Pump efficiency · % · Tested efficiency at the best efficiency point

Efficiency at 75% flow · % · Shown only for EU 547/2012; may be left empty

Efficiency at 110% flow · % · Shown only for EU 547/2012; may be left empty

Use values measured at the full (maximum) impeller diameter and rated speed, tested to GB/T 3216 grade 2 (for EU 547/2012, clean cold water). Changing any input recalculates the results automatically.

Results

GB 19762-2025

The large heading shows “Grade 1”, “Grade 2”, “Grade 3”, or “Below grade 3 (under the minimum allowable value)”. Grade 3 is the minimum allowable value; a product below grade 3 does not comply with the standard.

Below it are listed the specific speed ns, the flow used (half the flow for double-suction pumps), the head per stage and the pump efficiency.

Petrochemical pumps additionally show the base efficiency ηb, the correction Δη and the specified point efficiency η0.

The grade table lists the minimum efficiency required for grades 1, 2 and 3, and whether it is achieved (✓ / ✗). A pump whose efficiency is not lower than a grade's requirement achieves that grade.

EU 547/2012

The large heading shows the MEI value, for example “MEI 0.43”. Above the highest band it shows “MEI >0.70”; below the lowest band it shows “MEI <0.10”.

The line below shows “Meets MEI ≥ 0.40” or “Does not meet MEI ≥ 0.40”. The regulation has required MEI ≥ 0.40 since 2015, and all three operating points must meet it.

“Constant table speed”: the regulation gives constants only for 1450 and 2900 r/min, and the one closer to the rated speed is used. MS-V and MSS have only the 2900 r/min constant.

“MEI set by”: when the efficiencies at 75% and 110% flow are entered, MEI is taken from the lowest of the three points, and this shows which point it is.

The MEI table lists the minimum efficiency required for each band from 0.10 to 0.70. The second table lists, for the best efficiency point, part load 75% and overload 110%, the requirement at MEI 0.40 and the actual efficiency.

Messages

Below the result, the following messages may appear. The result is still given, but for reference only:

Message · Meaning

Flow is outside the standard's range for this pump type · The flow is not within the applicable range in the table above

Specific speed is outside the standard's range · Petrochemical pumps: specific speed not in 20–300; EU end-suction pumps: not in 6–80

Head is outside the EU regulation's range for this speed · At 1450 r/min, single-stage head above 90 m; at 2900 r/min, above 140 m

Multistage pump stages calculated as 2 · A multistage type is selected but the stages are entered as 1

Only the 2900 r/min constant exists for this pump type · MS-V / MSS: the rated speed differs considerably from 2900

Part-load / overload efficiency not entered · MEI is evaluated at the best efficiency point only

Printing

Click “Print” in the upper right corner of the result card to generate an A4 report with the input parameters, specific speed, results and the required efficiency table for each grade.

Notes

Results are calculated from the data entered and are for design and selection reference only. Official energy-label filing and certification are based on tests carried out by a qualified testing body to the standard.

The best efficiency point taken from a curve comes from the curve's nominal-speed line. If the curve itself contains estimated data (marked “Partly estimated” on the curve page), the reliability of the result is reduced accordingly.

Life Cycle Cost

The “Life Cycle Cost” tab compares 1–4 options by their total cost over the service life (present value), following the cost structure in Pump Life Cycle Costs by Europump and the Hydraulic Institute. It is used in tenders to show how long the extra investment in a high-efficiency pump or a variable-speed option takes to pay back.

Opening this tab

On the Energy Efficiency Grade page, switch to the “Life Cycle Cost” tab.

Under the readings in the “Motor & energy” tab of Duty Simulation, click “Life Cycle Cost →”. The electrical power at the current duty is brought in as the “Average input power” of the first option.

Assumptions

Parameter · Description

Service life · 1–50 years

Electricity price · Price per kWh

Energy price rise per year · Annual percentage increase in energy cost

Other cost rise per year · Annual percentage increase in operating, maintenance, spare-parts and downtime costs

Discount rate · Percentage used to convert each year's cost to present value; enter 0 for no discounting

Currency · Display only, e.g. ¥, $, €

Options

Each option is one column. Click “Add option” to add up to four; column names can be changed. Each option requires:

Parameter · Description

Purchase (pump set) · Price of the pump, motor, baseplate, variable-speed drive, etc.

Installation & commissioning · One-time cost

Average input power · kW, at the motor input (including motor and drive losses)

Operating hours per year · 0–8784 h

Operating, maintenance and spare-parts costs per year · Annual costs

Overhaul cost, overhaul interval · One overhaul every few years; none is counted in the final year

Downtime hours per year, downtime loss per hour · Losses from unplanned downtime

End-of-life disposal (negative = residual value) · Dismantling and disposal cost; enter a negative value if there is residual value

Reading the results

“Lowest life cycle cost: …”: the option with the lowest total present value.

Present-value table: the present value of each cost item (Purchase, Installation, Energy, Operation, Maintenance & overhaul, Spare parts, Downtime loss, Disposal) and the total “Life Cycle Cost”, plus the energy share and the energy used per year in kWh.

“Saving vs. first option”: the first option's life cycle cost minus this option's.

“Payback of extra investment”: when this option's initial cost is higher than the first option's, the number of years until its cumulative cost falls below that of the first option. “No payback” is shown if it never does.

“Cumulative cost (present value)” chart: for each option, the cumulative present-value curve from year 0 (purchase + installation) to the final year. The crossing points are the payback points.

Energy usually accounts for most of a pump's life cycle cost, so a few percentage points of efficiency often pay off more than a lower purchase price.