PUMPVIZ 3.1.4 released: Motor Selection & Analysis added, private models can be recognized from PDF, AI assistant Xiaorui is online

PUMPVIZ 3.1.4 is now available. This release adds Motor Selection & Analysis, and also makes improvements in two areas for pump manufacturers: entering their own product data more efficiently, and presenting it to customers more clearly.

1. Motor Selection & Analysis

A “Motor Selection & Analysis” entry is added to the workspace on the left. Starting from the pump’s shaft power and speed, it works through the motor questions in one go:

  • Recommendation: recommends a motor power step (0.12–1000 kW) from the duty shaft power, maximum shaft power and margin factor, and lists speed matching for 2, 4, 6 and 8 poles. For direct coupling, belt drive, gearbox and VFD, it gives the speed deviation, transmission ratio or VFD frequency respectively. With a VFD running at reduced speed, the motor is selected by torque, avoiding overload at low speed. Available to all signed-in users.
  • Motor Characteristics: efficiency values are taken from the IEC 60034-30-1 IE1–IE4 efficiency classes. For 50 Hz and 60 Hz motors, each uses its own efficiency table for values and class. View how efficiency, power factor, current and speed change with load, as well as the torque and current against speed curves.
  • Operating Analysis: gives the motor load ratio, efficiency, power factor and current, with the efficiency chain calculated through to the overall unit efficiency. Calculates annual electricity consumption, energy cost and CO₂ emissions, and checks whether the motor is overloaded across the full flow range. Compares annual energy cost and savings over the service life for IE1–IE4 at the same power.
  • Starting Check: compares starting time, starting current, acceleration margin and rotor heating for direct-on-line, star-delta, soft starter and VFD starting. Entering the transformer capacity also estimates the grid voltage drop during starting, and judges whether the motor can start at the actual voltage after the dip.
  • My Motor Library: enter the motor manufacturer’s catalogue parameters and measured load points, and calculations use the measured data. Supports batch import by table (recognizes common notations such as decimal commas and units) and export, is shared within the enterprise team, and on phones the library is shown and edited as cards.
  • Linked with simulation and filter: in Duty Simulation, “Motor & energy” can be set to “Per motor”, so motor efficiency changes with load ratio and the motor’s allowable power is shown as a dashed line on the power chart (manual motor efficiency entry remains the default). In filter step 5, the new “Select motor” button fills in the motor model, power and speed in one click. It also works for private models, and power can be entered manually when no shaft power is available. Customers of the enterprise selection portal can also use “Select motor”.

Motor Characteristics, Operating Analysis, Starting Check and My Motor Library are Premium member features, and enterprise team members can use them too.

2. Private models: recognize curves from PDF

Private models now include “Import from PDF”. Upload a curve PDF from the manufacturer’s catalogue (vector format, up to 5MB), and the system automatically completes the following:

  • Curve extraction: recognizes speed lines, iso-efficiency lines, NPSHr lines and best efficiency point lines, together with the values labelled on the chart.
  • Axes and units: automatically calibrates the axes and determines the flow and head units.
  • Overlay check: recognition results are overlaid on the original image, with the grid and plot frame aligned to the original, so each line can be checked and corrected.
  • Curve generation: converts the results into a multi-speed test table, with complete efficiency and NPSHr data for every speed line, keeping the iso-line levels of the original chart.
  • Header parameters: reads the impeller diameter, number of vanes, minimum passage size, suction and discharge sizes and materials where they appear on the chart. Tick the ones you want, and they fill the empty fields in the structural parameters.
  • Xiaorui assistance: where a label does not match a line, Xiaorui can help complete it.

Image recognition cannot guarantee 100% accuracy, so please check each line before saving. The user guide has a new section, “What to do if recognition is inaccurate”.

3. Private models: nameplate specifications and filter calculation data

  • Nameplate specifications: enter the impeller type, seal type, part numbers and materials, frame (with rated power) and liner (with maximum rated speed). They are shown in the specifications bar on the curve page. For private models with this data, the filter also checks the liner speed and frame power.
  • Advanced filter calculation data: enter bearing assemblies (shaft, bearing model and quantity, shaft diameter for each section), auxiliary impellers, allowable flange loads, the casing pressure table and impeller mass parameters. Once filled in, private models can also calculate bearing life, critical speed, centrifugal seal pressure and flange loads in the filter, using the same methods as the system curves.
  • Bulk import: the template adds columns for all of the above, so they can be imported in one pass.
  • Mobile entry: the private model edit page no longer needs horizontal scrolling on phones.

4. AI assistant “Xiaorui”

A new “Ask Xiaorui” panel on the right side of the page lets you ask about using the platform in natural language, for example “How do I fill in step 2 of the filter?” or “How do I import private curves?” Xiaorui answers based on the user guide, replies in the current interface language, and attaches links to the relevant guide sections. Answers appear as they are generated, so there is no need to wait. Available after signing in.

5. Curve reports and watermark

  • Custom report logo: Premium members can replace the logo on curve reports with their own. In an enterprise team, the owner sets it once, and the reports seen by customers of the selection portal use the same logo.
  • Copyright line: when a text watermark is set, the copyright line of the report shows that text.
  • Report layout: the vertical axis is labelled “Head (m)”. Printing is fixed to a single page, and longer foreign-language notes no longer push the curve onto a second page.

6. Enterprise team and selection portal

  • Mobile app screen orientation: when packaging the mobile app, you can choose to follow the phone, force landscape or force portrait. You can also enable “Desktop layout in landscape”, which shows the same full interface as on a computer.
  • iOS installation package: the iOS version now provides an installation package directly. The company can sign it with its own Apple developer certificate and distribute it. Those who want to publish to the App Store can still use the bundled project files.
  • Portal on mobile: the curve page has a back button. Double-tap a result to open its curve; after a search, the list scrolls to the results automatically. Returning to the search page keeps the previous results, the selected row and the scroll position.
  • Portal desktop app: opening a curve pops up a separate window. In a small window, the curve and specifications are still displayed side by side.
  • Portal details: the browser tab title uses the company’s site name. Before the portal address suffix is changed, a warning reminds you that old links and already packaged apps will stop working. When binding your own domain, the DNS record instructions are clearer, and a hint shows the correct format if an entry is wrong.
  • Team permissions: hydraulic design schemes now have two separate permissions (create and edit one’s own schemes; edit and delete teammates’ schemes), which can be assigned independently of the private model permissions.

7. Naming changes in the system curve library

This version unifies the naming conventions of the system curve library:

  • Curve IDs: a prefix is added uniformly, “PU-” by default, for example PU-ESY8673.
  • Models and part numbers: the technical code “PU” in model names and in impeller and auxiliary impeller part numbers is now unified, for example 14/12 AH-PU and G12145PU1.
  • Material names: high-chrome alloy materials now use a common generic name, for example High Chrome 27% Cr. Material codes are unchanged.
  • Custom prefix: Premium members can change the prefix to their own under “My Account” (1–6 letters or digits). In an enterprise team, the owner sets it for the whole team, and customers of the selection portal see the prefix set by the enterprise. If no prefix is set, the platform default prefix is used.

Searching with either the new or the original ID finds the curve. Purchased curves, project selections saved in projects and enquiry records also show the new names; purchase records, curve data and calculation results are not affected.

8. Other improvements

  • Registration and password reset now require the password to be entered twice; a mismatch is flagged immediately.
  • The curve chart redraws automatically when the window is resized, so it displays fully even in a small desktop window.

9. User guide

The user guide adds “Motor Selection & Analysis”, “Import from PDF” and “What to do if recognition is inaccurate”. Chapters on Duty Simulation, private models, bulk import, the filter and the selection portal are updated as well, and are available in 11 languages.

Thank you to all users for your support and suggestions. We welcome you to try PUMPVIZ 3.1.4. For any questions or suggestions, please tell us via “Feedback” or the contact details on the site.

Loading... If the page does not appear, please make sure JavaScript is enabled in your browser.